Objectives: This study developed and validated an analysis method of urinary metals and metalloids that can be applied inductively with coupled plasma mass spectrometry (ICP-MS). Methods: 0.3 mL of urine was used to analyze 25 metal and metalloid compounds using ICP-MS. The validation of the analytical method included linearity, accuracy, precision, and the calculation of detection limits. In addition, a comparison test was performed with the graphite furnace atomic absorption spectrometry (GF-AAS) method, which is the current standard method, with urine samples of 66 healthy subjects. Results: The linearities (R2 ) of calibration curves of all 25 compounds were ≥ 0.999. Of the 25 compounds, the intra-day and inter-day accuracy% of 17 and 20 met ≤15%, respectively. In addition, fifteen compounds showed ≤15% recovery% for certificated reference materials. Intraclass correlation coefficients of the comparison between the current methods and new methods in this study were 0.952 (p-value<0.001) and 0.911 (p-value<0.001) for urinary cadmium and mercury, respectively. Conclusion: This study proposes an efficient simultaneous methodology that can analyze multi elements in smaller sample amounts. More reproduction experiments are needed in the future.

Abstract

Objectives: This study developed and validated an analysis method of urinary metals and metalloids that can be applied inductively with coupled plasma mass spectrometry (ICP-MS). Methods: 0.3 mL of urine was used to analyze 25 metal and metalloid compounds using ICP-MS. The validation of the analytical method included linearity, accuracy, precision, and the calculation of detection limits. In addition, a comparison test was performed with the graphite furnace atomic absorption spectrometry (GF-AAS) method, which is the current standard method, with urine samples of 66 healthy subjects. Results: The linearities (R2 ) of calibration curves of all 25 compounds were ≥ 0.999. Of the 25 compounds, the intra-day and inter-day accuracy% of 17 and 20 met ≤15%, respectively. In addition, fifteen compounds showed ≤15% recovery% for certificated reference materials. Intraclass correlation coefficients of the comparison between the current methods and new methods in this study were 0.952 (p-value<0.001) and 0.911 (p-value<0.001) for urinary cadmium and mercury, respectively. Conclusion: This study proposes an efficient simultaneous methodology that can analyze multi elements in smaller sample amounts. More reproduction experiments are needed in the future.

참고문헌 (30)

