Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann–Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.
Abstract
Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann–Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.
참고문헌 (40)
- Bondemark L, "Long-term stability of orthodontic treatment and patient satisfaction. A systematic review", Angle Orthod, 77, pp.181~191 (2007)
- Littlewood SJ, "Retention procedures for stabilising tooth position after treatment with orthodontic braces", Cochrane Database Syst Rev, 2016, pp.CD002283~ (2016)
- Miyazaki H, "Occlusal stability after extraction orthodontic therapy in adult and adolescent patients", Am J Orthod Dentofacial Orthop, 114, pp.530~537 (1998)
- Ackerman MB, "Microsensor technology to help monitor removable appliance wear", Am J Orthod Dentofacial Orthop, 135, pp.549~551 (2009)
- Tsomos G, "Objective assessment of patient compliance with removable orthodontic appliances : a cross-sectional cohort study", Angle Orthod, 84, pp.56~61 (2014)
- Zotti F, "Implementing post-orthodontic compliance among adolescents wearing removable retainers through Whatsapp : a pilot study", Patient Prefer Adherence, 13, pp.609~615 (2019)
- El-Huni A, "Understanding factors influencing compliance with removable functional appliances : a qualitative study", Am J Orthod Dentofacial Orthop, 155, pp.173~181 (2019)
- Al-Moghrabi D, "Evaluation of the effectiveness of a tailored mobile application in increasing the duration of wear of thermoplastic retainers : a randomized controlled trial", Eur J Orthod, 42, pp.571~579 (2020)
- Ackerman MB, "Posttreatment compliance with removable maxillary retention in a teenage population: a short-term randomized clinical trial", Orthodontics (Chic.), 12, pp.22~27 (2011)
- Roisin LC, "Remotely-controlled orthodontics : fundamentals and description of the Dental Monitoring system", J Dentofacial Anom Orthod, 19, pp.408~ (2016)
- Morris RS, "Accuracy of Dental Monitoring 3D digital dental models using photograph and video mode", Am J Orthod Dentofacial Orthop, 156, pp.420~428 (2019)
- Moylan HB, "Accuracy of a smartphone-based orthodontic treatment-monitoring application : a pilot study", Angle Orthod, 89, pp.727~733 (2019)
- Caruso S, "A knowledge-based algorithm for automatic monitoring of orthodontic treatment: the Dental Monitoring system", Sensors(Basel), 21, pp.1856~ (2021)
- Giudice A, "Can teledentistry improve the monitoring of patients during the COVID-19 dissemination? A descriptive pilot study", Int J Environ Res Public Health, 17, pp.3399~ (2020)
- Bianco A, "COVID-19 and orthodontics : an approach for monitoring patients at home", Open Dent J, 15(Suppl 1), pp.87~96 (2021)
- Sangalli L, "Effects of remote digital monitoring on oral hygiene of orthodontic patients : a prospective study", BMC Oral Health, 21, pp.435~ (2021)
- Grünheid T, "How accurate is Invisalign in nonextraction cases? Are predicted tooth positions achieved?", Angle Orthod, 87, pp.809~815 (2017)
- Adamek A, "Intercanine widthreview of the literature", Dent Med Probl, 52, pp.336~340 (2015)
- Vaid NR, "Artificial Intelligence(AI)driven orthodontic care : a quest toward utopia?", Semin Orthod, 27, pp.57~61 (2021)
- Hansa I, "Artificial Intelligence Driven Remote Monitoring of orthodontic patients : clinical applicability and rationale", Semin Orthod, 27, pp.138~156 (2021)
- Hansa I, "Remote monitoring and “Tele-orthodontics”: concept, scope and applications", Semin Orthod, 24, pp.470~481 (2018)
- Dalessandri D, "Attitude towards telemonitoring in orthodontists and orthodontic patients", Dent J(Basel), 9, pp.47~ (2021)
- Vaid NR, "Smartphone applications used in orthodontics: a scoping review of scholarly literature", J World Fed Orthod, 9(3S), pp.S67~S73 (2020)
- Zotti F, "Usefulness of an app in improving oral hygiene compliance in adolescent orthodontic patients", Angle Orthod, 86, pp.101~107 (2016)
- Savoldi F, "Incisal apical root resorption evaluation after low-friction orthodontic treatment using twodimensional radiographic imaging and trigonometric correction", J Clin Diagn Res, 9, pp.ZC70~ZC74 (2015)
- Hansa I, "Clinical outcomes and patient perspectives of Dental Monitoring® GoLive®with Invisalign®-a retrospective cohort study", Prog Orthod, 21, pp.16~ (2020)
- Hansa I, "Outcomes of clear aligner treatment with and without Dental Monitoring : a retrospective cohort study", Am J Orthod Dentofacial Orthop, 159, pp.453~459 (2021)
- Kuriakose P, "The assessment of rapid palatal expansion using a remote monitoring software", J World Fed Orthod, 8, pp.165~170 (2019)
- Savoldi F, "Evaluation of rapid maxillary expansion through acoustic emission technique and relative soft tissue attenuation", J Mech Behav Biomed Mater, 65, pp.513~521 (2017)
- Impellizzeri A, "Dental Monitoring Application:it is a valid innovation in the Orthodontics Practice?", Clin Ter, 171, pp.e260~e267 (2020)
- Hannequin R, "Clinical follow-up of corticotomy-accelerated Invisalign orthodontic treatment with Dental Monitoring", Am J Orthod Dentofacial Orthop, 158, pp.878~888 (2020)
- Purssell E, "The Hawthorne effect on adherence to hand hygiene in patient care", J Hosp Infect, 106, pp.311~317 (2020)
- Al-Moghrabi D, "Development of 'My Retainers' mobile application : triangulation of two qualitative methods", J Dent, 94, pp.103281~ (2020)
- Shah N, "Compliance with removable orthodontic appliances", Evid Based Dent, 18, pp.105~106 (2017)
- Steinnes J, "Stability of orthodontic treatment outcome in relation to retention status : an 8-year follow-up", Am J Orthod Dentofacial Orthop, 151, pp.1027~1033 (2017)
- Başçiftçi FA, "Occlusal contacts with different retention procedures in 1-year follow-up period", Am J Orthod Dentofacial Orthop, 131, pp.357~362 (2007)
- Olive RJ, "A longitudinal index study of orthodontic stability and relapse", Aust Orthod J, 19, pp.47~55 (2003)
- Suri S, "Clinical orthodontic management during the COVID-19 pandemic", Angle Orthod, 90, pp.473~484 (2020)
- Torkan S, "Retention : taking a more active role", Br Dent J, 230, pp.731~738 (2021)
- Edwards JG, "A long-term prospective evaluation of the circumferential supracrestal fiberotomy in alleviating orthodontic relapse", Am J Orthod Dentofacial Orthop, 93, pp.380~387 (1988)
