Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (−1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and −1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.[Korean J Orthod 2016;46(4):242-252]

Abstract

Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (−1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and −1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.[Korean J Orthod 2016;46(4):242-252]

참고문헌 (28)

  1. Cha BK, "Analysis of tooth movement in extraction cases using three-dimensional reverse engineering technology", Eur J Orthod, 29, pp.325~331 (2007)
  2. Cho MY, "Three-dimensional analysis of the tooth movement and arch dimension changes in Class I malocclusions treated with first premolar extractions: a guideline for virtual treatment planning", Am J Orthod Dentofacial Orthop, 138, pp.747~757 (2010)
  3. Lai EH, "Three dimensional dental model analysis of treatment outcomes for protrusive maxillary dentition:comparison of headgear, miniscrew, and miniplate skeletal anchorage", Am J Orthod Dentofacial Orthop, 134, pp.636~645 (2008)
  4. Upadhyay M, "Treatment effects of mini-implants for en-masse retraction of anterior teeth in bialveolar dental protrusion patients: a randomized controlled trial", Am J Orthod Dentofacial Orthop, 134, pp.18~29.e1 (2008)
  5. Upadhyay M, "Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study", Am J Orthod Dentofacial Orthop, 134, pp.803~810 (2008)
  6. Lim JK, "Gummy smile correction using mini implant", Korean J Clin Orthod, 9, pp.14~31 (2010)
  7. Lee KJ, "Displacement pattern of the maxillary arch depending on miniscrew position in sliding mechanics", Am J Orthod Dentofacial Orthop, 140, pp.224~232 (2011)
  8. 김수진, "간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가", 대한치과교정학회지, 38(6), pp.376~387 (2008), 대한치과교정학회
  9. 이한아, "Miniscrew implant를 이용한 상악 구치부 압하와 개방교합 치료의 효과 및 안정성", 대한치과교정학회지, 38(1), pp.31~40 (2008), 대한치과교정학회
  10. Mo SS, "Factors controlling anterior torque with C-implants depend on en-masse retraction without posterior appliances: biocreative therapy type II technique", Am J Orthod Dentofacial Orthop, 139, pp.e183~e191 (2011)
  11. Tominaga JY, "Optimal loading conditions for controlled movement of anterior teeth in sliding mechanics", Angle Orthod, 79, pp.1102~1107 (2009)
  12. Sia S, "Experimental determination of optimal force system required for control of anterior tooth movement in sliding mechanics", Am J Orthod Dentofacial Orthop, 135, pp.36~41 (2009)
  13. Kojima Y, "A finite element simulation of initial movement, orthodontic movement, and the centre of resistance of the maxillary teeth connected with an archwire", Eur J Orthod, 36, pp.255~261 (2014)
  14. 정득룡, "3차원 영상을 이용한 상악 소구치 발치공간 폐쇄 후 상악 구치부 회전양상의 평가", 대한치과교정학회지, 35(6), pp.451~458 (2005), 대한치과교정학회
  15. 정광모, "상악 치아군의 저항중심의 위치에 관한 3차원 유한요소 해석", 대한치과교정학회지, 39(2), pp.83~94 (2009), 대한치과교정학회
  16. Germane N, "Three biologic variables modifying faciolingual tooth angulation by straight-wire appliances", Am J Orthod Dentofacial Orthop, 96, pp.312~319 (1989)
  17. Andrews LF, "The straight-wire appliance. Explained and compared", J Clin Orthod, 10, pp.174~195 (1976)
  18. Coolidge ED, "The thickness of the human periodontal membrane", J Am Dent Assoc Dent Cosm, 24, pp.1260~1270 (1937)
  19. Tanne K, "Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces", Am J Orthod Dentofacial Orthop, 92, pp.499~505 (1987)
  20. Eui-Hyang Sung, "Distalization pattern of whole maxillary dentition according to force application points", 대한치과교정학회지, 45(1), pp.20~28 (2015), 대한치과교정학회
  21. Marcuschamer E, "Anatomical crown width", length ratios of worn and unworn maxillary teeth in Asian subjects, 2011, pp.31, 495~503
  22. Brook AH, "The relationship of crown length to root length in permanent maxillary central incisors", Proc Br Paedod Soc, 8, pp.17~20 (1978)
  23. Sia S, "Determining the center of resistance of maxillary anterior teeth subjected to retraction forces in sliding mechanics. An in vivo study", Angle Orthod, 77, pp.999~1003 (2007)
  24. Sung SJ, "Effective en-masse retraction design with orthodontic miniimplant anchorage: a finite element analysis", Am J Orthod Dentofacial Orthop, 137, pp.648~657 (2010)
  25. van Steenbergen E, "The relation between the point of force application and flaring of the anterior segment", Angle Orthod, 75, pp.730~735 (2005)
  26. Choy K, "Initial changes of centres of rotation of the anterior segment in response to horizontal forces", Eur J Orthod, 28, pp.471~474 (2006)
  27. Park HS, "Group distal movement of teeth using microscrew implant anchorage", Angle Orthod, 75, pp.602~609 (2005)
  28. 박헌묵, "Preliminary three-dimensional analysis of tooth movement and arch dimension change of the maxillary dentition in Class II division 1 malocclusion treated with first premolar extraction: conventional anchorage vs. mini-implant anchorage", 대한치과교정학회지, 42(6), pp.280~290 (2012), 대한치과교정학회

관련 논문AI추천

Distalization pattern of whole maxillary dentition according to force application points김성진, 박영철, 유형석, 이기준, 전윤식, Eui-Hyang Sung대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제1호The effects of alveolar bone loss and miniscrew position on initial tooth displacement during intrusion of the maxillary anterior teeth: Finite element analysis유형석, 최성환, 황충주, Sang-Jin Sung, Sun-Mi Cho대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제5호Finite element analysis of the effects of different archwire forms and power arm positions on maxillary incisors in en masse retraction using fixed lingual orthodontic appliancesHilal Tarkan, Ihsan Sami Guvenc대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제5호Effect of archwire stiffness and friction on maxillary posterior segment displacement during anterior segment retraction: A three-dimensional finite element analysisChoon-Soo Park, Hyung-Seog Yu, Jung-Yul Cha, Kee-Joon Lee, Sung-Seo Mo대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제6호Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element studyJae Hyun Park, Jong-Moon Chae, Sunock Yun, Yoon-Ah Kook, Yukio Kojima대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제3호Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study나영현, 박명순, 박민봉, 안장훈대한치과교정학회 · 대한치과교정학회지2017 · 제47권 제5호

이 간행물의 다른 논문 (7건)