본문 바로가기
KERD
논문KCI 등재

Surface Characteristics and Biocompatibility of Titanium Coated with Dentin-derived Hydroxyapatite

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

The aim of this study was to evaluate surface characteristics and biological properties of the dentin -derived hydroxyapatite (HA) coating on titanium substrate. Dentinderived HA was obtained from extracted human teeth using a calcination method at 850oC. The commercially pure titanium (cp-Ti, ASTM Grade II) was used as a metallic substrate and a radio frequency magnetron sputtering method was employed as a coating method. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) were utilized to investigate the coating aspects and composition. Atomic forced microscopy (AFM)and a surface profiler were used to assess the surface morphology and roughness. Corrosion tests were performed in phosphate- buffered saline at a 36.5 ± 1oC in order to determine the corrosion behavior of the uncoated and coated specimens. The biocompatibility of dentin-derived HA coated specimens with fetal rat calvarial cells and human gingival fibroblasts was assessed by SEM and cell proliferation analysis. The results showed that the dentin-derived HA coatings appeared to cover thinly and homogeneously the surfaces without changing of the titanium substrate. The EDX analysis of this the coating surface indicated the presence of Ca and P elements. The mean surface roughness of cp-Ti and dentin-derived coating specimens was 0.27 μm and, 1.7 μm, respectively. Corrosion tests indicated a stable passive film of the dentin-derived HA coating specimens. SEM observations of fetal rat calvarial cells and human fibroblast cells on coated surfaces showed that the cells proliferated and developed a network of dense interconnections. The cells on all specimens proliferated actively within the culture period, showing good cell viability. At day 1 and 3, dentin-derived coating specimens showed 89% and 93%cell viability, respectively, when normalized to cp-Ti specimens. These results suggest that dentin-derived HA coating using the RF magnetron sputtering method has good surface characteristics and biocompatibility.

Abstract

The aim of this study was to evaluate surface characteristics and biological properties of the dentin -derived hydroxyapatite (HA) coating on titanium substrate. Dentinderived HA was obtained from extracted human teeth using a calcination method at 850oC. The commercially pure titanium (cp-Ti, ASTM Grade II) was used as a metallic substrate and a radio frequency magnetron sputtering method was employed as a coating method. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) were utilized to investigate the coating aspects and composition. Atomic forced microscopy (AFM)and a surface profiler were used to assess the surface morphology and roughness. Corrosion tests were performed in phosphate- buffered saline at a 36.5 ± 1oC in order to determine the corrosion behavior of the uncoated and coated specimens. The biocompatibility of dentin-derived HA coated specimens with fetal rat calvarial cells and human gingival fibroblasts was assessed by SEM and cell proliferation analysis. The results showed that the dentin-derived HA coatings appeared to cover thinly and homogeneously the surfaces without changing of the titanium substrate. The EDX analysis of this the coating surface indicated the presence of Ca and P elements. The mean surface roughness of cp-Ti and dentin-derived coating specimens was 0.27 μm and, 1.7 μm, respectively. Corrosion tests indicated a stable passive film of the dentin-derived HA coating specimens. SEM observations of fetal rat calvarial cells and human fibroblast cells on coated surfaces showed that the cells proliferated and developed a network of dense interconnections. The cells on all specimens proliferated actively within the culture period, showing good cell viability. At day 1 and 3, dentin-derived coating specimens showed 89% and 93%cell viability, respectively, when normalized to cp-Ti specimens. These results suggest that dentin-derived HA coating using the RF magnetron sputtering method has good surface characteristics and biocompatibility.

참고문헌 (34)

