본문 바로가기
KERD
논문

흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교

Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS)

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GFAAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ±40% of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

Abstract

Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GFAAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ±40% of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

참고문헌 (30)

  1. 김효준, "우리나라 일부 도시와 농촌지역 주민의 혈중 납 및 혈중 카드뮴 농도", 생명과학회지, 19(4), pp.472~478 (2009), 한국생명과학회
  2. Zhang ZW, "Background exposure of urban populations to lead and cadmium: comparison between China and Japan", International Archives of Occupational and Environmental Health, 69(4), pp.273~281 (1997)
  3. Establishment of analytical method for blood and urine using ICP, "MS (I)", Lee JS, 2008, pp.1~86
  4. Torrence KM, "Slurry sampling for the determination of arsenic, cadmium, and lead in mainstream cigarette smoke condensate by graphite furnace–atomic absorption spectrometry and inductively coupled plasma–mass spectrometry", Analytical and Bioanalytical Chemistry, 372(5-6), pp.723~731 (2002)
  5. Trzcinka-Ochocka M, "Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters", Journal of Clinical Laboratory Analysis, 30(2), pp.130~139 (2016)
  6. 이성배, "혈장 중 극미량 납 분석을 위한 ICP-MS 분석법 검증", 분석과학, 28(5), pp.309~316 (2015), 한국분석과학회[DOI]
  7. Xiao M, "Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry", PeerJ, 5, pp.e2873~ (2017)
  8. 이성배, "유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석", 분석과학, 25(3), pp.190~196 (2012), 한국분석과학회[DOI]
  9. 권정연, "흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교", 한국환경보건학회지, 44(5), pp.491~501 (2018), 한국환경보건학회
  10. 이수연, "유도결합플라즈마질량분석기를 이용한 체내 미량금속 분석", Annals of Laboratory Medicine, 24(6), pp.362~370 (2004), 대한진단검사의학회
  11. Kristiansen J, "Toxic trace element reference levels in blood and urine: influence of gender and lifestyle factors", The Science of the Total Environment, 204(2), pp.147~160 (1997)
  12. Rahil-Khazen R, "Trace element reference values in serum determined by inductively coupled plasma atomic emission spectrometry", Clinical Chemistry and Laboratory Medicine, 38(8), pp.765~772 (2000)
  13. Mortada WI, "Reference intervals of cadmium, lead, and mercury in blood, urine, hair, and nails among resi dents in Mansoura city, Nile delta, Egypt", Environmental Research, 90(2), pp.104~110 (2002)
  14. Kim JM, "Blood Lead, MAnganese, Aluminium and Silicon Concentrations in Korean Adults", Korean Journal of Preventive Medicine, 33(2), pp.157~164 (2000)
  15. Zhang ZW, "Determination of lead and cadmium in food and blood by inductively coupled plasma mass spectrometry: a comparison with graphite furnace atomic absorption spectrometry", ELSEVIER The Science of the Total Environment, 205(2-3), pp.179~187 (1997)
  16. Yedomon B, "Biomonitoring of 29 trace elements in whole blood from inhabitants of Cotonou(Benin)by ICP-MS", Journal of Trace Elements in Medicine and Biology, 43, pp.38~45 (2017)
  17. Nixon DE, "Routine clinical determination of lead, arsenic, cadmium, and thallium in urine and whole blood by inductively coupled plasma mass spectrometry", Spectrochimica Acta Part B : Atomic Spectroscopy, 51(1), pp.13~25 (1996)
  18. White MA, "A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrometry for determination of trace elements in blood and urine from non occupationally exposed populations", Journal of Trace Elements in Medicine and Biology, 13(1-2), pp.93~101 (1999)
  19. Heitland P, "Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS", Journal of Trace Elements in Medicine and Biology, 20(4), pp.253~262 (2006)
  20. Bocca B, "Development of methods for the quantification of essential and toxic elements in human biomonitoring", Ann Ist Super Sanita, 41(2), pp.165~170 (2005)
  21. Heitland P, "Fast, simple and reliable routine determination of 23 elements in urine by ICP-MS", J Anal At Spectrom, 19, pp.1552~1558 (2004)
  22. Kira CS, "Fast and simple multi-element determination of essential and toxic metals in whole blood with quadrupole ICPMS", Journal of Applied Pharmaceutical Science, 4(5), pp.39~45 (2014)
  23. Zhang WS, "Determination of Pb(Lead), Cd(Cadmium), Cr(Chromium), Cu(Copper), and Ni(Nickel)in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry", Journal of food and drug analysis, 24(1), pp.46~55 (2016)
  24. Soares AR, "Development of a simple method for the determination of lead in lipstick using alkaline solubilization and graphite furnace atomic absorption spectrometry", Talanta, 105, pp.272~277 (2013)
  25. Park KS, "A study on the determination of lead in whole blood by ICP", MS, 1997, pp.10(4), 240~245
  26. Nunes JA, "A Simple Method Based on ICP-MS for Estimation of Background Levels of Arsenic, Cadmium, Copper, Manganese, Nickel, Lead, and Selenium in Blood of the Brazilian Population", Journal of Toxicology and Environmental Health, 73(13-14), pp.878~887 (2010)
  27. Hsieh HF, "Lead determination in whole blood by laser ablation coupled with inductively coupled plasma mass spectrometry", Talanta, 79, pp.183~188 (2009)
  28. Gajek R, "Determination of essential and toxic metals in blood by ICP-MS with calibration in synthetic matrix", Analytical Methods, pp.2193~2202 (2013)
  29. Batista BL, "Exploiting dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for sequential determination of trace elements in blood using a dilute-and-shoot procedure", Analytica Chimica Acta, 639(1-2), pp.13~18 (2009)
  30. Iked M, "Cadmium, chromium, lead, manganese and nickel concentrations in blood of women in non-polluted areas in Japan, as determined by inductively coupled plasma-sector field-mass spectrometry", International Archives of Occupational and Environmental Health, 84(2), pp.139~150 (2011)

관련 논문AI추천

이 간행물의 다른 논문 (9건)