용적세기조절회전방사선치료 (VMAT) 시 피부선량 감소를 위한 Jaw Tracking기법의 유용성 평가
Evaluation of Jaw Tracking Technique for Skin Dose Reduction during Volumetric Modulated Arc Therapy (VMAT)
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Since MLC used in VMAT is a stepped shield, leakage dose may occur between theleaves. In this study, we compared the skin doses of VMAT treatment plan with Jaw Trackingapplied to CT image obtained using phantom and VMAT treatment technology plan withoutJaw Tracking, and confirmed the usefulness of Jaw Tracking method. We intend to present adirection that can reduce patient exposure due to leakage dose of MLC. As a result, when the JawTracking method was used, the skin dose was reduced by 2.00 cGy on average, and the skin dosewas reduced by 3% compared to the Fixed Jaw method. As a result, when using the Jaw Trackingmethod with VMAT, the leakage and transmission radiation generated between the MLCleaves are reduced, and radiation treatment with a protective effect on the skin is possible whencompared with the case using Fixed Jaw.
Abstract
Since MLC used in VMAT is a stepped shield, leakage dose may occur between theleaves. In this study, we compared the skin doses of VMAT treatment plan with Jaw Trackingapplied to CT image obtained using phantom and VMAT treatment technology plan withoutJaw Tracking, and confirmed the usefulness of Jaw Tracking method. We intend to present adirection that can reduce patient exposure due to leakage dose of MLC. As a result, when the JawTracking method was used, the skin dose was reduced by 2.00 cGy on average, and the skin dosewas reduced by 3% compared to the Fixed Jaw method. As a result, when using the Jaw Trackingmethod with VMAT, the leakage and transmission radiation generated between the MLCleaves are reduced, and radiation treatment with a protective effect on the skin is possible whencompared with the case using Fixed Jaw.
참고문헌 (15)
- 안용찬, "세기조절 방사선치료 기술의 소개", 대한의사협회지, 54(11), pp.1172~1178 (2011), 대한의사협회
- 장경환, "동적 세기조절방사선치료에서 깊이에 따른 DLG변화 분석", 의학물리, 26(3), pp.153~159 (2015), 한국의학물리학회[DOI]
- Feng Z, "Dosimetric comparison between jaw tracking and static jaw techniques in intensity-modulated radiotherapy", Radiat. Oncol, 10(28), pp.1~7 (2015)
- Jabbari K, "Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators", Adv. Biomed. Res, 5, pp.193~ (2016)
- Jang HJ, "A Study of useful treatment which uses dualenergy when treating lung-cancer patient with stereotactic body radiation therapy using Volumetric-modulated arctherapy(VMAT)", Journal of the Korean society of radiation therapy, 1(1), pp.1~44 (2015)
- 정재용, "선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향", 의학물리, 23(1), pp.15~25 (2012), 한국의학물리학회[DOI]
- 김정남, "다엽콜리메이터의 임상적용을 위한 효율적인 정보 취득 기술", 한국콘텐츠학회 논문지, 8(11), pp.182~188 (2008), 한국콘텐츠학회
- Karthick Raj Mani, "Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study", Radiation oncology journal, 35(1), pp.90~100 (2017), 대한방사선종양학회
- Oh HT, "Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric ModulatedArc Therapy for Esophageal Cancer", Journal of the Korean Society of Radiation Therapy, 3(1), pp.33~41 (2019)
- Oh YK, "The Realization of Intensity-modulated Radiation Therapy Using the Liquid Shielding Material", Korean J. Med. Phys, 12(2), pp.155~160 (2001)
- Seungwoo Park, "A Study on Development and Usefulness of new Multi-Leaf Collimator for Diagnostic X-ray Equipment", Journal of Electrical Engineering & Technology, 13(2), pp.936~942 (2018), 대한전기학회
- Shim SH, "The Effect of Treatment for Radiation Skin Damage of Liver Stem Cells Originated from cord blood", Korean Association For Radiation Protection, 4, pp.74~75 (2011)
- 성지원, "RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때전달선량의 정확성 평가", 의학물리, 24(2), pp.127~132 (2013), 한국의학물리학회
- Dose Reduction Guidelines in Radiotherapy- related Imaging, "Wang JH", Radiation Safety Management, ~, pp.Radiation Safety Management Series. No. 5 (2014)
- Wu H, "A comparative study of identical VMAT plans with and without technique", Journal of Applied Clinical Medical Physics, 17(5), pp.133~141 (2016)
