Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.
Abstract
Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.
참고문헌 (61)
- Gomaa AI, "Hepatocellular carcinoma: epidemiology, risk factors and pathogenesis", World J Gastroenterol, 14, pp.4300~4308 (2008)
- Mittal S, "Epidemiology of hepatocellular carcinoma: consider the population", J Clin Gastroenterol, 47 Suppl, pp.S2~S6 (2013)
- Ringe KI, "Gadoxetate disodium-enhanced MRI of the liver: part 1, protocol optimization and lesion appearance in the noncirrhotic liver", AJR Am J Roentgenol, 195, pp.13~28 (2010)
- Cruite I, "Gadoxetate disodium-enhanced MRI of the liver: part 2, protocol optimization and lesion appearance in the cirrhotic liver", AJR Am J Roentgenol, 195, pp.29~41 (2010)
- Bruix J, "Management of hepatocellular carcinoma:an update", Hepatology, 53, pp.1020~1022 (2011)
- Nakamura S, "Timing of the hepatic arterial phase at Gd-EOB-DTPA-enhanced hepatic dynamic MRI: comparison of the test-injection and the fixed-time delay method", J Magn Reson Imaging, 38, pp.548~554 (2013)
- Pietryga JA, "Respiratory motion artifact affecting hepatic arterial phase imaging with gadoxetate disodium: examination recovery with a multiple arterial phase acquisition", Radiology, 271, pp.426~434 (2014)
- Saranathan M, "DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging", J Magn Reson Imaging, 35, pp.1484~1492 (2012)
- Hope TA, "Improvement of gadoxetate arterial phase capture with a high spatio-temporal resolution multiphase three-dimensional SPGR-Dixon sequence", J Magn Reson Imaging, 38, pp.938~945 (2013)
- Ichikawa S, "Ring-like enhancement of hepatocellular carcinoma in gadoxetic acid-enhanced multiphasic hepatic arterial phase imaging with differential subsampling with cartesian ordering", Invest Radiol, 53, pp.191~199 (2018)
- Clarke SE, "High resolution multi-arterial phase MRI improves lesion contrast in chronic liver disease", Clin Invest Med, 38, pp.E90~E99 (2015)
- Ikram NS, "Multiple arterial phase MRI of arterial hypervascular hepatic lesions: improved arterial phase capture and lesion enhancement", Abdom Radiol (NY), 42, pp.870~876 (2017)
- Fujinaga Y, "Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver:advantages over Cartesian VIBE in the arterial phase", Eur Radiol, 24, pp.1290~1299 (2014)
- Chandarana H, "Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling", Invest Radiol, 48, pp.10~16 (2013)
- Feng L, "Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI", Magn Reson Med, 72, pp.707~717 (2014)
- Feng L, "XD-GRASP: Golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing", Magn Reson Med, 75, pp.775~788 (2016)
- Chandarana H, "Respiratory motionresolved compressed sensing reconstruction of freebreathing radial acquisition for dynamic liver magnetic resonance imaging", Invest Radiol, 50, pp.749~756 (2015)
- Choi JY, "CT and MR imaging diagnosis and staging of hepatocellular carcinoma: part I. Development, growth, and spread: key pathologic and imaging aspects", Radiology, 272, pp.635~654 (2014)
- Choi JY, "CT and MR imaging diagnosis and staging of hepatocellular carcinoma: part II. Extracellular agents, hepatobiliary agents, and ancillary imaging features", Radiology, 273, pp.30~50 (2014)
- Motosugi U, "Hepatobiliary MR contrast agents in hypovascular hepatocellular carcinoma", J Magn Reson Imaging, 41, pp.251~265 (2015)
- 윤정희, "Triple Arterial Phase MR Imaging with Gadoxetic Acid Using a Combination of Contrast Enhanced Time Robust Angiography, Keyhole, and Viewsharing Techniques and Two-Dimensional Parallel Imaging in Comparison with Conventional Single Arterial Phase", Korean Journal of Radiology, 17(4), pp.522~532 (2016), 대한영상의학회[DOI]
- Davenport MS, "Dose-toxicity relationship of gadoxetate disodium and transient severe respiratory motion artifact", AJR Am J Roentgenol, 203, pp.796~802 (2014)
- 허지미, "Troubleshooting Arterial-Phase MR Images of Gadoxetate Disodium-Enhanced Liver", Korean Journal of Radiology, 16(6), pp.1207~1215 (2015), 대한영상의학회[DOI]
- Davenport MS, "Comparison of acute transient dyspnea after intravenous administration of gadoxetate disodium and gadobenate dimeglumine: effect on arterial phase image quality", Radiology, 266, pp.452~461 (2013)
- Davenport MS, "Matched within-patient cohort study of transient arterial phase respiratory motion-related artifact in MR imaging of the liver: gadoxetate disodium versus gadobenate dimeglumine", Radiology, 272, pp.123~131 (2014)
- Yoon JH, "Evaluation of transient motion during gadoxetic acid-enhanced multiphasic liver magnetic resonance imaging using free-breathing goldenangle radial sparse parallel magnetic resonance imaging", Invest Radiol, 53, pp.52~61 (2018)
- Min JH, "Artifacts during the arterial phase of gadoxetate disodium-enhanced MRI: multiple arterial phases using view-sharing from two different vendors versus single arterial phase imaging", Eur Radiol, 28, pp.3335~3346 (2018)
- Hope TA, "Combined parenchymal and vascular imaging: high spatiotemporal resolution arterial evaluation of hepatocellular carcinoma", J Magn Reson Imaging, 43, pp.859~865 (2016)
