Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study
0
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.[Korean J Orthod 2018;48(4):262-267]
Abstract
The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.[Korean J Orthod 2018;48(4):262-267]
참고문헌 (11)
- Ghafari J, "Misinterpreting growth and treatment outcome from serial cephalographs", Clin Orthod Res, 1, pp.102~106 (1998)[DOI]
- Santoro M, "Comparison of measurements made on digital and plaster models", Am J Orthod Dentofacial Orthop, 124, pp.101~105 (2003)[DOI]
- Cha BK, "Applications of three-dimensionally scanned models in orthodontics", Int J Comput Dent, 10, pp.41~52 (2007)
- 임미영, "석고 모형, 레이저 스캔 디지털 모형, 콘 빔 CT 영상 간의 모형 분석 계측치 비교", 대한치과교정학회지, 39(1), pp.6~17 (2009), 대한치과교정학회
- Cha BK, "Analysis of tooth movement in extraction cases using three-dimensional reverse engineering technology", Eur J Orthod, 29, pp.325~331 (2007)[DOI]
- 2.0.CO;2,
- Lee SJ, "Three-dimensional analysis of tooth movement after intrusion of a supraerupted molar using a mini-implant with partial-fixed orthodontic appliances", Angle Orthod, 83, pp.274~279 (2013)[DOI]
- Dler Ali, "Three-dimensional evaluation of tooth movement in Class II malocclusions treated without extraction by orthodontic mini-implant anchorage", 대한치과교정학회지, 46(5), pp.280~289 (2016), 대한치과교정학회
- Cuperus AM, "Dental models made with an intraoral scanner: a validation study", Am J Orthod Dentofacial Orthop, 142, pp.308~313 (2012)[DOI]
- Ji-won Anh, "A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction", 대한치과교정학회지, 46(1), pp.3~12 (2016), 대한치과교정학회
- Bonett DG, "Sample size requirements for estimating intraclass correlations with desired precision", Stat Med, 21, pp.1331~1335 (2002)[DOI]
