본문 바로가기
KERD
논문KCI 등재

Evaluation of the effects of the third molar on distalization and the effects of attachments on distalization and expansion with clear aligners: Three-dimensional finite element study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: This study aimed to evaluate the effects of attachment design on maxillary molar distalization and simultaneous expansion during distalization, and the influence of third molars on distalization in the clear aligner technique using the finite element method. Methods: Six models were created to evaluate three different attachment designs on the second molars. Model I: employed a vertical rectangular attachment; Model II: used a vertical rectangular attachment with the presence of the third molar; Model III: used a combined semi-elliptical attachment; and Model IV: featured an opposed semi-elliptical attachment with buccal and palatal components. Models I through IV focused on distalization. Models V and VI were created by adding expansions to Models III and IV. The displacement amounts, clear aligner deformations, and stress distributions were analyzed using Ansys 19.2. Results: The presence of a third molar reduced maximum total displacement by 17%. Models I and III demonstrated similar distal displacement and tipping, both of which were more pronounced than in Model IV. Model IV achieved the most parallel tooth movement, with the least distal and buccal tipping and minimal distopalatal rotation. In the comparison of Models V and VI, Model VI exhibited greater distal and buccal displacements and more tipping than Model V. Conclusions: The presence of a third molar reduced distalization efficiency and increased clear aligner deformation. For both movements, the attachment that provided the most parallel movement showed the least displacement. When selecting attachments, it is essential to consider factors such as tooth rotation, inclination, bone support, and root health.

Abstract

Objective: This study aimed to evaluate the effects of attachment design on maxillary molar distalization and simultaneous expansion during distalization, and the influence of third molars on distalization in the clear aligner technique using the finite element method. Methods: Six models were created to evaluate three different attachment designs on the second molars. Model I: employed a vertical rectangular attachment; Model II: used a vertical rectangular attachment with the presence of the third molar; Model III: used a combined semi-elliptical attachment; and Model IV: featured an opposed semi-elliptical attachment with buccal and palatal components. Models I through IV focused on distalization. Models V and VI were created by adding expansions to Models III and IV. The displacement amounts, clear aligner deformations, and stress distributions were analyzed using Ansys 19.2. Results: The presence of a third molar reduced maximum total displacement by 17%. Models I and III demonstrated similar distal displacement and tipping, both of which were more pronounced than in Model IV. Model IV achieved the most parallel tooth movement, with the least distal and buccal tipping and minimal distopalatal rotation. In the comparison of Models V and VI, Model VI exhibited greater distal and buccal displacements and more tipping than Model V. Conclusions: The presence of a third molar reduced distalization efficiency and increased clear aligner deformation. For both movements, the attachment that provided the most parallel movement showed the least displacement. When selecting attachments, it is essential to consider factors such as tooth rotation, inclination, bone support, and root health.

관련 논문AI추천

Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study김용일, Choi Youn-Kyung, Kim Ki Beom, Kim Sung-Hun, Ko Ching-Chang, Oh Sewoong대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제6호En masse maxillary dentition distalization with clear aligners using infrazygomatic mini-implants: A finite element studyAllahyar Geramy, Joseph Bouserhal, Lina Medawar, Nayla Bassil Nassif, Nicolas Nassar, Patrick Sayegh, Roland Kmeid대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Evaluation of the effect of attachments on torque control of palatally positioned maxillary lateral teeth with clear aligners: Finite element analysisIrmak Ocak, Nurver Karsli, Ömür Polat Özsoy, Sevil Gökcek대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제1호Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation methodJong-Chan Baik, Ki Beom Kim, Seong-Sik Kim, Soo-Byung Park, Sung-Hun Kim, Yonghun Cho, Yong-Il Kim, Youn-Kyung Choi, Yunju Baek대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제6호Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extractionKi Beom Kim, Kiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호In vitro analysis of mandibular arch response to canine distalization with aligners at varying initial angulationsAn Le, Fan Yongjie, Guo Baoxiong, Liu Gebing, Lv Xin, Wang Bingle, Yang Sensen대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제4호

이 간행물의 다른 논문 (7건)