본문 바로가기
KERD
논문KCI 등재

두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향

The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom’s body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

Abstract

In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom’s body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

참고문헌 (17)

  1. Chin D, "Head and neck cancer : Past, present and future", Expert Review of Anticancer Therapy, 6(7), pp.1111~1118 (2006)
  2. "Diagnosis and management of head and neck cancer: A national clinical guideline" (2006)[URL]
  3. Hurria A, "Predicting chemotherapy toxicity in older adults with cancer : A prospective multicenter study", Journal of Clinical Oncology, 29(25), pp.3457~3465 (2011)
  4. Ravasco P, "Impact of nutrition on outcome : A prospective randomized controller trial in patients with head and neck cancer undergoing radiotherapy", Journal of the Sciences and Specialties of the Head and Neck, 27(8), pp.659~668 (2005)
  5. Winqiust E, "Postoperative chemoradiotherpapy for advanced squamous cell carcinoma of the head and neck : A systemic review with meta-analysis", Journal of the Head and Specialties of the Head and Neck, 29(1), pp.38~46 (2007)
  6. Lees J, "Incidence of weight loss in head and neck cancer patients on commencing radiotherapy treatment at a regional oncology centre", Eur J Cancer Care(Engl), 8(3), pp.133~136 (1999)
  7. Vangelov B, "Critical weight loss in patients with oropharynx cancer during radiotherpay(± Chemotherapy)", Nutrition and Cancer, 69(8), pp.1211~1218 (2017)
  8. Seo SJ, "Evaluate the change of body shape and the patient alignement state during image-guided volumetric modulated arc therapy in head and neck cancer patients", KOSRT, 29(2), pp.109~117 (2017)
  9. Zhang L, "The impact of robustness of deformable image registration on contour propagation and dose accumulation for head and neck adaptive radiotherapy", J Appl Clin Med Phys, 19(4), pp.185~194 (2018)
  10. 오승종, "Deformable image registration in radiation therapy", Radiation oncology journal, 35(2), pp.101~111 (2017), 대한방사선종양학회
  11. Nie K, "Performance variations among clinically available deformable image registration tools in adaptive radiotherpay–How should we evaluate and interpret the result?", J Appl Cin Med Phys, 17(2), pp.328~340 (2016)
  12. 권경태, "전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가", 방사선기술과학, 40(3), pp.415~421 (2017), 대한방사선과학회[DOI]
  13. ICRU, "Prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50). International Commission on Radiation Units and Measurements (ICRU). Report 62", Journal of the ICRU, 7(2) (2007)
  14. Feuvret L, "Conformity index : A review", Int J Radiat Oncol Biol Phys, 64(2), pp.333~342 (2006)
  15. 강동진, "비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가", 방사선기술과학, 43(4), pp.265~272 (2020), 대한방사선과학회
  16. Garden AS, "Patterns of disease recurrence following treatment of oropharyngeal cancer with intensity modulated radiation therapy", International Journal of Radiation Oncology Biology Physics, 85(4), pp.941~947 (2013)
  17. Lee N, "Intensity-modulated radiation therapy with or without chemotherapy for nasopharyngeal carcinoma : Radiation therapy oncology group phase II trial 0225", H Clin Oncol, 27(22), pp.3684~3690 (2009)

관련 논문AI추천

비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가강동진, 민정환, 박소현, 신영주, 심재구, 정재용대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제4호용적변조회전 방사선치료 시 Set-up 오차에 따른선량 전달 정확성의 평가김상현, 나권우, 박성아, 이주훈, 하광은(사)한국방사선산업학회 · 방사선산업학회지2018 · 제12권 제1호두경부 종양의 적응방사선치료시 변형영상정합을 이용한 합성선량 평가강세식, 고성진, 김동현, 김정훈, 김창수, 예수영, 최석윤, 황철환대한방사선과학회 · Journal of Radiological Science and Technology2013 · 제36권 제3호두경부암에서 3차원 입체조형 방사선치료와 세기변조 방사선치료시 귀밑샘의 선량분포 비교김성규, 윤상모영남대학교 의과대학 · Journal of Yeungnam Medical Science2007 · 제24권 제2호소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가강동진, 권경태, 김연래, 민정환, 신영주, 정재용대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제1호AAPM TG-119 보고서를 통한 세기조절방사선치료(IMRT)와부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리박승, 강동진, 김연래, 김종하, 손승창, 신영주, 이근섭, 정재용대한방사선과학회 · Journal of Radiological Science and Technology2012 · 제35권 제3호

이 간행물의 다른 논문 (5건)