Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse MC3T3-E1 cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide (TiO2) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized TiO2 surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.

Abstract

Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse MC3T3-E1 cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide (TiO2) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized TiO2 surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.

참고문헌 (33)

  1. Uzumaki ET, "Titanium oxide(TiO2)coatings produced on titanium by oxygen plasma immersion and cell behavior on TiO2", Key Eng Mater, 18, pp.367~370 (2006)
  2. Kasemo B, "Biocompatibility of titanium implants : surface science aspects", J Prosthet Dent, 49, pp.832~837 (1983)
  3. Baier RE, "Implant surface characteristics and tissue interaction", J Oral Implantol, 13, pp.594~606 (1988)
  4. Ong JL, "Effect of surface topography of titanium on surface chemistry and cellular response", Implant Dent, 5, pp.83~88 (1996)
  5. Placko HE, "Surface characterization of titanium-based implant materials", Int J Oral Maxillofac Implants, 15, pp.355~363 (2000)
  6. Larsson C, "Bone response to surface modified titanium implants : studies on electropolished implants with different oxide thicknesses and morphology", Biomaterials, 15, pp.1062~1074 (1994)
  7. Larsson C, "Bone response to surface-modified titanium implants : studies on the early tissue response to machined and electropolished implants with different oxide thicknesses", Biomaterials, 17, pp.605~616 (1996)
  8. Lausmaa J., "Mechanical, thermal, chemical and electrochemical surface treatment of titanium, In Titanium in medicine", pp.231~266 (2011), Springer
  9. Sittig C, "Surface characterization of implant materials c.p. Ti, Ti- 6Al-7Nb and Ti-6Al-4V with different pretreatments", J Mater Sci Mater Med, 10, pp.35~46 (1999)
  10. Bordji K, "Cytocompatibility of Ti-6Al-4V and Ti-5Al-2.5Fe alloys according to three surface treatments, using human fibroblasts and osteoblasts", Biomaterials, 17, pp.929~940 (1996)
  11. Yao C, "Anodization : a promising nano-modification technique of titanium implants for orthopedic applications", J Nanosci Nanotechnol, 6, pp.2682~2692 (2006)
  12. Sato M, "Nanobiotechnology : implications for the future of nanotechnology in orthopedic applications", Expert Rev Med Devices, 1, pp.105~114 (2004)
  13. Sul YT, "Oxidized implants and their influence on the bone response", J Mater Sci Mater Med, 12, pp.1025~1031 (2001)
  14. Sul YT, "Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone : effect of calcium surface chemistry of a novel implant", Clin Implant Dent Relat Res, 6, pp.101~110 (2004)
  15. Sul YT, "Optimum surface properties of oxidized implants for reinforcement of osseointegration: surface chemistry, oxide thickness, porosity, roughness, and crystal structure", Int J Oral Maxillofac Implants, 20, pp.349~359 (2005)
  16. Sul YT, "The bone response of oxidized bioactive and non-bioactive titanium implants", Biomaterials, 26, pp.6720~6730 (2005)
  17. Sunny MC, "Titanium-protein interaction : changes with oxide layer thickness", J Biomater Appl, 6, pp.89~98 (1991)
  18. Sundgren JE, "Auger electron spectroscopic studies of the interface between human tissue and implants of titanium and stainless steel", J Colloid Interface Sci, 110, pp.9~20 (1986)
  19. Schreckenbach JP, "Characterization of anodic spark-converted titanium surfaces for biomedical applications", J Mater Sci Mater Med, 10, pp.453~457 (1999)
  20. Jeong YH, "Corrosion characteristics of anodized Ti-(10-40wt%)Hf alloys for metallic biomaterials use", J Mater Sci Mater Med, 22, pp.41~50 (2011)
  21. Song Hj, "The effects of spark anodizing treatment of pure titanium metals and titanium alloys on corrosion characteristics", Surf Coat Technol, 201, pp.8738~8745 (2007)
  22. Yao C, "Enhanced osteoblast functions on anodized titanium with nanotube-like structures", J Biomed Mater Res A, 85, pp.157~166 (2008)
  23. Sul YT, "The significance of the surface properties of oxidized titanium to the bone response : special emphasis on potential biochemical bonding of oxidized titanium implant", Biomaterials, 24, pp.3893~3907 (2000)
  24. Sul YT, "Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides", Clin Oral Implants Res, 13, pp.252~259 (2002)
  25. Bae IH, "Anodic oxidized nanotubular titanium implants enhance bone morphogenetic protein-2 delivery", J Biomed Mater Res B Appl Biomater, 93, pp.484~491 (2010)
  26. Balasundaram G, "TiO2 nanotubes functionalized with regions of bone morphogenetic protein-2 increases osteoblast adhesion", J Biomed Mater Res A, 84, pp.447~453 (2008)
  27. Das K, "Surface modifications and cell-materials interactions with anodized Ti", Acta Biomater, 3, pp.573~585 (2007)
  28. Webb K, "Relative importance of surface wettability and charged functional groups on NIH 3T3 fibroblast attachment, spreading, and cytoskeletal organization", J Biomed Mater Res, 41, pp.422~430 (1988)
  29. Eriksson C, "Implantation of hydrophilic and hydrophobic titanium discs in rat tibia : cellular reactions on the surfaces during the first 3 weeks in bone", Biomaterials, 25, pp.4759~4766 (2004)
  30. Eriksson C, "Polymorphonuclear leukocytes in coagulating whole blood recognize hydrophilic and hydrophobic titanium surfaces by different adhesion receptors and show different patterns of receptor expression", J Lab Clin Med, 137, pp.296~302 (2001)
  31. Oh HJ, "Microstructural characterization of biomedical titanium oxide film fabricated by electrochemical method", Surf Coat Technol, 198, pp.247~252 (2005)
  32. Zhao G, "High surface energy enhances cell response to titanium substrate microstructure", J Biomed Mater Res A, 74, pp.49~58 (2005)
  33. 이보아, "Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium- 8tantalum-3niobium alloy", Journal of Periodontal & Implant Science, 42(6), pp.248~255 (2012), 대한치주과학회

관련 논문AI추천

이 간행물의 다른 논문 (7건)