본문 바로가기
KERD
논문

흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교

Comparison of Human Blood Cadmium Concentrations using Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS)

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasmamass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: 0.000 µg/L, MDL: 0.06 µg/L) was lower than that of GF-AAS (IDL: 0.085 µg/L, MDL: 0.327 µg/L). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ± 30% of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

Abstract

Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasmamass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: 0.000 µg/L, MDL: 0.06 µg/L) was lower than that of GF-AAS (IDL: 0.085 µg/L, MDL: 0.327 µg/L). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ± 30% of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

참고문헌 (42)

  1. Fukui Y, "Comparative Evaluation of GFAAS and ICP-MS for Analyses of Cadmium in Blood", Ind Health, 49(3), pp.338~343 (2011)[DOI]
  2. Zhang ZW, "Background exposure of urban populations to lead and cadmium: comparison between china and Japan", Int. Arch. Occup. Environ. Health., 69, pp.273~281 (1997)[DOI]
  3. 김효준, "우리나라 일부 도시와 농촌지역 주민의 혈중 납 및 혈중 카드뮴 농도", 생명과학회지, 19(4), pp.472~478 (2009), 한국생명과학회
  4. Lee JS, "Establishment of analytical method for blood and urine using ICP", MS(I), 2008
  5. Study of the exposure to heavy metals in the Korean population, "Kim SH", Samsung Seoul Hospital, ~ (2002)
  6. 이수연, "유도결합플라즈마질량분석기를 이용한 체내 미량금속 분석", Annals of Laboratory Medicine, 24(6), pp.362~370 (2004), 대한진단검사의학회
  7. Kristiansen J, "Toxic trace element reference levels in blood and urine: influence of gender and lifestyle factors", Sci Total Environ, 204(2), pp.147~160 (1997)[DOI]
  8. Rahil-Khazen R, "Trace element reference values in serum determined by inductively coupled plasma atomic emission spectrometry", Clin Chem Lab Med, 38, pp.765~772 (2000)
  9. Khassouani CE, "Blood cadmium concentration in the population of the Rabat area, Morocco", Clin Chim Acta, 302, pp.155~160 (2000)[DOI]
  10. Mortada WI, "Reference intervals of cadmium, lead, and mercury in blood, urine, hair, and nails among residents in Mansoura city, Nile delta, Egypt", Environ Res, 90(2), pp.104~110 (2002)[DOI]
  11. Kim JM, "Blood Lead, MAnganese, Aluminium and Silicon Concentrations in Korean Adults", Korean J Prev Med, 33(2), pp.157~164 (2000)
  12. Lee CR, "Urinary levels of arsenic, cadmium, and zinc of children in ulsan industrial area", Korean J Prev Med, 32(1), pp.1~8 (1999)
  13. Jessilyn T, "Toxicological profile for cadmium", Agency for toxic substances and disease registry, ~ (1999)
  14. Zhang ZW, "Determination of lead and cadmium in food and blood by inductively coupled plasma mass spectrometry: a comparison with graphite furnace atomic absorption spectrometry", Sci Total Environ, 205, pp.179~187 (1997)[DOI]
  15. Trzcinka-Ochocka M, "Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters", J. Clin. Lab. Anal., 30(2), pp.130~139 (2016)[DOI]
  16. Yedomon B, "Biomonitoring of 29 trace elements in whole blood from inhabitants of Cotonou (Benin) by ICP-MS", J Trace Elem Med Biol, 43, pp.38~45 (2017)[DOI]
  17. Xiao M, "Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry", PeerJ (2017)
  18. Zhong WS, "Determination of Pb (Lead), Cd (Cadmium), Cr(Chromium), Cu (Copper), and Ni (Nickel) in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry", Journal of food and drug analysis, 24(1), pp.46~55 (2016)[DOI]
  19. Soares AR, "Development of a simple method for the determination of lead in lipstick using alkaline solubilization and graphite furnace atomic absorption spectrometry", Talanta, 105, pp.272~277 (2013)[DOI]
