A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose : To efficiently evaluate phased array coil performance using a software tool box with which we can make visualcomparison of the sensitivity of every coil element between the real experiment and EM simulation. Materials and Methods: We have developed a C++- and MATLAB-based software tool called Phased Array Coil Evaluator(PACE). PACE has the following functions: Building 3D models of the coil elements, importing the FDTD simulation results,and visualizing the coil sensitivity of each coil element on the ordinary Cartesian coordinate and the relative coil positioncoordinate. To build a 3D model of the phased array coil, we used an electromagnetic 3D tracker in a stylus form. Aftermaking the 3D model, we imported the 3D model into the FDTD electromagnetic field simulation tool. Results: An accurate comparison between the coil sensitivity simulation and real experiment on the tool box platform hasbeen made through fine matching of the simulation and real experiment with aids of the 3D tracker. In the simulationand experiment, we used a 36-channel helmet-style phased array coil. At the 3D MRI data acquisition using the spoiledgradient echo sequence, we used the uniform cylindrical phantom that had the same geometry as the one in the FDTDsimulation. In the tool box, we can conveniently choose the coil element of interest and we can compare the coil sensitivitieselement-by-element of the phased array coil. Conclusion: We expect the tool box can be greatly used for developing phased array coils of new geometry or for periodicmaintenance of phased array coils in a more accurate and consistent manner.
Abstract
Purpose : To efficiently evaluate phased array coil performance using a software tool box with which we can make visualcomparison of the sensitivity of every coil element between the real experiment and EM simulation. Materials and Methods: We have developed a C++- and MATLAB-based software tool called Phased Array Coil Evaluator(PACE). PACE has the following functions: Building 3D models of the coil elements, importing the FDTD simulation results,and visualizing the coil sensitivity of each coil element on the ordinary Cartesian coordinate and the relative coil positioncoordinate. To build a 3D model of the phased array coil, we used an electromagnetic 3D tracker in a stylus form. Aftermaking the 3D model, we imported the 3D model into the FDTD electromagnetic field simulation tool. Results: An accurate comparison between the coil sensitivity simulation and real experiment on the tool box platform hasbeen made through fine matching of the simulation and real experiment with aids of the 3D tracker. In the simulationand experiment, we used a 36-channel helmet-style phased array coil. At the 3D MRI data acquisition using the spoiledgradient echo sequence, we used the uniform cylindrical phantom that had the same geometry as the one in the FDTDsimulation. In the tool box, we can conveniently choose the coil element of interest and we can compare the coil sensitivitieselement-by-element of the phased array coil. Conclusion: We expect the tool box can be greatly used for developing phased array coils of new geometry or for periodicmaintenance of phased array coils in a more accurate and consistent manner.
참고문헌 (15)
- Roemer PB, "The NMR phased array", Magn Reson Med, 16, pp.192~225 (1990)
- Lee RF, "Coupling and decoupling theory and its application to the MRI phased array", Magn Reson Med, 48, pp.203~213 (2002)
- Keil B, "Massively parallel MRI detector arrays", J Magn Reson, 229, pp.75~89 (2013)
- Wong EY, "Computer simulations for optimization of design parameters for intravascular imaging microcoil construction", Proc Intl Soc Mag Reson Med, 11, pp.2386~ (2003)
- Constantinides C, "Intercomparison of performance of RF coil geometries for high field mouse cardiac MRI", Concepts Magn Reson Part A, 38A, pp.236~252 (2011)
- Hernandez D, "A bi-planar surface coil for parietal lobe imaging", Proc Intl Soc Mag Reson Med, 21, pp.2793~ (2013)
- Kim DE, "Retrospective 3D modeling of RF coils using a 3D tracker for EM simulation", Concepts Magn Reson Part B, 43, pp.126~132 (2013)
- Wiggins GC, "32-channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry", Magn Reson Med, 56, pp.216~223 (2006)
- Lattanzi R, "Performance evaluation of a 32-element head array with respect to the ultimate intrinsic SNR", NMR Biomed, 23, pp.142~151 (2010)
- Hoult DI, "The principle of reciprocity in signal strength calculations-A mathematical guide", Concepts Magn Reson Part A, 12, pp.173~187 (2000)
- Hartwig V, "Computational analysis of a radiofrequency knee coil for low-field MRI using FDTD", Applied Magn Reson, 44, pp.389~400 (2013)
- Darrasse L, "Quick measurement of NMR-coil sensitivity with a dual-loop probe", Review Scientific Instruments, 64, pp.1841~1844 (1993)
- "SEMCAD X MRI"[URL]
- Griswold MA, "Partially parallel imaging with localized sensitivities (PILS)", Magn Reson Med, 44, pp.602~609 (2000)
- Seiberlich N, "Parallel imaging in angiography. Magnetic Resonance Angiography", pp.188~ (2012), Springer
