Objectives: The method of analyzing urinary arsenic by flow injection hydride generation atomicabsorption spectrometry (FI-HG-AAS) is generally used because it shows relatively greater sensitivity, lowdetection limits, low blocking action, and is simple to operate. In this study, the results of analysisaccording to three pre-reductants commonly used in the FI-HG-AAS method were compared with eachother. Methods: To analyze urinary arsenic, nineteen urine samples were collected from adults aged 43-79 years oldwithout occupational arsenic exposure. Analysis equipment was FI-HG-AAS (AAnalyst 800/FIAS 400, Perkin-Elmer Inc., USA). The three pre-reductants were potassium iodide (KI/AA), C3H7NO2S (L-cysteine), and amixture of KI/AA and L-cysteine (KI/AA&L-cysteine). Results: In the results of the analysis, the recovery rate of the method using KI/AA was 82.3%, 95.7% for Lcysteine,and 123.5% for KI/AA and L-cysteine combined. When compared with the results by use of highperformance liquid chromatography inductively-coupled plasma mass spectrometry (HPLC-ICP-MS), themethod using L-cysteine was the closest to those using HPLC-ICP-MS (98.57 μg/L for HPLC-ICP-MS; 74.96μg/L for L-cysteine; 69.23 μg/L for KI/AA and L-cysteine; 13.06 μg/L for KI/AA) and were significantlycorrelated (R2=0.882). In addition, they showed the lowest coefficient of variation in the results between twolaboratories that applied the same method. Conclusion: The efficiency of hydride generation is considered highly important to the analysis of urinaryarsenic via FI-HG-AAS. This study suggests that using L-cysteine as a pre-reductant may be suitable and themost rational among the FI-Hg-AAS methods using pre-reductants.
Abstract
Objectives: The method of analyzing urinary arsenic by flow injection hydride generation atomicabsorption spectrometry (FI-HG-AAS) is generally used because it shows relatively greater sensitivity, lowdetection limits, low blocking action, and is simple to operate. In this study, the results of analysisaccording to three pre-reductants commonly used in the FI-HG-AAS method were compared with eachother. Methods: To analyze urinary arsenic, nineteen urine samples were collected from adults aged 43-79 years oldwithout occupational arsenic exposure. Analysis equipment was FI-HG-AAS (AAnalyst 800/FIAS 400, Perkin-Elmer Inc., USA). The three pre-reductants were potassium iodide (KI/AA), C3H7NO2S (L-cysteine), and amixture of KI/AA and L-cysteine (KI/AA&L-cysteine). Results: In the results of the analysis, the recovery rate of the method using KI/AA was 82.3%, 95.7% for Lcysteine,and 123.5% for KI/AA and L-cysteine combined. When compared with the results by use of highperformance liquid chromatography inductively-coupled plasma mass spectrometry (HPLC-ICP-MS), themethod using L-cysteine was the closest to those using HPLC-ICP-MS (98.57 μg/L for HPLC-ICP-MS; 74.96μg/L for L-cysteine; 69.23 μg/L for KI/AA and L-cysteine; 13.06 μg/L for KI/AA) and were significantlycorrelated (R2=0.882). In addition, they showed the lowest coefficient of variation in the results between twolaboratories that applied the same method. Conclusion: The efficiency of hydride generation is considered highly important to the analysis of urinaryarsenic via FI-HG-AAS. This study suggests that using L-cysteine as a pre-reductant may be suitable and themost rational among the FI-Hg-AAS methods using pre-reductants.
