본문 바로가기
KERD
논문KCI 등재

En masse maxillary dentition distalization with clear aligners using infrazygomatic mini-implants: A finite element study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: Considering the success of infrazygomatic mini-implants in conjunction with traditional braces, this study aimed to evaluate the efficacy of infrazygomatic mini-implants in en masse maxillary distalization utilizing clear aligner therapy. Methods: In a three-dimensional finite element study, we evaluated the en masse maxillary dental distalization through the use of infrazygomatic mini-implants equipped with varying force-application arm lengths (0 mm, 4 mm, and 8 mm). Vertical, sagittal, and horizontal displacements were quantified. Results: Intrusion was observed in the incisors at all force application arm lengths (0 mm, 4 mm, and 8 mm), with similar sagittal displacement tendencies and labial crown tipping. Among all maxillary teeth, only the canine exhibited distalization of both the crown and root. Distalization of the posterior teeth was achieved, with the greatest magnitude of distalization occurring at the 0-mm force application arm length, which was characterized by minimal tipping and reduced vertical movements compared to the other force application arm lengths. Conclusions: The findings indicate that infrazygomatic mini-implants represent a viable approach for facilitating targeted tooth movement in clear aligners across various force-application arm lengths. These results may inform orthodontic treatment strategies in non-extraction cases.

Abstract

Objective: Considering the success of infrazygomatic mini-implants in conjunction with traditional braces, this study aimed to evaluate the efficacy of infrazygomatic mini-implants in en masse maxillary distalization utilizing clear aligner therapy. Methods: In a three-dimensional finite element study, we evaluated the en masse maxillary dental distalization through the use of infrazygomatic mini-implants equipped with varying force-application arm lengths (0 mm, 4 mm, and 8 mm). Vertical, sagittal, and horizontal displacements were quantified. Results: Intrusion was observed in the incisors at all force application arm lengths (0 mm, 4 mm, and 8 mm), with similar sagittal displacement tendencies and labial crown tipping. Among all maxillary teeth, only the canine exhibited distalization of both the crown and root. Distalization of the posterior teeth was achieved, with the greatest magnitude of distalization occurring at the 0-mm force application arm length, which was characterized by minimal tipping and reduced vertical movements compared to the other force application arm lengths. Conclusions: The findings indicate that infrazygomatic mini-implants represent a viable approach for facilitating targeted tooth movement in clear aligners across various force-application arm lengths. These results may inform orthodontic treatment strategies in non-extraction cases.

관련 논문AI추천

Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study김용일, Choi Youn-Kyung, Kim Ki Beom, Kim Sung-Hun, Ko Ching-Chang, Oh Sewoong대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제6호Evaluation of the effects of the third molar on distalization and the effects of attachments on distalization and expansion with clear aligners: Three-dimensional finite element studyAslihan Kuguoglu, Bengisu Akarsu-Guven대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제1호Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position모성서, Jae-Won Song, Joong-Ki Lim, Kee-Joon Lee, Sang-Jin Sung, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호Distalization pattern of whole maxillary dentition according to force application points김성진, 박영철, 유형석, 이기준, 전윤식, Eui-Hyang Sung대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제1호Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extractionKi Beom Kim, Kiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Iterative finite element analysis of clear aligner-induced bodily canine movement under alveolar bone loss conditionsKiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제6호

이 간행물의 다른 논문 (8건)