본문 바로가기
KERD
논문KCI 등재

Iterative finite element analysis of clear aligner-induced bodily canine movement under alveolar bone loss conditions

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: This study aimed to evaluate the long-term biomechanical effects of alveolar bone loss on 0.25-mm canine bodily movement using a clear aligner (CA) through iterative finite element analysis (FEA). Methods: Three-dimensional maxillary models with normal bone height, 2-mm bone loss, and 4-mm bone loss were constructed. An iterative FEA approach was applied to a single CA designed for 0.25 mm of planned distal movement, with biomechanical responses calculated throughout 50 sequential stages to simulate progressive tooth displacement. All components (maxilla, teeth, periodontal ligament, and CA) were assigned linear elastic properties. At each iterative stage, the forces, moments, crown displacement, tipping, rotation, and moment-to-force (M/F) ratios were analyzed. Results: Alveolar bone loss produced lower initial forces but increased initial crown displacement and tipping. Forces declined rapidly after the initial stages and stabilized at a level below 1 N. Tipping peaked early and gradually decreased, with the largest reduction observed in the severe bone loss group. The M/F ratio increased after the early stages and maintained values above 10 across all groups, thereby promoting controlled bodily movement. Final crown displacement was greatest in the normal bone group, while overall rotation remained minimal and clinically insignificant. Conclusions: Iterative FEA demonstrated that CAs produced lower forces and higher M/F ratios under periodontally compromised conditions, supporting controlled bodily movement. However, the observed excessive initial displacement underscores the need for careful clinical management to optimize outcomes.

Abstract

Objective: This study aimed to evaluate the long-term biomechanical effects of alveolar bone loss on 0.25-mm canine bodily movement using a clear aligner (CA) through iterative finite element analysis (FEA). Methods: Three-dimensional maxillary models with normal bone height, 2-mm bone loss, and 4-mm bone loss were constructed. An iterative FEA approach was applied to a single CA designed for 0.25 mm of planned distal movement, with biomechanical responses calculated throughout 50 sequential stages to simulate progressive tooth displacement. All components (maxilla, teeth, periodontal ligament, and CA) were assigned linear elastic properties. At each iterative stage, the forces, moments, crown displacement, tipping, rotation, and moment-to-force (M/F) ratios were analyzed. Results: Alveolar bone loss produced lower initial forces but increased initial crown displacement and tipping. Forces declined rapidly after the initial stages and stabilized at a level below 1 N. Tipping peaked early and gradually decreased, with the largest reduction observed in the severe bone loss group. The M/F ratio increased after the early stages and maintained values above 10 across all groups, thereby promoting controlled bodily movement. Final crown displacement was greatest in the normal bone group, while overall rotation remained minimal and clinically insignificant. Conclusions: Iterative FEA demonstrated that CAs produced lower forces and higher M/F ratios under periodontally compromised conditions, supporting controlled bodily movement. However, the observed excessive initial displacement underscores the need for careful clinical management to optimize outcomes.

관련 논문AI추천

Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extractionKi Beom Kim, Kiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Evaluation of the effect of attachments on torque control of palatally positioned maxillary lateral teeth with clear aligners: Finite element analysisIrmak Ocak, Nurver Karsli, Ömür Polat Özsoy, Sevil Gökcek대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제1호Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study김용일, Choi Youn-Kyung, Kim Ki Beom, Kim Sung-Hun, Ko Ching-Chang, Oh Sewoong대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제6호En masse maxillary dentition distalization with clear aligners using infrazygomatic mini-implants: A finite element studyAllahyar Geramy, Joseph Bouserhal, Lina Medawar, Nayla Bassil Nassif, Nicolas Nassar, Patrick Sayegh, Roland Kmeid대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation methodJong-Chan Baik, Ki Beom Kim, Seong-Sik Kim, Soo-Byung Park, Sung-Hun Kim, Yonghun Cho, Yong-Il Kim, Youn-Kyung Choi, Yunju Baek대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제6호Effect of labiolingual inclination of a maxillary central incisor and surrounding alveolar bone loss on periodontal stress: A finite element analysisChung-Ju Hwang, Kee-Joon Lee, Sung-Hwan Choi, Young-Hoon Kim대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제3호

이 간행물의 다른 논문 (6건)