Objective: Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction. Methods: FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method. Results: All the groups initially showed crown displacement, distal tipping, and distal rotation. Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%. Conclusions: The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.

Abstract

Objective: Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction. Methods: FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method. Results: All the groups initially showed crown displacement, distal tipping, and distal rotation. Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%. Conclusions: The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.

관련 논문AI추천

Iterative finite element analysis of clear aligner-induced bodily canine movement under alveolar bone loss conditionsKiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제6호Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study김용일, Choi Youn-Kyung, Kim Ki Beom, Kim Sung-Hun, Ko Ching-Chang, Oh Sewoong대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제6호In vitro analysis of mandibular arch response to canine distalization with aligners at varying initial angulationsAn Le, Fan Yongjie, Guo Baoxiong, Liu Gebing, Lv Xin, Wang Bingle, Yang Sensen대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제4호En masse maxillary dentition distalization with clear aligners using infrazygomatic mini-implants: A finite element studyAllahyar Geramy, Joseph Bouserhal, Lina Medawar, Nayla Bassil Nassif, Nicolas Nassar, Patrick Sayegh, Roland Kmeid대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Evaluation of the effects of the third molar on distalization and the effects of attachments on distalization and expansion with clear aligners: Three-dimensional finite element studyAslihan Kuguoglu, Bengisu Akarsu-Guven대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제1호Force changes associated with differential activation of en-masse retraction and/or intrusion with clear alignersShuo Li, Wei Hu, Ye Zhu대한치과교정학회 · 대한치과교정학회지2021 · 제51권 제1호

이 간행물의 다른 논문 (8건)