  20. Jones DR, "Analysis of whole human blood for Pb, Cd, Hg, Se, and Mn by ICPDRC- MS for biomonitoring and acute exposures", Talanta, 162, pp.114~122 (2017)[DOI]
  21. Palmer CD, "Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma-mass spectrometry and atomic absorption spectrometry", Spectrochimica Acta Part B, 61, pp.980~990 (2006)[DOI]
  22. Nixon DE, "Routine clinical determination of lead, arsenic, cadmium, and thallium in urine and whole blood by inductively coupled plasma mass spectrometry", Spectrochimica Acta Part B, 51, pp.13~25 (1996)[DOI]
  23. White MA, "A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrometry for determination of trace elements in blood and urine from non occupationally exposed populations", J Trace Elements Med Biol, 13, pp.93~101 (1999)[DOI]
  24. Heitland P, "Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS", J Trace Elem Med Biol, 20(4), pp.253~262 (2006)[DOI]
  25. Bocca B, "Development of methods for the quantification of essential and toxic elements in human biomonitoring", Ann Ist Super Sanita, 41(2), pp.165~170 (2005)
  26. Heitland P, "Fast, simple and reliable routine determination of 23 elements in urine by ICP-MS", J Anal At Spectrom, 19, pp.1552~1558 (2004)[DOI]
  27. Kira CS, "Fast and simple multi-element determination of essential and toxic metals in whole blood with quadrupole ICPMS", J App Pharm Sci, 4(5), pp.39~45 (2014)
  28. Torrence KM, "Slurry sampling for the determination of arsenic, cadmium, and lead in mainstream cigarette smoke condensate by graphite furnace-atomic absorption spectrometry and inductively coupled plasma-mass spectrometry", Anal Bioanal Chem, 372, pp.723~731 (2002)[DOI]
  29. Al-Rmalli SW, "Blood cadmium concentrations in general population of Tripoli region, Libya", IOSR-JAC, 8(7), pp.76~80 (2015)
  30. Madiha B, "Determination of Heavy Metal Toxicity in Blood and Health Effect by AAS (Detection of Heavy Metals and its Toxicity in Human Blood)", Arch Nano Op Acc J, 1(2), pp.22~28 (2018)
  31. Chen X, "The association between serum vitamin D levels and renal tubular dysfunction in a general population exposed to cadmium in China", PLOS ONE, 13(4), pp.1~11 (2018)
  32. Kim HJ, "Blood and urine cadmium concentrations and walking speed in middle-aged and older U.S. adults", Environmental Pollution, 232, pp.97~104 (2018)[DOI]
  33. Park HR, "The Monitoring of Heavy Metals in Human Bloods of Middle School Students", J. Fd Hyg. Safety., 20(2), pp.83~88 (2005)
  34. 이미화, "The Blood Cadmium and Lead Levels in Students", 대한의생명과학회지, 12(4), pp.371~374 (2006), 대한의생명과학회
  35. 오정숙, "혈중 납, 수은, 카드뮴 농도와 노출관련 인자", 한국산학기술학회논문지, 16(3), pp.2089~2099 (2015), 한국산학기술학회[DOI]
  36. 김영아, "국민건강영양조사 제4기 2차년도 (2008)를 이용한 어패류 섭취빈도에 따른 한국 성인의 혈중 중금속 농도 조사", Journal of Nutrition and Health, 44(6), pp.518~526 (2011), 한국영양학회
  37. Lee JM, "Association between Heavy Metal Exposure and Prevalence of Metabolic Syndrome in Adults of South Korea", Korean J Fam Pract, 7(2), pp.172~178 (2017)[DOI]
  38. 엄상용, "제련소 주변 지역 주민들의 혈중 중금속 농도와 혈압과의 관련성", 농촌의학.지역보건, 42(1), pp.13~23 (2017), 한국농촌의학.지역보건학회[DOI]
  39. 서정욱, "국민건강영양조사 자료를 활용한 혈 중 납과 카드뮴의 고혈압과의 관련성", 한국환경보건학회지, 44(4), pp.380~390 (2018), 한국환경보건학회
  40. 유인영, "한국 성인의 혈중 납, 수은, 카드뮴 농도와 대사 증후군", 한국생활환경학회지, 21(2), pp.251~259 (2014), 한국생활환경학회
  41. 임호섭, "환경 바이오모니터링에서의 혈중 중금속 분석 숙련도 시험을 위한 표준물질 제조 및 적용성 평가", 한국환경보건학회지, 42(6), pp.450~464 (2016), 한국환경보건학회
  42. Lee KJ, "Preparation and analysis of lyophilized whole blood as external quality control materials for Pb and Cd determination by graphite furnace atomic absorption spectrometry", Journal of the Korean Society of Analytical Sciences, 8(3), pp.134~140 (1995)

관련 논문AI추천

이 간행물의 다른 논문 (9건)