Objective: This pilot study aims to evaluate the clinical accuracy of Smart stereolithography (STL) files generated by the Dental Monitoring® (DM) system by comparing them with gold standard intraoral scans (IOSs). Methods: Seven aligner patients using the DM application were included. For each patient, Smart STL files generated from remote scans were superimposed onto IOSs using the best-fit algorithm in OnyxCeph software. Differences regarding inclination, angulation, rotation, buccal/lingual, mesial/distal, and intrusion/extrusion were quantified and statistically compared. Results: Statistically significant differences were observed in inclination, mesial/distal, and buccal/lingual movements, particularly in the posterior segments. However, all deviations remained within clinically acceptable thresholds for single aligner tooth movement. Conclusions: Despite minor deviations, Smart STL files generated by DM demonstrated sufficient accuracy for use in aligner planning and refinement. These findings highlight the potential of DM-generated Smart STL files for subsequent aligner treatment.

Abstract

Objective: This pilot study aims to evaluate the clinical accuracy of Smart stereolithography (STL) files generated by the Dental Monitoring® (DM) system by comparing them with gold standard intraoral scans (IOSs). Methods: Seven aligner patients using the DM application were included. For each patient, Smart STL files generated from remote scans were superimposed onto IOSs using the best-fit algorithm in OnyxCeph software. Differences regarding inclination, angulation, rotation, buccal/lingual, mesial/distal, and intrusion/extrusion were quantified and statistically compared. Results: Statistically significant differences were observed in inclination, mesial/distal, and buccal/lingual movements, particularly in the posterior segments. However, all deviations remained within clinically acceptable thresholds for single aligner tooth movement. Conclusions: Despite minor deviations, Smart STL files generated by DM demonstrated sufficient accuracy for use in aligner planning and refinement. These findings highlight the potential of DM-generated Smart STL files for subsequent aligner treatment.

관련 논문AI추천

Accuracy of orthodontic movements with 3D printed aligners: A prospective observational pilot studyAlessandra Campobasso, Anna De Mari, Filippo Forin Valvecchi, Giorgio Gastaldi, Giovanni Battista, Marco Migliorati, Paolo Pesce, Sara Drago, Tommaso Castroflorio대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제3호Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility studyBonetti Stefano, Dalessandri Domenico, Massetti Francesca, Sangalli Linda, Savoldi Fabio, Visconti Luca대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제2호교정용 브라켓과 호선이 구강 내 스캔 영상의 정확성에 미치는 영향: 예비연구노수지, 임원희대한치과의사협회 · 대한치과의사협회지2025 · 제63권 제3호Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study김성훈, 문철현, 유조광, Su-Jung Lee, Yoon-Koo Kang대한치과의사협회 · 대한치과의사협회지2020 · 제58권 제4호Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differencesChoi Won-joon, Lee Su-jung, Moon Cheol-Hyun대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제1호Comparison of dimensional accuracy between direct-printed and thermoformed alignersAndrew Hayes, Jin-Young Choi, Julie McCray, Ki Beom Kim, Nickolas Koenig, Patricia Schneider대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제4호

이 간행물의 다른 논문 (9건)