본문 바로가기
KERD
논문KCI 등재

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic toothmovement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Abstract

Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic toothmovement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

참고문헌 (24)

  1. Bergersen EO, "Enlargement and distortion in cephalometric radiography : compensation tables for linear measurements", Angle Orthod, 50, pp.230~244 (1980)
  2. Ashmore JL, "A 3-dimensional analysis of molar movement during headgear treatment", Am J Orthod Dentofacial Orthop, 121, pp.18~29 (2002)
  3. Miller RJ, "Validation of Align Technology’s Treat III digital model superimposition tool and its case application", Orthod Craniofac Res, 1(Suppl 1), pp.143~149 (2003)
  4. Hoggan BR, "The use of palatal rugae for the assessment of anteroposterior tooth movements", Am J Orthod Dentofacial Orthop, 119, pp.482~488 (2001)
  5. Choi DS, "Accuracy and reliability of palatal superimposition of three-dimensional digital models", Angle Orthod, 80, pp.497~503 (2010)
  6. Chen G, "Stable region for maxillary dental cast superimposition in adults, studied with the aid of stable miniscrews", Orthod Craniofac Res, 14, pp.70~79 (2011)
  7. An K, "Identification of a stable reference area for superimposing mandibular digital models", J Orofac Orthop, 76, pp.508~519 (2015)
  8. Cevidanes LH, "Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery", Am J Orthod Dentofacial Orthop, 131, pp.44~50 (2007)
  9. Noh H, "Registration accuracy in the integration of laser-scanned dental images into maxillofacial cone-beam computed tomography images", Am J Orthod Dentofacial Orthop, 140, pp.585~591 (2011)
  10. 박태준, "A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model", 대한치과교정학회지, 42(4), pp.169~181 (2012), 대한치과교정학회[DOI]
  11. Almukhtar A, "Comparison of the accuracy of voxel based registration and surface based registration for 3D assessment of surgical change following orthognathic surgery", PLoS One, 9, pp.e93402~ (2014)
  12. MacDonald-Jankowski DS, "Computed tomography for oral and maxillofacial surgeons. Part 2: cone-beam computed tomography", Asian J Oral Maxillofac Surg, 18, pp.85~92 (2006)
  13. Lee JH, "The 3D CT superimposition method using image fusion based on the maximum mutual information algorithm for the assessment of oral and maxillofacial surgery treatment results", Oral Surg Oral Med Oral Pathol Oral Radiol, 114, pp.167~174 (2012)
  14. Cevidanes LH, "Superimposition of 3D cone-beam CT models of orthognathic surgery patients", Dentomaxillofac Radiol, 34, pp.369~375 (2005)
  15. Choi JH, "A new method for superimposition of CBCT volumes", J Clin Orthod, 44, pp.303~312 (2010)
  16. Weissheimer A, "Fast three-dimensional superimposition of cone beam computed tomography for orthopaedics and orthognathic surgery evaluation", Int J Oral Maxillofac Surg, 44, pp.1188~1196 (2015)
  17. Bazina M, "Precision and reliability of Dolphin 3-dimensional voxel-based superimposition", Am J Orthod Dentofacial Orthop, 153, pp.599~606 (2018)
  18. Koerich L, "Rapid 3D mandibular superimposition for growing patients", Angle Orthod, 87, pp.473~479 (2017)
  19. Koerich L, "Threedimensional maxillary and mandibular regional superimposition using cone beam computed tomography : a validation study", Int J Oral Maxillofac Surg, 45, pp.662~669 (2016)
  20. Lin X, "Pointbased superimposition of a digital dental model on to a three-dimensional computed tomographic skull : an accuracy study in vitro", Br J Oral Maxillofac Surg, 53, pp.28~33 (2015)
  21. Ye N, "Integration accuracy of laser-scanned dental models into maxillofacial cone beam computed tomography images of different voxel sizes with different segmentation threshold settings", Oral Surg Oral Med Oral Pathol Oral Radiol, 117, pp.780~786 (2014)
  22. Nairn NJ, "Digital replacement of the distorted dentition acquired by cone beam computed tomography(CBCT) : a pilot study", Int J Oral Maxillofac Surg, 42, pp.1488~1493 (2013)
  23. Nada RM, "Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches", PLoS One, 6, pp.e16520~ (2011)
  24. Ruellas AC, "3D mandibular superimposition : comparison of regions of reference for voxelbased registration", PLoS One, 11, pp.e0157625~ (2016)

관련 논문AI추천

A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model박태준, 이기수, 이상현대한치과교정학회 · 대한치과교정학회지2012 · 제42권 제4호Validation of three-dimensional digital model superimpositions based on palatal structures in patients with maximum anterior tooth retraction following premolar extraction차정열, 최성환, Ji-Hoi Kim, Jing Liu, Kyong-Min Koh대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제4호콘빔시티 촬영 프로토콜에 따른 DICOM 파일의 STL 변환 디지털 모델의 정확도 비교김영현, 나지연, 우창우, 이정희, 정호걸, 차정열, 한상선, 황재준대한통합치과학회 · 대한통합치과학회지2017 · 제6권 제1호Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone lossHangmiao Lyu, Huimin Ma, Jianxia Hou, Li Xu, Weiran Li, Xiaotong Li, Xiaoxia Wang, Yijiao Zhao, Yong Wang대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제2호An effective approach to assessing inter-root distances using tooth models without repeated cone-beam computed tomography scans during orthodontic treatmentHaeun Moon, Jaewon Koh, Kyungmin Clara Lee, Min Kyeong Lee, Phimon Atsawasuwan, Veerasathpurush Allareddy대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study윤달선, 장인산, 차봉근, 최동순대한치과교정학회 · 대한치과교정학회지2018 · 제48권 제4호

이 간행물의 다른 논문 (8건)