Surface characteristics and bioactivity of an anodized titanium surface
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse MC3T3-E1 cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide (TiO2) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized TiO2 surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.
Abstract
Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse MC3T3-E1 cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide (TiO2) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized TiO2 surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.
참고문헌 (33)
- Uzumaki ET, "Titanium oxide(TiO2)coatings produced on titanium by oxygen plasma immersion and cell behavior on TiO2", Key Eng Mater, 18, pp.367~370 (2006)
- Kasemo B, "Biocompatibility of titanium implants : surface science aspects", J Prosthet Dent, 49, pp.832~837 (1983)
- Baier RE, "Implant surface characteristics and tissue interaction", J Oral Implantol, 13, pp.594~606 (1988)
- Ong JL, "Effect of surface topography of titanium on surface chemistry and cellular response", Implant Dent, 5, pp.83~88 (1996)
- Placko HE, "Surface characterization of titanium-based implant materials", Int J Oral Maxillofac Implants, 15, pp.355~363 (2000)
- Larsson C, "Bone response to surface modified titanium implants : studies on electropolished implants with different oxide thicknesses and morphology", Biomaterials, 15, pp.1062~1074 (1994)
- Larsson C, "Bone response to surface-modified titanium implants : studies on the early tissue response to machined and electropolished implants with different oxide thicknesses", Biomaterials, 17, pp.605~616 (1996)
- Lausmaa J., "Mechanical, thermal, chemical and electrochemical surface treatment of titanium, In Titanium in medicine", pp.231~266 (2011), Springer
- Sittig C, "Surface characterization of implant materials c.p. Ti, Ti- 6Al-7Nb and Ti-6Al-4V with different pretreatments", J Mater Sci Mater Med, 10, pp.35~46 (1999)
- Bordji K, "Cytocompatibility of Ti-6Al-4V and Ti-5Al-2.5Fe alloys according to three surface treatments, using human fibroblasts and osteoblasts", Biomaterials, 17, pp.929~940 (1996)
- Yao C, "Anodization : a promising nano-modification technique of titanium implants for orthopedic applications", J Nanosci Nanotechnol, 6, pp.2682~2692 (2006)
- Sato M, "Nanobiotechnology : implications for the future of nanotechnology in orthopedic applications", Expert Rev Med Devices, 1, pp.105~114 (2004)
- Sul YT, "Oxidized implants and their influence on the bone response", J Mater Sci Mater Med, 12, pp.1025~1031 (2001)
- Sul YT, "Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone : effect of calcium surface chemistry of a novel implant", Clin Implant Dent Relat Res, 6, pp.101~110 (2004)
- Sul YT, "Optimum surface properties of oxidized implants for reinforcement of osseointegration: surface chemistry, oxide thickness, porosity, roughness, and crystal structure", Int J Oral Maxillofac Implants, 20, pp.349~359 (2005)
- Sul YT, "The bone response of oxidized bioactive and non-bioactive titanium implants", Biomaterials, 26, pp.6720~6730 (2005)
- Sunny MC, "Titanium-protein interaction : changes with oxide layer thickness", J Biomater Appl, 6, pp.89~98 (1991)
- Sundgren JE, "Auger electron spectroscopic studies of the interface between human tissue and implants of titanium and stainless steel", J Colloid Interface Sci, 110, pp.9~20 (1986)
- Schreckenbach JP, "Characterization of anodic spark-converted titanium surfaces for biomedical applications", J Mater Sci Mater Med, 10, pp.453~457 (1999)
- Jeong YH, "Corrosion characteristics of anodized Ti-(10-40wt%)Hf alloys for metallic biomaterials use", J Mater Sci Mater Med, 22, pp.41~50 (2011)
- Song Hj, "The effects of spark anodizing treatment of pure titanium metals and titanium alloys on corrosion characteristics", Surf Coat Technol, 201, pp.8738~8745 (2007)
- Yao C, "Enhanced osteoblast functions on anodized titanium with nanotube-like structures", J Biomed Mater Res A, 85, pp.157~166 (2008)
- Sul YT, "The significance of the surface properties of oxidized titanium to the bone response : special emphasis on potential biochemical bonding of oxidized titanium implant", Biomaterials, 24, pp.3893~3907 (2000)
- Sul YT, "Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides", Clin Oral Implants Res, 13, pp.252~259 (2002)
- Bae IH, "Anodic oxidized nanotubular titanium implants enhance bone morphogenetic protein-2 delivery", J Biomed Mater Res B Appl Biomater, 93, pp.484~491 (2010)
- Balasundaram G, "TiO2 nanotubes functionalized with regions of bone morphogenetic protein-2 increases osteoblast adhesion", J Biomed Mater Res A, 84, pp.447~453 (2008)
- Das K, "Surface modifications and cell-materials interactions with anodized Ti", Acta Biomater, 3, pp.573~585 (2007)
- Webb K, "Relative importance of surface wettability and charged functional groups on NIH 3T3 fibroblast attachment, spreading, and cytoskeletal organization", J Biomed Mater Res, 41, pp.422~430 (1988)
- Eriksson C, "Implantation of hydrophilic and hydrophobic titanium discs in rat tibia : cellular reactions on the surfaces during the first 3 weeks in bone", Biomaterials, 25, pp.4759~4766 (2004)
- Eriksson C, "Polymorphonuclear leukocytes in coagulating whole blood recognize hydrophilic and hydrophobic titanium surfaces by different adhesion receptors and show different patterns of receptor expression", J Lab Clin Med, 137, pp.296~302 (2001)
- Oh HJ, "Microstructural characterization of biomedical titanium oxide film fabricated by electrochemical method", Surf Coat Technol, 198, pp.247~252 (2005)
- Zhao G, "High surface energy enhances cell response to titanium substrate microstructure", J Biomed Mater Res A, 74, pp.49~58 (2005)
- 이보아, "Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium- 8tantalum-3niobium alloy", Journal of Periodontal & Implant Science, 42(6), pp.248~255 (2012), 대한치주과학회