본문 바로가기
KERD
논문KCI 등재

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acidenhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of 9° and 13° were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of 13° during the same delayed time were significantly higher than those of the HBP with an FA of 9° in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with 9° FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a 13° FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a 13° FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a 13° FA represents a feasible option without a significant decrease in image quality.

Abstract

Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acidenhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of 9° and 13° were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of 13° during the same delayed time were significantly higher than those of the HBP with an FA of 9° in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with 9° FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a 13° FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a 13° FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a 13° FA represents a feasible option without a significant decrease in image quality.

참고문헌 (25)

  1. Kim BS, "Body MR imaging: fast, efficient, and comprehensive", Radiol Clin North Am, 52, pp.623~636 (2014)
  2. Semelka RC, "Magnetic resonance imaging of the liver: how I do it", J Gastroenterol Hepatol, 21, pp.632~637 (2006)
  3. Semelka RC, "Contrast agents for MR imaging of the liver", Radiology, 218, pp.27~38 (2001)[DOI]
  4. Rofsky NM, "Abdominal MR imaging with a volumetric interpolated breath-hold examination", Radiology, 212, pp.876~884 (1999)[DOI]
  5. Yu MH, "Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging", J Magn Reson Imaging, 38, pp.1020~1026 (2013)[DOI]
  6. Kim BS, "New imaging strategies using a motion-resistant liver sequence in uncooperative patients", Biomed Res Int, 2014, pp.142658~ (2014)
  7. Wright KL, "Clinical evaluation of CAIPIRINHA: comparison against a GRAPPA standard", J Magn Reson Imaging, 39, pp.189~194 (2014)[DOI]
  8. Park YS, "Usefulness of controlled aliasing in parallel imaging results in higher acceleration in gadoxetic acid-enhanced liver magnetic resonance imaging to clarify the hepatic arterial phase", Invest Radiol, 49, pp.183~188 (2014)[DOI]
  9. Huppertz A, "Improved detection of focal liver lesions at MR imaging: multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings", Radiology, 230, pp.266~275 (2004)[DOI]
  10. Seale MK, "Hepatobiliary-specific MR contrast agents: role in imaging the liver and biliary tree", Radiographics, 29, pp.1725~1748 (2009)[DOI]
  11. Goodwin MD, "Diagnostic challenges and pitfalls in MR imaging with hepatocyte-specific contrast agents", Radiographics, 31, pp.1547~1568 (2011)[DOI]
  12. Sofue K, "Gd-EOB-DTPA-enhanced 3.0 T MR imaging: quantitative and qualitative comparison of hepatocyte-phase images obtained 10 min and 20 min after injection for the detection of liver metastases from colorectal carcinoma", Eur Radiol, 21, pp.2336~2343 (2011)[DOI]
  13. Motosugi U, "Delay before the hepatocyte phase of Gd-EOB-DTPA-enhanced MR imaging: is it possible to shorten the examination time?", Eur Radiol, 19, pp.2623~2629 (2009)[DOI]
  14. Haradome H, "Gadoxetic acid disodium-enhanced hepatocyte phase MRI: can increasing the flip angle improve focal liver lesion detection?", J Magn Reson Imaging, 35, pp.132~139 (2012)[DOI]
  15. Bashir MR, "Liver MRI in the hepatocyte phase with gadolinium-EOB-DTPA: does increasing the flip angle improve conspicuity and detection rate of hypointense lesions", J Magn Reson Imaging, 35, pp.611~616 (2012)[DOI]
  16. Bashir MR, "Improved liver lesion conspicuity by increasing the flip angle during hepatocyte phase MR imaging", Eur Radiol, 21, pp.291~294 (2011)[DOI]
  17. Cho ES, "Feasibility of 5-minute delayed transition phase imaging with 30 degrees flip angle in gadoxetic acid-enhanced 3D gradientecho MRI of liver, compared with 20-minute delayed hepatocyte phase MRI with standard 10 degrees flip angle", AJR Am J Roentgenol, 204, pp.69~75 (2015)[DOI]
  18. Chang KJ, "3.0-T MR imaging of the abdomen: comparison with 1.5 T", Radiographics, 28, pp.1983~1998 (2008)[DOI]
  19. Erturk SM, "Use of 3.0-T MR imaging for evaluation of the abdomen", Radiographics, 29, pp.1547~1563 (2009)[DOI]
  20. Kim S, "Effect of flip angle for optimization of image quality of gadoxetate disodium-enhanced biliary imaging at 1.5 T", AJR Am J Roentgenol, 200, pp.90~96 (2013)[DOI]
  21. Bashir MR, "Optimal timing and diagnostic adequacy of hepatocyte phase imaging with gadoxetate-enhanced liver MRI", Acad Radiol, 21, pp.726~732 (2014)[DOI]
  22. van Kessel CS, "MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation", Eur Radiol, 22, pp.2153~2160 (2012)[DOI]
  23. Kim SH, "Gadoxetic acid-enhanced MRI versus triple-phase MDCT for the preoperative detection of hepatocellular carcinoma", AJR Am J Roentgenol, 192, pp.1675~1681 (2009)[DOI]
  24. Kim HY, "Clinical factors predictive of insufficient liver enhancement on the hepatocyte-phase of Gd-EOB-DTPA-enhanced magnetic resonance imaging in patients with liver cirrhosis", J Gastroenterol, 48, pp.1180~1187 (2013)[DOI]
  25. Kanki A, "Hepatic parenchymal enhancement at Gd-EOB-DTPA-enhanced MR imaging: correlation with morphological grading of severity in cirrhosis and chronic hepatitis", Magn Reson Imaging, 30, pp.356~360 (2012)[DOI]

관련 논문AI추천

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)- Enhanced MR Imaging of the Liver고명주, 고수연, 김두리, 김봉수, 김승형, 송병철, 이경렬, 이무숙, 이정섭, 최국명대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제2호Focal Liver Lesion Detection in Gadoxeic Acid-enhanced Liver MRI : Effects of Scan Delay, Hepatic Fuction, and Magnetic Field Strength김기황, 김명진, 김화선, 박미숙, 임준석, 정용은, 정재준대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2011 · 제15권 제3호Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breathhold Imaging Sequences김기황, 김주희, 유정식, 정재준, 조경은대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2010 · 제14권 제1호Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교김영근, 이세지대한방사선과학회 · Journal of Radiological Science and Technology2015 · 제38권 제2호Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver김윤철대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2019 · 제23권 제1호Usefulness of Gadobenate Dimeglumine - Enhanced Hepatobiliary Phase MR Imaging on Predicting Histological Grade of Hepatocellular Carcinoma김기황, 김명진, 박성호, 임준석, 최진영대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2011 · 제15권 제3호

이 간행물의 다른 논문 (9건)