본문 바로가기
KERD
논문KCI 등재

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians’ ability to measure the printed models. Methods: Twenty sets of patients’ plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23–#33 (DZL_3) for the plaster models and at #17–#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17–#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

Abstract

Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians’ ability to measure the printed models. Methods: Twenty sets of patients’ plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23–#33 (DZL_3) for the plaster models and at #17–#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17–#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

참고문헌 (32)

  1. Bell A, "Assessment of the accuracy of a three-dimensional imaging system for archiving dental study models", J Orthod, 30, pp.219~223 (2003)
  2. Council of Faculty of Orthodontics, "Textbook of orthodontics", pp.170~172 (2006), DaehanNarae Publishing Inc
  3. Fleming PS, "Orthodontic measurements on digital study models compared with plaster models : a systematic review", Orthod Craniofac Res, 14, pp.1~16 (2011)
  4. Stevens DR, "Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements", Am J Orthod Dentofacial Orthop, 129, pp.794~803 (2006)
  5. "Enforcement Regulation of the Medical Law, Korea. Article 15" (2016)[URL]
  6. "Legal advice no. 324, 492" (2018)[URL]
  7. Mizrahi E, "Risk management in clinical practice. Part 7. Dento-legal aspects of orthodontic practice", Br Dent J, 209, pp.381~390 (2010)
  8. Charangowda BK, "Dental records : an overview", J Forensic Dent Sci, 2, pp.5~10 (2010)
  9. Wiranto MG, "Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions", Am J Orthod Dentofacial Orthop, 143, pp.140~147 (2013)
  10. Hazeveld A, "Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques", Am J Orthod Dentofacial Orthop, 145, pp.108~115 (2014)
  11. Wan Hassan WN, "Comparison of reconstructed rapid prototyping models produced by 3-dimensional printing and conventional stone models with different degrees of crowding", Am J Orthod Dentofacial Orthop, 151, pp.209~218 (2017)
  12. Camardella LT, "Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases", Am J Orthod Dentofacial Orthop, 151, pp.1178~1187 (2017)
  13. Yourtee D, "Stereolithographic models of biopolymers", J Mol Graph Model, 18, pp.26~28 (2000)
  14. Raju BS, "Determining the influence of layer thickness for rapid prototyping with Stereolithography(SLA)process", Int J Eng Sci Technol, 2, pp.3199~3205 (2010)
  15. Cuperus AM, "Dental models made with an intraoral scanner : a validation study", Am J Orthod Dentofacial Orthop, 142, pp.308~313 (2012)
  16. Brown GB, "Accuracy of 3-dimensional printed dental models reconstructed from digital intraoral impressions", Am J Orthod Dentofacial Orthop, 154, pp.733~739 (2018)
  17. Ji-won Anh, "A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction", 대한치과교정학회지, 46(1), pp.3~12 (2016), 대한치과교정학회
  18. Loflin WA, "Effect of print layer height on the assessment of 3D-printed models", Am J Orthod Dentofacial Orthop, 156, pp.283~289 (2019)
  19. Naidu D, "Validity, reliability, and reproducibility of the iOC intraoral scanner: a comparison of tooth widths and Bolton ratios", Am J Orthod Dentofacial Orthop, 144, pp.304~310 (2013)
  20. Darroudi AM, "Accuracy of a computed tomography scanning procedure to manufacture digital models", Am J Orthod Dentofacial Orthop, 151, pp.995~1003 (2017)
  21. Leonardo T. Camardella, "Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners", 대한치과교정학회지, 50(1), pp.13~25 (2020), 대한치과교정학회[DOI]
  22. Porter JL, "Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation", J Orthod, 45, pp.275~282 (2018)
  23. 유조광, "Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study", 대한치과의사협회지, 58(4), pp.194~205 (2020), 대한치과의사협회[DOI]
  24. Wesemann C, "Accuracy and efficiency of full-arch digitalization and 3D printing: a comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing", Quintessence Int, 48, pp.41~50 (2017)
  25. Saleh WK, "Accuracy and reproducibility of linear measurements of resin, plaster, digital and printed study-models", J Orthod, 42, pp.301~306 (2015)
  26. Hayashi K, "Assessment of the accuracy and reliability of new 3-dimensional scanning devices", Am J Orthod Dentofacial Orthop, 144, pp.619~625 (2013)
  27. Sherman SL, "Accuracy of digital light processing printing of 3-dimensional dental models", Am J Orthod Dentofacial Orthop, 157, pp.422~428 (2020)
  28. "Digital model and 3D printing requirements" (2016)[URL]
  29. Camardella LT, "Accuracy of stereolithographically printed digital models compared to plaster models", J Orofac Orthop, 78, pp.394~402 (2017)
  30. Rebong RE, "Accuracy of three-dimensional dental resin models created by fused deposition modeling, stereolithography, and Polyjet prototype technologies: a comparative study", Angle Orthod, 88, pp.363~369 (2018)
  31. Reuschl RP, "Reliability and validity of measurements on digital study models and plaster models", Eur J Orthod, 38, pp.22~26 (2016)
  32. Westerlund A, "Digital casts in orthodontics : a comparison of 4 software systems", Am J Orthod Dentofacial Orthop, 147, pp.509~516 (2015)

관련 논문AI추천

Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study김성훈, 문철현, 유조광, Su-Jung Lee, Yoon-Koo Kang대한치과의사협회 · 대한치과의사협회지2020 · 제58권 제4호Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition김미선, 남옥형, 신서영, 이고은, 이효설, 채용권, 최성철대한소아치과학회 · 대한소아치과학회지2024 · 제51권 제1호Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scannersAnne Marie Kuijpers-Jagtman, Edwin M. Ongkosuwito, E. Willemijn Penning, K. Hero Breuning, Leonardo T. Camardella, Oswaldo V. Vilella대한치과교정학회 · 대한치과교정학회지2020 · 제50권 제1호Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique김기백, 김웅철, 김재홍, 김지환, 김혜영대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제2호Evaluation of the accuracy of a 3D-printed palatal auxiliary device for maxillary protraction after palatal expansionFu Ping Cui, Hwarang Jeong, Jin-Hwan Kim, Jung-Jin Park, Seong-Hun Kim, Sue Yeon Lee대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제4호Accuracy of three-dimensional printing for manufacturing replica teeth강경화, 김상철, 장나영, 조진형, 채종문, Jin-Woo Cho, Keun-Young Lee대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제5호

이 간행물의 다른 논문 (7건)