Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey’s HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.
Abstract
PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey’s HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.
참고문헌 (41)
- Adell R., "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Adell R., "Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 5, pp.347~359 (1990)
- van Steenberghe D., "Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism : a prospective multicenter study on 558 fixtures", Int J Oral Maxillofac Implants, 5, pp.272~281 (1990)
- Lindquist LW., "A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss", Clin Oral Implants Res, 7, pp.329~336 (1996)
- Eckert SE., "Retrospective review of 1170 endosseous implants placed in partially edentulous jaws", J Prosthet Dent, 79, pp.415~421 (1998)
- Zarb GA., "The longitudinal clinical effectiveness of osseointegrated dental implants : the Toronto study. Part I : Surgical results", J Prosthet Dent, 63, pp.451~457 (1990)
- Zarb GA., "The longitudinal clinical effectiveness of osseointegrated dental implants : the Toronto study. Part III : Problems and complications encountered", J Prosthet Dent, 64, pp.185~194 (1990)
- Steinebrunner L., "Implantabutment interface design affects fatigue and fracture strength of implants", Clin Oral Implants Res, 19, pp.1276~1284 (2008)
- Rangert B., "Forces and moments on Branemark implants", Int J Oral Maxillofac Implants, 4, pp.241~247 (1989)
- Burguete RL., "Tightening characteristics for screwed joints in osseointegrated dental implants", J Prosthet Dent, 71, pp.592~599 (1994)
- Haack JE., "Elongation and preload stress in dental implant abutment screws", Int J Oral Maxillofac Implants, 10, pp.529~536 (1995)
- Rangert B., "Bending overload and implant fracture : a retrospective clinical analysis", Int J Oral Maxillofac Implants, 10, pp.326~334 (1995)
- Taylor TD., "Prosthodontic problems and limitations associated with osseointegration", J Prosthet Dent, 79, pp.74~78 (1998)
- Khraisat A., "Stability of the implant", abutment joint in a single-tooth external-hexagon implant system : clinical and mechanical review, 2004, pp.6, 222~229
- Kitagawa T., "Influence of implant", abutment joint designs on abutment screw loosening in a dental implant system, 2005, pp.75, 457~463
- Tsuge T., "Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants", Dent Mater J, 28, pp.373~381 (2009)
- Khayat PG., "An investigation of 131 consecutively placed wide screw-vent implants", Int J Oral Maxillofac Implants, 16, pp.827~832 (2001)
- Balfour A., "Comparative study of antirotational single tooth abutments", J Prosthet Dent, 73, pp.36~43 (1995)
- Smedberg JI., "On the influence of superstructure connection on implant preload : a methodological and clinical study", Clin Oral Implants Res, 7, pp.55~63 (1996)
- Rangert BR., "Load factor control for implants in the posterior partially edentulous segment", Int J Oral Maxillofac Implants, 12, pp.360~370 (1997)
- English CE., "Biomechanical concerns with fixed partial den tures involving implants", Implant Dent, 2, pp.221~242 (1993)
- Weinberg LA., "Reduction of implant loading with therapeutic biomechanics", Implant Dent, 7, pp.277~285 (1998)
- McGlumphy EA., "Implant screw mechanics", Dent Clin North Am, 42, pp.71~89 (1998)
- Martin WC., "Implant abutment screw rotations and preloads for four different screw materials and surfaces", J Prosthet Dent, 86, pp.24~32 (2001)
- Simon RL., "Single implant-supported molar and premolar crowns : a ten-year retrospective clinical report", J Prosthet Dent, 90, pp.517~521 (2003)
- Motosh N., "Development of design charts for bolts preloaded up to the plastic range", J Manuf Sci Eng, 98, pp.849~851 (1976)
- Jörnéus L., "Loads and designs of screw joints for single crowns supported by osseointegrated implants", Int J Oral Maxillofac Implants, 7, pp.353~359 (1992)
- Park JK., "Effects of abutment screw coating on implant preload", J Prosthodont, 19, pp.458~464 (2010)
- Merz BR., "Mechanics of the implant-abutment connection : an 8-degree taper compared to a butt joint connection", Int J Oral Maxillofac Implants, 15, pp.519~526 (2000)
- Norton MR., "An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design", Clin Oral Implants Res, 8, pp.290~298 (1997)
- Hansson S., "Implant-abutment interface : biomechanical study of flat top versus conical", Clin Implant Dent Relat Res, 2, pp.33~41 (2000)
- Theoharidou A., "Abutment screw loosening in single-implant restorations : a systematic review", Int J Oral Maxillofac Implants, 23, pp.681~690 (2008)
- Winkler S., "Implant screw mechanics and the settling effect : overview", J Oral Implantol, 29, pp.242~245 (2003)
- 이진선, "원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구", 대한치과보철학회지, 50(2), pp.92~98 (2012), 대한치과보철학회
- Bressan E., "Influence of abutment material on the gingival color of implant-supported all-ceramic restorations : a prospective multicenter study", Clin Oral Implants Res, 22, pp.631~637 (2011)
- Tamura Y., "Surface properties and biocompatibility of nitrided titanium for abrasion resistant implant materials", Dent Mater J, 21, pp.355~372 (2002)
- Mengel R., "The treatment of uncoated and titanium nitride-coated abutments with different instruments", Int J Oral Maxillofac Implants, 19, pp.232~238 (2004)
- Niinomi M., "Mechanical properties of biomedical titanium alloys", Mater Sci Eng A, 243, pp.231~236 (1998)
- Bickford J., "An Introduction to the design and behavior of bolted Joints" (1995), Marcel Dekker
- Corazza PH., "Carbon film coating of abutment surfaces : effect on the abutment screw removal torque", Implant Dent, 23, pp.434~438 (2014)
- Budinski KG., "Tribological properties of titanium alloys", Wear, 151, pp.203~217 (1991)
