본문 바로가기
KERD
논문KCI 등재

Focal Liver Lesion Detection in Gadoxeic Acid-enhanced Liver MRI : Effects of Scan Delay, Hepatic Fuction, and Magnetic Field Strength

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Objective: To determine the effects of scan delay, hepatic function, and magnetic field strength on the performance of gadoxetic acid enhanced magnetic resonance imaging. Materials and Methods: Gadoxetic acid enhanced MRI conducted in 72 patients with 10 minutes and 20 minutes delay were reviewed retrospectively. For quantitative analysis, liver-to-lesion signal difference ratio (SDR) was measured and compared according to scan delay time, hepatic function and magnetic field strength. For qualitative analysis, two board-certificated radiologists reviewed 10-minute delay and 20-minute delay images. The sensitivity and specificity of each reader was compared. Results: The SDR of 20-minute images in non-cirrhotic patients was significantly higher (p < 0.01) than that of 10-minute delay images. However, in cirrhotic patients, it was comparable (p > 0.05) to 10-min delay images. In comparisons according to the magnetic strength, there was no significant difference between 1.5-T and 3.0-T systems. Comparisons of ROC curves showed no statistically significant differences in sensitivity and specificity between 10-minute and 20-minute delay images. Conclusion: An increase in the liver-to-lesion signal difference ratio was dependent on the patients’ hepatic function but not dependent on the magnetic strength. There was no significant difference in sensitivity or specificity between the 10-minute and 20-minute delay images.

Abstract

Objective: To determine the effects of scan delay, hepatic function, and magnetic field strength on the performance of gadoxetic acid enhanced magnetic resonance imaging. Materials and Methods: Gadoxetic acid enhanced MRI conducted in 72 patients with 10 minutes and 20 minutes delay were reviewed retrospectively. For quantitative analysis, liver-to-lesion signal difference ratio (SDR) was measured and compared according to scan delay time, hepatic function and magnetic field strength. For qualitative analysis, two board-certificated radiologists reviewed 10-minute delay and 20-minute delay images. The sensitivity and specificity of each reader was compared. Results: The SDR of 20-minute images in non-cirrhotic patients was significantly higher (p < 0.01) than that of 10-minute delay images. However, in cirrhotic patients, it was comparable (p > 0.05) to 10-min delay images. In comparisons according to the magnetic strength, there was no significant difference between 1.5-T and 3.0-T systems. Comparisons of ROC curves showed no statistically significant differences in sensitivity and specificity between 10-minute and 20-minute delay images. Conclusion: An increase in the liver-to-lesion signal difference ratio was dependent on the patients’ hepatic function but not dependent on the magnetic strength. There was no significant difference in sensitivity or specificity between the 10-minute and 20-minute delay images.

참고문헌 (14)

  1. Weinmann HJ, "A new lipophilic gadolinium chelate as a tissue-specific contrast medium for MRI", Magn Reson Med, 22, pp.233~237 (1991)
  2. Schuhmann-Giampieri G, "Preclinical evaluation of Gd-EOB-DTPA as a contrast agent in MR imaging of the hepatobiliary system", Radiology, 183, pp.59~64 (1992)
  3. Schuhmann-Giampieri G, "Pharmacokinetics of the liver-specific contrast agent Gd-EOB-DTPA in relation to contrast-enhanced liver imaging in humans", J Clin Pharmacol, 37, pp.587~596 (1997)
  4. Muhler A, "Biodistribution and excretion of 153Gd-labeled gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid following repeated intravenous administration to rats", Acad Radiol, 2, pp.313~318 (1995)
  5. Clement O, "Gadolinium-ethoxybenzyl-DTPA, a new liver-specific magnetic resonance contrast agent. Kinetic and enhancement patterns in normal and cholestatic rats", Invest Radiol, 27, pp.612~619 (1992)
  6. Hun-Kyu Ryeom, "Quantitative Evaluation of Liver Function with MRI Using Gd-EOB-DTPA", Korean Journal of Radiology, 5(4), pp.231~239 (2004), 대한영상의학회
  7. Tschirch FT, "Contrast-enhanced MR cholangiography with Gd-EOB-DTPA in patients with liver cirrhosis: visualization of the biliary ducts in comparison with patients with normal liver parenchyma", Eur Radiol, 18, pp.1577~1586 (2008)
  8. Yamada A, "Quantitative evaluation of liver function with use of gadoxetate disodium-enhanced MR imaging", Radiology, 260, pp.727~733 (2011)
  9. Sofue K, "Gd-EOB-DTPA-enhanced 3.0 T MR imaging: quantitative and qualitative comparison of hepatocyte-phase images obtained 10 min and 20 min after injection for the detection of liver metastases from colorectal carcinoma", Eur Radiol, 21, pp.2336~2343 (2011)
  10. Tamada T, "Gd-EOB-DTPA-enhanced MR imaging: Evaluation of hepatic enhancement effects in normal and cirrhotic livers", Eur J Radiol, 80, pp.e311~e316 (2011)
  11. Tamada T, "Gd-EOB-DTPA enhanced MR imaging: Evaluation of biliary and renal excretion in normal and cirrhotic livers", Eur J Radiol, 80, pp.e207~e211 (2011)
  12. Hamm B, "Phase I clinical evaluation of Gd-EOB-DTPA as a hepatobiliary MR contrast agent: safety, pharmacokinetics, and MR imaging", Radiology, 195, pp.785~792 (1995)
  13. Abe Y, "The Toll-like receptor 3-mediated antiviral response is important for protection against poliovirus infection in poliovirus receptor transgenic mice", J Virol (2011)
  14. Iwasaki H, "The IkappaB kinase complex regulates the stability of cytokine-encoding mRNA induced by TLR-IL-1R by controlling degradation of regnase-1", Nat Immunol, 12(12), pp.1167~1175 (2011)

관련 논문AI추천

Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교김영근, 이세지대한방사선과학회 · Journal of Radiological Science and Technology2015 · 제38권 제2호Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)- Enhanced MR Imaging of the Liver고명주, 고수연, 김두리, 김봉수, 김승형, 송병철, 이경렬, 이무숙, 이정섭, 최국명대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제2호Usefulness of Gadobenate Dimeglumine - Enhanced Hepatobiliary Phase MR Imaging on Predicting Histological Grade of Hepatocellular Carcinoma김기황, 김명진, 박성호, 임준석, 최진영대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2011 · 제15권 제3호Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breathhold Imaging Sequences김기황, 김주희, 유정식, 정재준, 조경은대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2010 · 제14권 제1호Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE ImagingBong Soo Kim, Guk Myung Choi, Ho Kyu Lee, Jeongjae Kim, Jeong Sub Lee, Joon Hyuk Park, Kyung Ryeol Lee, Mu Sook Lee, Seung Hyoung Kim, Seung Tae Woo대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2018 · 제22권 제1호Gadoxetic acid-enhanced magnetic resonance imaging: Hepatocellular carcinoma and mimickers박미숙, Jin-Young Choi, Khalid Suliman Aljoqiman, Myeong-Jin Kim, Yeun-Yoon Kim대한간학회 · Clinical and Molecular Hepatology2019 · 제25권 제3호

이 간행물의 다른 논문 (9건)