  1. Angerer J, "Human biomonitoring:state of the art", Int J Hyg Environ Health, 210(3-4), pp.201~228 (2007)
  2. Angerer J, "Human biomonitoring assessment values : approaches and data requirements", Int J Hyg Environ Health, 214(5), pp.348~360 (2011)
  3. Kim S, "Application of biomonitoring to activities on environmental health and recommendations for Korean National Environmental Health Survey", The Korean Journal of Public Health, 52(1), pp.59~74 (2015)
  4. Lee JH, "Korea National Survey for environmental pollutants in the human body 2008: heavy metals in the blood urine of the Korean population", Int J Environ Health, 215(4), pp.449~457 (2012)
  5. 박충희, "국민환경보건기초조사의 현황 및 전망", 한국환경보건학회지, 40(1), pp.1~9 (2014), 한국환경보건학회[DOI]
  6. Becker K, "German Environmental Survey (GerES): human biomonitoring as a tool to identify exposure pathways", Int J Hyg Environ Health, 210(3-4), pp.267~269 (2007)
  7. Haines DA, "An overview of human biomonitoring of environmental chemicals in the Canadian Health Measures Survey: 2007-2019", Int J Hyg Environ Health, 220(2), pp.13~28 (2017)
  8. Awata H, "Biomarker Levels of Toxic Metals among Asian Populations in the United States : NHANES 2011-2012", Environ Health Perspect, 125(3), pp.306~313 (2017)
  9. Butler O, "Atomic spectrometry updates : a 25-year retrospective", J Anal At Spectrom, 25(10), pp.1546~1566 (2010)
  10. Fukui Y, "Comparative evaluation of GFAAS and ICP-MS for analyses of cadmium in blood", Ind Health, 49(3), pp.338~343 (2011)
  11. Basu N, "Mercury levels in pregnant women, children, and seafood from Mexico City", Environ Res, 135, pp.63~39 (2014)
  12. Vriens A, "Exposure to Environmental Pollutants and Their Association with Biomarkers of Aging: A Multipollutant Approach", Environ Sci Technol (2019)[DOI]
  13. Goullé JP, "Current role of ICP-MS in clinical toxicology and forensic toxicology : a metallic profile", Bioanalysis, 6(17), pp.2245~2259 (2014)
  14. 권정연, "흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교", 한국환경보건학회지, 44(5), pp.491~501 (2018), 한국환경보건학회
  15. Goullé JP, "Metal and metalloid multielementary ICP-MS validation in whole blood, plasma, urine and hair. Reference values", Forensic Sci Int, 153(1), pp.39~44 (2005)
  16. Caldwell KL, "Inductively coupled plasma mass spectrometry to measure multiple toxic elements in urine in NHANES 1999-2000", Atomic Spectroscopy, 26(1), pp.1~7 (2005)
  17. Haines DA, "An overview of human biomonitoring of environmental chemicals in the Canadian Health Measures Survey: 2007-2019", Int J Hyg Environ Health, 220(2), pp.13~28 (2017)
  18. CDC, "Laboratory Procedure Manual-Urine Multi-Element ICP-DRC-MS", CDC Method No. 3018.6-02 (15element panel) and 3018A.4-02 (total arsenic). NHANES 2015-2016, 91~ (2016)
  19. 김금희, "환경분야 시험 · 검사방법의 유효성 검증 기법 연구", 환경분석과 독성보건, 21(2), pp.87~94 (2018), 한국환경분석학회
  20. Ministry of Food and Drug Safety, "Guideline on bioanalytical method validation", 40~ (2013)
  21. A manual for analysis of environmental pollutants in the human specimen, "National Institute of Environmental Research", NIER, 302~, pp.NIER GOVP1200717001 (2006)
  22. Kong KA, "Statistical methods : reliability assessment and method comparison", Ewha Med J, 40(1), pp.9~16 (2017)
  23. Becker K, "German Environmental Survey 1998(GerES III) : environmental pollutants in the urine of the German population", Int J Hyg Environ Health, 206(1), pp.15~24 (2003)
  24. Fukui Y, "Comparative evaluation of GFAAS and ICP-MS for analyses of cadmium in blood", Ind Health, 49(3), pp.338~343 (2011)
  25. Lee W, "A study of analytical method for trace metal ions in whole blood and urine by inductively coupled plasma-mass spectrometry using solid-liquid extraction technique", Anal Sci Technol, 11(4), pp.281~291 (1998)
  26. Establishment of analytical methods for blood and urine using ICP, "MS (II)", Kim YH, 2009, pp.62~, NIER 2009-01-1057
  27. 이수연, "유도결합플라즈마질량분석기를 이용한 체내 미량금속 분석", Annals of Laboratory Medicine, 24(6), pp.362~370 (2004), 대한진단검사의학회
  28. Trzcinka-Ochocka M, "Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters", J Clin Lab Anal, 30(2), pp.130~139 (2016)
  29. DeBord DG, "Use of the"Exposome"in the Practice of Epidemiology : A Primer on-Omic Technologies", Am J Epidemiol, 184(4), pp.302~314 (2016)
  30. Palmer CD, "Determination of lead, cadmium and mercury in blood for assessment of environmental exposure : A comparison between inductively coupled plasma-mass spectrometry and atomic absorption spectrometry", Spectrochimica Acta Part B, 61, pp.980~990 (2006)

관련 논문AI추천

바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가오세림, 오은하, 임호섭, 차상원, 한상범한국환경보건학회 · 한국환경보건학회지2021 · 제47권 제1호환경 바이오모니터링에서의 혈중 중금속 분석 숙련도 시험을 위한 표준물질 제조 및 적용성 평가김소영, 김현정, 문찬석, 양민호, 오세림, 이정섭, 이종화, 이채관, 임호섭, 정호준, 조용민한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제6호흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교강민경, 권정연, 김병권, 김유미, 서정욱, 임현주, 홍영습한국환경보건학회 · 한국환경보건학회지2018 · 제44권 제5호흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교강민경, 권정연, 김병권, 김유미, 서정욱, 임현주, 홍영습한국환경보건학회 · 한국환경보건학회지2019 · 제45권 제3호FI-HG-AAS를 이용한 전처리 과정에서 사용되는 예비환원제의 종류에 따른 요중 비소 분석결과 비교배문주, 조용민, 최승현, 최재욱한국환경보건학회 · 한국환경보건학회지2015 · 제41권 제5호혈장 중 극미량 납 분석을 위한 ICP-MS 분석법 검증김남수, 김용순, 신호상, 안병준, 이병국, 이성배, 이용훈한국분석과학회 · 분석과학2015 · 제28권 제5호

이 간행물의 다른 논문 (13건)