바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가
Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 µL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2 ) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson’s correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.
Abstract
Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 µL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2 ) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson’s correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.
참고문헌 (33)
- Nico Laur, "ICP-MS trace element analysis in serum and whole blood", PLOS ONE, 15(5), pp.e0233357~ (2020), Public Library of Science (PLoS)[DOI]
- Angerer J, "Human biomonitoring assessment values : approaches and data requirements", Int J Hyg Environ Health, 214(5), pp.348~360 (2011)
- Kim S, "Application of biomonitoring to activities on environmental health and recommendations for Korean National Environmental Health Survey", The Korean Journal of Public Health, 52(1), pp.59~74 (2015)
- Lee JH, "Korea National Survey for environmental pollutants in the human body 2008 : heavy metals in the blood urine of the Korean population", Int J Environ Health, 215(4), pp.449~457 (2012)
- 박충희, "국민환경보건기초조사의 현황 및 전망", 한국환경보건학회지, 40(1), pp.1~9 (2014), 한국환경보건학회[DOI]
- Becker K, "German Environmental Survey (GerES): human biomonitoring as a tool to identify exposure pathways", Int J Hyg Environ Health, 210(3-4), pp.267~269 (2007)
- Haines DA, "An overview of human biomonitoring of environmental chemicals in the Canadian Health Measures Survey: 2007-2019", Int J Hyg Environ Health, 220(2 Pt A), pp.13~28 (2017)
- Awata H, "Biomarker Levels of Toxic Metals among Asian Populations in the United States : NHANES 2011-2012", Environ Health Perspect, 125(3), pp.306~313 (2017)
- Butler O, "Atomic spectrometry updates : a 25-year retrospective", J Anal At Spectrom, 25(10), pp.1546~1566 (2010)
- Fukui Y, "Comparative evaluation of GF-AAS and ICPMS for analyses of cadmium in blood", Ind Health, 49(3), pp.338~343 (2011)
- Deanna RJ, "Analysis of whole humna blood for Pb, Cd, Hg, Se and Mn by ICP-DRC-MS for biomonitoring and acute exposures", Talanta, 1(162), pp.114~122 (2017)
- Vriens A, "Exposure to Environmental Pollutants and Their Association with Biomarkers of Aging: A Multipollutant Approach", Environ Sci Technol (2019)[DOI]
- Goullé JP, "Current role of ICP-MS in clinical toxicology and forensic toxicology : a metallic profile", Bioanalysis, 6(17), pp.2245~2259 (2014)
- 권정연, "흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교", 한국환경보건학회지, 44(5), pp.491~501 (2018), 한국환경보건학회
- Goullé JP, "Metal and metalloid multielementary ICP-MS validation in whole blood, plasma, urine and hair. Reference values", Forensic Sci Int, 153(1), pp.39~44 (2005)
- Caldwell KL, "Inductively coupled plasma mass spectrometry to measure multiple toxic elements in urine in NHANES 1999-2000", Atomic Spectroscopy, 26(1), pp.1~7 (2005)
- Haines DA, "An overview of human biomonitoring of environmental chemicals in the Canadian Health Measures Survey: 2007-2019", Int J Hyg Environ Health, 220(2 Pt A), pp.13~28 (2017)
- McShane WJ, "A rugged and transferable methodfor determining blood cadmium, mercury, and lead with inductively coupled plasma-massspectrometry", Spectrochim. Acta Part B:- At. Spectrosc, 63, pp.638~644 (2008)
- Caldwell KL, "Total blood mercuryconcentrations in the US population: 1999-2006", Int. J. Hyg. Environ. Health., 212, pp.588~598 (2009)
- Centers for Disease Control and Prevention, "Laboratory Procedure Manual-Cadmium, Lead, Managanse, Mercury, and Selenium. Blood Metals Panel 3 (BMP3) ICP-DRC-MS. CDC Method NO. DLS 3016.8.04", ~
- National Institute of Environmental Reserch, "Environmental test", inspection QA, NIER NO. 2011-08-1294, pp.2011, ~
- Ministry of Food and Drug Safety, "Guideline on bioanalytical method validation. 11-1471000-000028-01", 40~ (2013)
- National Institute of Environmental Research, "A manual for analysis of environmental pollutants in the human specimen", NIER GOVP1200717001, 302~ (2006)
- Kong KA, "Statistical methods : reliability assessment and method comparison", Ewha Med J, 40(1), pp.9~16 (2017)
- Becker K, "German Environmental Survey 1998(GerES III) : environmental pollutants in the urine of the German population", Int J Hyg Environ Health, 206(1), pp.15~24 (2003)
- Fukui Y, "Comparative evaluation of GF-AAS and ICPMS for analyses of cadmium in blood", Ind Health, 49(3), pp.338~343 (2011)
- Lee W, "A study of analytical method for trace metal ions in whole blood and urine by inductively coupled plasma-mass spectrometry using solid-liquid extraction technique", Anal Sci Technol, 11(4), pp.281~291 (1998)
- Establishment of analytical methods for blood and urine using ICP-MS (II), "Kim YH", Environmental Health Risk Research Department, ~, pp.NIER 2009-01-1057 (2009)
- 이수연, "유도결합플라즈마질량분석기를 이용한 체내 미량금속 분석", Annals of Laboratory Medicine, 24(6), pp.362~370 (2004), 대한진단검사의학회
- Trzcinka-Ochocka M, "Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters", J Clin Lab Anal, 30(2), pp.130~139 (2016)
- DeBord DG, "Use of the"Exposome"in the Practice of Epidemiology : A Primer on-Omic Technologies", Am J Epidemiol, 184(4), pp.302~314 (2016)
- Palmer CD, "Determination of lead, cadmium and mercury in blood for assessment of environmental exposure : A comparison between inductively coupled plasma-mass spectrometry and atomic absorption spectrometry", Spectrochimica Acta Part B, 61, pp.980~990 (2006)
- Ji-Yeon Lee, "The Association of Heavy Metal of Blood and Serum in the Alzheimer’s Diseases", 한국독성학회지, 28(2), pp.93~98 (2012), 한국독성학회[DOI]