본문 바로가기
KERD
논문KCI 등재

Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with 0.7 μL of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media wasassessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (α=.05). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in μm) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

Abstract

PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with 0.7 μL of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media wasassessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (α=.05). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in μm) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

참고문헌 (20)

  1. Gracis S, "Internal vs. external connections for abutments", reconstructions: a systematic review, 2012, pp.23, 202~216
  2. 심혜원, "Long-term cumulative survival and mechanical complications of singletooth Ankylos Implants: focus on the abutment neck fractures", The Journal of Advanced of Prosthodontics, 7(6), pp.423~430 (2015), 대한치과보철학회[DOI]
  3. Binon PP, "Implants and components : entering the new millennium", Int J Oral Maxillofac Implants, 15, pp.76~94 (2000)
  4. Koutouzis T, "Placement of implants with platform-switched Morse taper connections with the implant-abutment interface at different levels in relation to the alveolar crest : a short-term(1-year)randomized prospective controlled clinical trial", Int J Oral Maxillofac Implants, 28, pp.1553~1563 (2013)
  5. Hakimeh Siadat, "Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and externalhex implant connections", The Journal of Advanced of Prosthodontics, 9(4), pp.271~277 (2017), 대한치과보철학회[DOI]
  6. 문승진, "Sinking and fit of abutment of locking taper implant system", The Journal of Advanced of Prosthodontics, 1(2), pp.97~101 (2009), 대한치과보철학회[DOI]
  7. Lee JH, "Axial displacements in external and internal implant-abutment connection", Clin Oral Implants Res, 25, pp.e83~9 (2014)
  8. Goodacre CJ, "Clinical complications of osseointegrated implants", J Prosthet Dent, 81, pp.537~552 (1999)
  9. Nakamura K, "Zirconia as a dental implant abutment material : a systematic review", Int J Prosthodont, 23, pp.299~309 (2010)
  10. Teixeira W, "Microleakage into and from two-stage implants : an in vitro comparative study", Int J Oral Maxillofac Implants, 26, pp.56~62 (2011)
  11. Mishra SK, "Microleakage at the different implant abutment interface: A systematic review", J Clin Diagn Res, 11, pp.ZE10~ZE15 (2017)
  12. Al-Jadaa A, "Comparison of three in vitro implant leakage testing methods", Clin Oral Implants Res, 26, pp.e1~e7 (2015)
  13. Harder S, "Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration", Clin Oral Investig, 14, pp.427~432 (2010)
  14. Nascimento C, "Marginal fit and microbial leakage along the implant-abutment interface of fixed partial prostheses : An in vitro analysis using Checkerboard DNA-DNA hybridization", J Prosthet Dent, 114, pp.831~838 (2015)
  15. Abdelhamed MI, "A Comparison of Zirconia and Titanium Abutments for Microleakage", Clin Implant Dent Relat Res, 17, pp.e643~e651 (2015)
  16. Nascimento CD, "Bacterial adhesion on the titanium and zirconia abutment surfaces", Clin Oral Implants Res, 25, pp.337~343 (2014)
  17. Smith NA, "Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values", J Prosthet Dent, 112, pp.561~567 (2014)
  18. Black DL, "Evaluation of the sealing capability of the internal conical connections of implants with titanium and zirconia abutments", J Contemp Dent Pract, 18, pp.915~922 (2017)
  19. Baixe S, "Microgap between zirconia abutments and titanium implants", Int J Oral Maxillofac Implants, 25, pp.455~460 (2010)
  20. Hamilton A, "Evaluation of the fit of CAD", CAM abutments, 2013, pp.26, 370~380

관련 논문AI추천

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and externalhex implant connectionsElaheh Beyabanaki, Hakimeh Siadat, Marzieh Alikhasi, Niloufar Mousavi대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems양동석, 윤미정, 정창모, 조재영, 허재찬, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제6호Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading이주희대한치과보철학회 · 대한치과보철학회지2017 · 제55권 제2호Correlation between microleakage and screw loosening at implantabutment connectionCem Sahin, Simel Ayyildiz대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제1호A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability권긍록, 문지회, 장은영, 홍성진대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Digital evaluation of axial displacement by implant-abutment connection type: an in vitro study김성준, 이규복, 손큰바다대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호

이 간행물의 다른 논문 (8건)