Objective: The purpose of this study was to evaluate the accuracy of the inter-arch relationship of digital models generated using two types of intraoral scanners. Methods: In total, 34 plaster model samples were used. Two corresponding digital models were created using two types of intraoral scanners. A total of 15 variables were measured. The plaster model was directly measured using a digital caliper, while the digital models were measured using a software. The accuracy of the measurements was evaluated using repeated measures analysis of variance and the Friedman test. Results: Among the 15 measurements, 6 measurements[Overjet, Overbite, DZ_11-41 (Distance between the gingival zenith of maxillary right central incisor and mandibular right central incisor), DZ_16-46 (Distance between the gingival zenith of maxillary right first molar and mandibular right first molar), DZ_13-33 (Distance between the gingival zenith of maxillary right canine and mandibular left canine), and DZ_23-43 (Distance between the gingival zenith of maxillary left canine and mandibular right canine)]showed statistically significant differences, with DZ_23-43 showing the largest difference of 0.18 mm. The other measurements showed no statistically significant differences. Conclusions: Regardless of the type of scanner used for preparation, digital models can be used as clinically acceptable alternatives to conventional plaster models.

Abstract

Objective: The purpose of this study was to evaluate the accuracy of the inter-arch relationship of digital models generated using two types of intraoral scanners. Methods: In total, 34 plaster model samples were used. Two corresponding digital models were created using two types of intraoral scanners. A total of 15 variables were measured. The plaster model was directly measured using a digital caliper, while the digital models were measured using a software. The accuracy of the measurements was evaluated using repeated measures analysis of variance and the Friedman test. Results: Among the 15 measurements, 6 measurements[Overjet, Overbite, DZ_11-41 (Distance between the gingival zenith of maxillary right central incisor and mandibular right central incisor), DZ_16-46 (Distance between the gingival zenith of maxillary right first molar and mandibular right first molar), DZ_13-33 (Distance between the gingival zenith of maxillary right canine and mandibular left canine), and DZ_23-43 (Distance between the gingival zenith of maxillary left canine and mandibular right canine)]showed statistically significant differences, with DZ_23-43 showing the largest difference of 0.18 mm. The other measurements showed no statistically significant differences. Conclusions: Regardless of the type of scanner used for preparation, digital models can be used as clinically acceptable alternatives to conventional plaster models.

참고문헌 (26)

  1. Horton HM, "Technique comparison for efficient orthodontic tooth measurements using digital models", Angle Orthod, 80, pp.254~261 (2010)
  2. Pacheco-Pereira C, "Variation of orthodontic treatment decision-making based on dental model type : A systematic review", Angle Orthod, 85, pp.501~509 (2015)
  3. Reuschl RP, "Reliability and validity of measurements on digital study models and plaster models", Eur J Orthod, 38, pp.22~26 (2016)
  4. Sweeney S, "Comparison of 5 types of interocclusal recording materials on the accuracy of articulation of digital models", Am J Orthod Dentofacial Orthop, 148, pp.245~252 (2015)
  5. Kihara T, "Accuracy of a three-dimensional dentition model digitized from an interocclusal record using a non-contact surface scanner", Eur J Orthod, 38, pp.435~439 (2016)
  6. Aragon ML, "Validity and reliability of intraoral scanners compared to conventional gypsum models measurements : a systematic review", Eur J Orthod, 38, pp.429~434 (2016)
  7. Fleming PS, "Orthodontic measurements on digital study models compared with plaster models : a systematic review", Orthod Craniofac Res, 14, pp.1~16 (2011)
  8. Kim J, "Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography", Angle Orthod, 84, pp.443~450 (2014)
  9. Burzynski JA, "Comparison of digital intraoral scanners and alginate impressions : Time and patient satisfaction", Am J Orthod Dentofacial Orthop, 153, pp.534~541 (2018)
  10. Grewal B, "Royal London space analysis : plaster versus digital model assessment", Eur J Orthod, 39, pp.320~325 (2017)
  11. Goracci C, "Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence", Eur J Orthod, 38, pp.422~428 (2016)
  12. Ji-won Anh, "A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction", 대한치과교정학회지, 46(1), pp.3~12 (2016), 대한치과교정학회
  13. Cuperus AM, "Dental models made with an intraoral scanner : a validation study", Am J Orthod Dentofacial Orthop, 142, pp.308~313 (2012)
  14. Darroudi AM, "Accuracy of a computed tomography scanning procedure to manufacture digital models", Am J Orthod Dentofacial Orthop, 151, pp.995~1003 (2017)
  15. Kiviahde H, "Inter-arch digital model vs. manual cast measurements: Accuracy and reliability", Cranio, 36, pp.222~227 (2018)
  16. Wan Hassan WN, "Assessing agreement in measurements of orthodontic study models : Digital caliper on plaster models vs 3-dimensional software on models scanned by structured-light scanner", Am J Orthod Dentofacial Orthop, 150, pp.886~895 (2016)
  17. Mack S, "Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners", Am J Orthod Dentofacial Orthop, 152, pp.420~425 (2017)
  18. Yoon JH, "Model Analysis of Digital Models in Moderate to Severe Crowding : In Vivo Validation and Clinical Application", Biomed Res Int, 2018, pp.8414605~ (2018)
  19. Koretsi V, "Intra-observer reliability and agreement of manual and digital orthodontic model analysis", Eur J Orthod, 40, pp.52~57 (2018)
  20. Reuschl RP, "Reliability and validity of measurements on digital study models and plaster models", Eur J Orthod, 38, pp.22~26 (2016)
  21. Dahlberg G, "Statistical methods for medical and biological students" (1940), Interscience Publications
  22. Bland JM, "Measuring agreement in method comparison studies", Stat Methods Med Res, 8, pp.135~160 (1999)
  23. Rossini G, "Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes : A systematic review", Am J Orthod Dentofacial Orthop, 149, pp.161~170 (2016)
  24. Porter JL, "Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation", J Orthod, 45, pp.275~282 (2018)
  25. Kong KA, "Statistical methods : reliability assessment and method comparison", Ewha Med J, 40, pp.9~16 (2017)
  26. 윤달선, "Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study", 대한치과교정학회지, 48(4), pp.262~267 (2018), 대한치과교정학회

관련 논문AI추천

Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scannersAnne Marie Kuijpers-Jagtman, Edwin M. Ongkosuwito, E. Willemijn Penning, K. Hero Breuning, Leonardo T. Camardella, Oswaldo V. Vilella대한치과교정학회 · 대한치과교정학회지2020 · 제50권 제1호Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differencesChoi Won-joon, Lee Su-jung, Moon Cheol-Hyun대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제1호Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods김소연, 이규복, 이근우, 이두형, 이재목, 이청희, 마이항나, Hai Yen Mai대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제2호A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot studyEneko Solaberrieta, Erlantz Lizundia, Mikel Iturrate, Xabier Amezua대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제6호Effect of different arch widths on the accuracy of three intraoral scannersChakree Ongthiemsak, Narin Kaewbuasa대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제4호Effect of the volumetric dimensions of a complete arch on the accuracy of scanners김민규, 유범영, 이규복, 손큰바다대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호