- Lustig M, "Sparse MRI: the application of compressed sensing for rapid MR imaging", Magn Reson Med, 58, pp.1182~1195 (2007)
- Kaltenbach B, "Dynamic liver magnetic resonance imaging in free-breathing:feasibility of a cartesian T1-weighted acquisition technique with compressed sensing and additional self-navigation signal for hard-gated and motion-resolved reconstruction", Invest Radiol, 52, pp.708~714 (2017)
- Weiss J, "Self-gated 4D-MRI of the liver: initial clinical results of continuous multiphase imaging of hepatic enhancement", J Magn Reson Imaging, 47, pp.459~467 (2018)
- Peters DC, "Centering the projection reconstruction trajectory: reducing gradient delay errors", Magn Reson Med, 50, pp.1~6 (2003)
- Block KT, "Advanced methods for radial data sampling in MRI", Ph.D., pp.2008
- Block KT, "Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint", Magn Reson Med, 57, pp.1086~1098 (2007)
- Song HK, "Dynamic MRI with projection reconstruction and KWIC processing for simultaneous high spatial and temporal resolution", Magn Reson Med, 52, pp.815~824 (2004)
- Winkelmann S, "An optimal radial profile order based on the golden ratio for time-resolved MRI", IEEE Trans Med Imaging, 26, pp.68~76 (2007)
- Chan RW, "The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI", Magn Reson Med, 67, pp.363~377 (2012)
- Hedderich DM, "Clinical evaluation of free-breathing contrast-enhanced T1w MRI of the Liver using pseudo golden angle radial k-space sampling", Rofo, 190, pp.601~609 (2018)
- Kajita K, "Thin-slice free-breathing pseudo-golden-angle radial stack-of-stars with gating and tracking T1-weighted acquisition: an efficient gadoxetic acid-enhanced hepatobiliary-phase imaging alternative for patients with unstable breath holding", Magn Reson Med Sci, 18, pp.4~11 (2019)
- Brodsky EK, "High-spatial and high-temporal resolution dynamic contrast-enhanced perfusion imaging of the liver with time-resolved threedimensional radial MRI", Magn Reson Med, 71, pp.934~941 (2014)
- Block KT, "Spiral imaging: a critical appraisal", J Magn Reson Imaging, 21, pp.657~668 (2005)
- Agrawal MD, "Improved hepatic arterial phase MRI with 3-second temporal resolution", J Magn Reson Imaging, 37, pp.1129~1136 (2013)
- Xu B, "Fast 3D contrast enhanced MRI of the liver using temporal resolution acceleration with constrained evolution reconstruction", Magn Reson Med, 69, pp.370~381 (2013)
- Breuer FA, "Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging", Magn Reson Med, 53, pp.684~691 (2005)
- Breuer FA, "Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)", Magn Reson Med, 55, pp.549~556 (2006)
- Kim BS, "New imaging strategies using a motion-resistant liver sequence in uncooperative patients", Biomed Res Int, 2014, pp.142658~ (2014)
- Wright KL, "Clinical evaluation of CAIPIRINHA: comparison against a GRAPPA standard", J Magn Reson Imaging, 39, pp.189~194 (2014)
- Michaely HJ, "CAIPIRINHADixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution", Invest Radiol, 48, pp.590~597 (2013)
- Yu MH, "Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging", J Magn Reson Imaging, 38, pp.1020~1026 (2013)
- Park YS, "Usefulness of controlled aliasing in parallel imaging results in higher acceleration in gadoxetic acid-enhanced liver magnetic resonance imaging to clarify the hepatic arterial phase", Invest Radiol, 49, pp.183~188 (2014)
- Beck GM, "Contrast-enhanced timing robust acquisition order with a preparation of the longitudinal signal component (CENTRA plus) for 3D contrast-enhanced abdominal imaging", J Magn Reson Imaging, 27, pp.1461~1467 (2008)
- Eggers H, "Chemical shift encoding-based water-fat separation methods", J Magn Reson Imaging, 40, pp.251~268 (2014)
- Eggers H, "Dual-echo Dixon imaging with flexible choice of echo times", Magn Reson Med, 65, pp.96~107 (2011)
- Berglund J, "Two-point dixon method with flexible echo times", Magn Reson Med, 65, pp.994~1004 (2011)
- Benkert T, "Free-breathing volumetric fat", water separation by combining radial sampling, compressed sensing, and parallel imaging, 2017, pp.78, 565~576
- Pandharipande PV, "Perfusion imaging of the liver: current challenges and future goals", Radiology, 234, pp.661~673 (2005)
- Thng CH, "Perfusion magnetic resonance imaging of the liver", World J Gastroenterol, 16, pp.1598~1609 (2010)
- Sourbron S, "Combined quantification of liver perfusion and function with dynamic gadoxetic acid-enhanced MR imaging", Radiology, 263, pp.874~883 (2012)
- Chen Y, "Free-breathing liver perfusion imaging using 3-dimensional through-time spiral generalized autocalibrating partially parallel acquisition acceleration", Invest Radiol, 50, pp.367~375 (2015)
- Chandarana H, "Estimating liver perfusion from free-breathing continuously acquired dynamic gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced acquisition with compressed sensing reconstruction", Invest Radiol, 50, pp.88~94 (2015)
- Hammernik K, "Learning a variational network for reconstruction of accelerated MRI data", Magn Reson Med, 79, pp.3055~3071 (2018)