  1. Gottlander M, "Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone", Int J Oral Maxillofac Implants, 6, pp.399~404 (1991)
  2. Wennerberg A, "Design and surface characteristics of 13 commercially available oral implant systems", Int J Oral Maxillofac Implants, 8, pp.622~633 (1993)
  3. Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
  4. Glauser R, "Initial implant stability using different implant designs and surgical techniques", Applied Osseointegration Research, 2, pp.6~8 (2001)
  5. Hutton JE, "Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Branemark implants", Int J Oral Maxillofac Implants, 10, pp.33~42 (1995)
  6. Klokkevold PR, "Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit", Clin Oral Implants Res, 8, pp.442~447 (1997)
  7. Deporter DA, "A histological assessment of the initial healing response adjacent to porous-surfaced, titanium alloy dental implants in dogs", J Dent Res, 65, pp.1064~1070 (1986)
  8. Pilliar RM, "The effect of partial coating with hydroxyapatite on bone remodeling in relation to porous-coated titanium-alloy dental implants in the dog", J Dent Res, 70, pp.1338~1345 (1991)
  9. Kurkcu M, "Histomorphometric evaluation of implants coated with enamel or dentine derived fluoride-substituted apatite", J Mater Sci Mater Med, 19, pp.59~65 (2008)
  10. Goller G, "Plasma-sprayed human bone-derived hydroxyapatite coatings: effective and reliable", J Materials Letters, 58, pp.2599~2604 (2004)
  11. Forsgren J, "Formation and adhesion of biomimetic hydroxyapatite deposited on titanium substrates", Acta Biomater, 3, pp.980~984 (2007)
  12. Nelea V, "Microstructure and mechanical properties of hydroxyapatite thin films grown by RF magnetron sputtering", Surface and Coatings Technology, 173, pp.315~322 (2003)
  13. Ong JL, "Bone response to plasmasprayed hydroxyapatite and radiofrequency-sputtered calcium phosphate implants in vivo", Int J Oral Maxillofac Implants, 17, pp.581~586 (2002)
  14. Park YS, "The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae", Int J Oral Maxillofac Implants, 20, pp.31~38 (2005)
  15. Valerio P, "Biocompatibility evaluation of dentin, enamel, bone derived hydroxyapatite", Key Engineering Materials, 254, pp.837~840 (2004)
  16. Oktar FN, "A histological study of human derived tooth hydroxyapatite", Key Engineering Materials, 309, pp.27~30 (2006)
  17. Kim YG, "Biomechanical study of the calvarial defects after implantation of the toothash and plaster in the rat", Korean Asso Maxillofac Plast Reconstr Surg, 19, pp.45~54 (1997)
  18. Oktar FN, "Histopathological evaluation of tooth derived grafting material in rabbits", Proceeding of the National Biomedical Engineering Symposium of Biyomut, 97, pp.54~61 (1997)
  19. de Groot K, "Plasma sprayed coatings of hydroxylapatite", J Biomed Mater Res, 21, pp.1375~1381 (1987)
  20. Radin SR, "Plasma spraying induced changes of calcium phosphate ceramic characteristics and the effect on in vitro stability", J Mater Sci: Mater Med, 3, pp.33~42 (1992)
  21. Singh RK, "Excimer laser deposition of hydroxyapatite thin films", Biomaterials, 15, pp.522~528 (1994)
  22. Yoshinari M, "The biocompatibility(cell culture and histologic study) of hydroxy-apatitecoatedimplants created by ion beam dynamic mixing", Clin Oral Implants Res, 7, pp.96~100 (1996)
  23. Jung YC, "Effects of ion beamassisted deposition of hydroxyapatite on the osseointegration of endosseous implants in rabbit tibiae", Int J Oral Maxillofac Implants, 16, pp.809~818 (2001)
  24. Wong M, "Effect of surface topology on the osseointegration of implant materials in trabecular bone", J Biomed Mater Res, 29, pp.1567~1575 (1995)
  25. Bachle M, "A systematic review of the influence of different titanium surfaces on proliferation, differentiation and protein synthesis of osteoblast-like MG63 cells", Clin Oral Implants Res, 15, pp.683~692 (2004)
  26. Larsson C, "Bone response to surface modified titanium implants - studies on the tissue response after 1 year to machined and electropolished implants with different oxide thicknesses", J Mater Sci Mater Med, 8, pp.721~729 (1997)
  27. Wennerberg A, "On surface roughness and Implant incorporation", Department of Biomaterials, pp.1997
  28. Karrholm J, "Fixation and metal release from the Tifit femoral stem prosthesis. 5-year follow-up of 64 cases", Acta Orthop Scand, 69, pp.369~378 (1998)
  29. Okazaki Y, "Comparison of metal release from various metallic biomaterials in vitro", Biomaterials, 26, pp.11~21 (2005)
  30. Fathi MH, "Novel hydroxyapatite", tantalum surface coating for metallic dental implant, 2007, pp.61, 1238~1241
  31. Layman DL, "Growth inhibitory effects of endotoxins from Bacteroides gingivalis and intermedius on human gingival fibroblasts in vitro", J Periodontol, 58, pp.387~392 (1987)
  32. Whitson SW, "Factors influencing synthesis and mineralization of bone matrix from fetal bovine bone cells grown in vitro", J Bone Miner Res, 7, pp.727~741 (1992)
  33. Saito T, "Behavior of MC3T3-E1 osteoblast-like cells cultured on a glass substrate with different surface rougness", Key Engineering Materials, 284, pp.573~576 (2005)
  34. Le Guehennec L, "Osteoblastic cell behaviour on different titanium implant surfaces", Acta Biomater, 4, pp.535~543 (2008)

관련 논문AI추천

이 간행물의 다른 논문 (5건)