참고문헌 (23)
- "IARC Working Group on the Evaluation of Carcinogenic Risks to Humans. Arsenic, metals, fibres, and dusts. IARC monographs on the evaluation of carcinogenic risks to humans", World Health Organization, International Agency for Research on Cancer, 100(Pt C), pp.11~ (2012)
- "IARC Working Group on the Evaluation of Carcinogenic Risks to Humans. Some drinking water disinfectants and contaminants, including arsenic. IARC monographs on the evaluation of carcinogenic risks to humans. World Health Organization", International Agency for Research on Cancer, 84 (2004)
- Gehle K, "Case studies in environmental medicine : arsenic toxicity", Agency for Toxic Substances and Disease Registry, 1~42 (2000)
- Tam GK, "Metabolism of inorganic arsenic(74As)in humans following oral ingestion", Toxicol Appl Pharmacol, 50(2), pp.319~322 (1979)
- Vahter M, "Intracellular interaction and metabolic fate of arsenite and arsenate in mice and rabbits", Chem Biol Interact, 47(1), pp.29~44 (1983)
- Hughes MF., "Biomarkers of exposure : a case study with inorganic arsenic", Environ Health Perspect, 114(11), pp.1790~1796 (2006)
- Brima EI, "Understanding arsenic metabolism through a comparative study of arsenic levels in the urine, hair and fingernails of healthy volunteers from three unexposed ethnic groups in the United Kingdom", Toxicol Appl Pharmacol, 216(1), pp.122~130 (2006)
- Marchiset-Ferlay N, "What is the best biomarker to assess arsenic exposure via drinking water?", Environ Int, 39(1), pp.150~171 (2012)
- ATSDR., "Toxicological profile for arsenic. Agency for Toxic Substances and Disease Registry" (2007), Division of Toxicology
- Norin H, "A rapid method for the selective analysis of total urinary metabolites of inorganic arsenic", Scand J Work Environ Health, 7(1), pp.38~44 (1981)
- Human Biomonitoring Commission of the German Federal Environmental Agency, "Substance Monograph:Arsenic - Reference Value in Urine", Bundesgesundheitsbl - Gesundheitsforsch - Gesundheitsschutz, 46(12), pp.1098~1106 (2003)
- Kumar AR, "Mechanism of volatile hydride formation and their atomization in hydride generation atomic absorption spectrometry", Anal Sci, 21(12), pp.1401~1410 (2005)
- Guo T, "Fast automated determination of toxicologically relevant arsenic in urine by flow injection-hydride generation atomic absorption spectrometry", Analytica Chimica Acta, 349(1), pp.313~318 (1997)
- 이종화, "HG-AAS법에 의한 요중 비소의 최적 분석법에 관한 연구", 한국환경보건학회지, 35(5), pp.402~410 (2009), 한국환경보건학회
- Lee JH, "Korea national survey for environmental pollutants in the human body 2008 : heavy metals in the blood or urine of the Korean population", Int J Hyg Environ Health, 215(4), pp.449~457 (2012)
- Park S, "Strong positive associations between seafood, vegetables, and alcohol with blood mercury and urinary arsenic levels in the Korean adult population", Arch Environ Contam Toxicol, 64, pp.160~170 (2013)
- Howard AG, "Cysteine enhancement of the cryogenic trap hydride AAS determination of dissolved arsenic species", Analytica Chimica Acta, 333, pp.89~96 (1996)
- Spevácová V, "Population-based biomonitoring in the Czech Republic : urinary arsenic", J Environ Monit, 4(5), pp.796~798 (2002)
- Shraim A1, "Speciation of arsenic by hydride generation-atomic absorption spectrometry(HG-AAS)in hydrochloric acid reaction medium", Talanta, 50(5), pp.1109~1127 (1996)
- Le XC, "Effect of cysteine on the speciation of arsenic by using hydride generation atomic absorption spectrometry", Analytica Chimica Acta, 285(3), pp.277~285 (1994)
- Schmeisser E, "Volatile analytes formed from arsenosugars : determination by HPLC-HG-ICPMS and implications for arsenic speciation analyses", Anal Chem, 76(2), pp.418~423 (2004)
- Heitland P, "Fast determination of arsenic species and total arsenic in urine by HPLCICP-MS : concentration ranges for unexposed german inhabitants and clinical case studies", J Anal Toxicol, 32(4), pp.308~314 (2008)
- Hinners TA., "Arsenic speciation : Limitations with direct hydride analysis", Analyst, 105(1253), pp.751~755 (1980)