본문 바로가기
KERD
논문KCI 등재

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutmentfabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crownabutment interface were collected by washing with 500 μL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cementretained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Abstract

PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutmentfabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crownabutment interface were collected by washing with 500 μL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cementretained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

참고문헌 (33)

  1. Anadioti E, "3D and 2D marginal fit of pressed and CAD", CAM lithium disilicate crowns made from digital and conventional impressions, 2014, pp.23, 610~617
  2. Salvi GE, "Mechanical and technical risks in implant therapy", Int J Oral Maxillofac Implants, 24, pp.69~85 (2009)
  3. Shadid R, "A comparison between screw- and cement-retained implant prostheses. A literature review", J Oral Implantol, 38, pp.298~307 (2012)
  4. Linkevicius T, "The influence of margin location on the amount of undetected cement excess after delivery of cement-retained implant restorations", Clin Oral Implants Res, 22, pp.1379~1384 (2011)
  5. Linkevicius T, "Does residual cement around implant-supported restorations cause peri-implant disease? A retrospective case analysis", Clin Oral Implants Res, 24, pp.1179~1184 (2013)
  6. Linkevicius T, "The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study", Clin Oral Implants Res, 24, pp.71~76 (2013)
  7. 이현종, "Effects of cementless fixation of implant prosthesis: A finite element study", The Journal of Advanced of Prosthodontics, 11(6), pp.341~349 (2019), 대한치과보철학회[DOI]
  8. Assif D, "Accuracy of implant impression techniques", Int J Oral Maxillofac Implants, 11, pp.216~222 (1996)
  9. Jepsen S, "Primary prevention of peri-implantitis : managing peri-implant mucositis", J Clin Periodontol, 42, pp.S152~S157 (2015)
  10. Wittneben JG, "Clinical performance of screw-versus cement-retained fixed implant-supported reconstructions-a systematic review", Int J Oral Maxillofac Implants, 29, pp.84~98 (2014)
  11. Sailer I, "Schneider D Cemented and screw-retained implant reconstructions : a systematic review of the survival and complication rates", Clin Oral Implants Res, 23, pp.163~201 (2012)
  12. Lee JH, "A digital approach to fabricating an abutment replica to control cement volume in a cementretained implant prosthesis", J Prosthet Dent, 116, pp.25~28 (2016)
  13. Canullo L, "Clinical evaluation of an improved cementation technique for implant-supported restorations : a randomized controlled trial", Clin Oral Implants Res, 27, pp.1492~1499 (2016)
  14. Gómez-Polo M, "Factors affecting the decision to use cemented or screw-retained fixed implant-supported prostheses : A critical review", Int J Prosthodont, 31, pp.43~54 (2018)
  15. Lemos CA, "Evaluation of cement-retained versus screw-retained implant-supported restorations for marginal bone loss : a systematic review and meta-analysis", J Prosthet Dent, 115, pp.419~427 (2016)
  16. Carnaggio TV, "Retention of CAD", CAM all-ceramic crowns on prefabricated implant abutments : an in vitro comparative study of luting agents and abutment surface area, 2012, pp.21, 523~528
  17. Mehl C, "Retrievability of implant-retained crowns following cementation", Clin Oral Implants Res, 19, pp.1304~1311 (2008)
  18. Schierano G, "In vitro standardization of two different removal devices in cemented implant prosthesis", Clin Oral Implants Res, 27, pp.1026~1030 (2016)
  19. Nejatidanesh F, "Retentiveness of implant-supported metal copings using different luting agents", Dent Res J(Isfahan), 9, pp.13~18 (2012)
  20. Garg P, "Retentiveness of various luting agents used with implant-supported prostheses : a preliminary in vitro study", Int J Prosthodont, 26, pp.82~84 (2013)
  21. Busscher H, "Biofilm formation on dental restorative and implant materials", J Dent Res, 89, pp.657~665 (2010)
  22. Korsch M, "Effect of dental cements on peri-implant microbial community : comparison of the microbial communities inhabiting the peri-implant tissue when using different luting cements", Clin Oral Implants Res, 27, pp.e161~e166 (2016)
  23. Markowitz K, "Biologic properties of eugenol and zinc oxide-eugenol. A clinically oriented review", Oral Surg Oral Med Oral Pathol, 73, pp.729~737 (1992)
  24. Trowbridge HO, "Intradental sensory units : physiological and clinical aspects", J Endod, 11, pp.489~498 (1985)
  25. Taylor MJ, "Microleakage", J Dent, 20, pp.3~10 (1992)
  26. Boruziniat A, "Evaluation of the efficacy of flowable composite as lining material on microleakage of composite resin restorations : a systematic review and meta-analysis", Quintessence Int, 47, pp.93~101 (2016)
  27. Yavuz I, "New directıon for measurement of microleakage in cariology research", J Int Dent Med Res, 3, pp.19~24 (2010)
  28. Tjan AH, "Marginal leakage of cast gold crowns luted with an adhesive resin cement", J Prosthet Dent, 67, pp.11~15 (1992)
  29. 박진영, "Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis", The Journal of Advanced of Prosthodontics, 9(3), pp.159~169 (2017), 대한치과보철학회[DOI]
  30. Holst S, "A new triple-scan protocol for 3D fit assessment of dental restorations", Quintessence Int, 42, pp.651~657 (2011)
  31. Hepdeniz OK, "The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations", Eur J Dent, 10, pp.163~169 (2016)
  32. Takahashi N, "The effects of tetracycline, minocycline, doxycycline and ofloxacin on prevotella intermedia biofilm", Oral Microbiol Immunol, 21, pp.366~371 (2006)
  33. White SN, "Influence of marginal opening on microleakage of cemented artificial crowns", J Prosthet Dent, 71, pp.257~264 (1994)

이 간행물의 다른 논문 (9건)