Dipole Element Evaluation of 8-Channel Arrays for Human Head Imaging at 10.5 Tesla MRI
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
'Purpose: To optimize B1 + (transmit magnetic field generated by radiofrequency coils) and specific absorption ratio (SAR) efficiency for human head imaging at 10.5 tesla (T) with various 8-channel dipole antenna element arrays. Materials and Methods: Electromagnetic simulations were employed to model threedimensional arrays including 8-channel half-wave, fractionated, meander-ends, and inductor- shortened dipole antennas. The B1 + efficiency and SAR efficiency were evaluated using a cylindrical phantom and a human model for human head imaging. The B1 + efficiency, peak 10 g SAR, and SAR efficiency values of different dipole antenna arrays, including inductorshortened dipole arrays with coaxial cables additionally, were summarized and compared for practical applications. Results: The inductor-shortened dipole antenna array demonstrated the highest SAR efficiency values among the arrays with cylindrical phantoms. In the human model, the fractionated dipole showed the highest B1 + efficiency values, whereas the inductorshortened dipole antenna array exhibited superior SAR efficiency compared to the other dipole antenna arrays. Further, simulation data with and without coaxial cables indicated that the inductor-shortened dipole antenna array without cables exhibited a 9.2% higher B1 + efficiency and 14.6% lower peak 10 g SAR than the array with cables. Consequently, the SAR efficiency of the inductor-shortened dipole antenna array without coaxial cables was 14.9% higher than that with coaxial cables. Conclusion: The inductor-shortened dipole antenna array demonstrated higher SAR efficiency with low SAR values for human brain imaging at 10.5 T. Consequently, the optimization of the coaxial cable setup further enhanced its suitability for ultra-high field applications.
Abstract
'Purpose: To optimize B1 + (transmit magnetic field generated by radiofrequency coils) and specific absorption ratio (SAR) efficiency for human head imaging at 10.5 tesla (T) with various 8-channel dipole antenna element arrays. Materials and Methods: Electromagnetic simulations were employed to model threedimensional arrays including 8-channel half-wave, fractionated, meander-ends, and inductor- shortened dipole antennas. The B1 + efficiency and SAR efficiency were evaluated using a cylindrical phantom and a human model for human head imaging. The B1 + efficiency, peak 10 g SAR, and SAR efficiency values of different dipole antenna arrays, including inductorshortened dipole arrays with coaxial cables additionally, were summarized and compared for practical applications. Results: The inductor-shortened dipole antenna array demonstrated the highest SAR efficiency values among the arrays with cylindrical phantoms. In the human model, the fractionated dipole showed the highest B1 + efficiency values, whereas the inductorshortened dipole antenna array exhibited superior SAR efficiency compared to the other dipole antenna arrays. Further, simulation data with and without coaxial cables indicated that the inductor-shortened dipole antenna array without cables exhibited a 9.2% higher B1 + efficiency and 14.6% lower peak 10 g SAR than the array with cables. Consequently, the SAR efficiency of the inductor-shortened dipole antenna array without coaxial cables was 14.9% higher than that with coaxial cables. Conclusion: The inductor-shortened dipole antenna array demonstrated higher SAR efficiency with low SAR values for human brain imaging at 10.5 T. Consequently, the optimization of the coaxial cable setup further enhanced its suitability for ultra-high field applications.
참고문헌 (37)
- Ernst RR, "Principles of nuclear magnetic resonance in one and two dimensions" (1987), Clarendon Press
- Guérin B, "The ultimate signal-to-noise ratio in realistic body models", Magn Reson Med, 78, pp.1969~1980 (2017)
- Dumoulin SO, "Ultra-high field MRI : advancing systems neuroscience towards mesoscopic human brain function", Neuroimage, 168, pp.345~357 (2018)
- Ugurbil K, "Magnetic resonance imaging at ultrahigh fields", IEEE Trans Biomed Eng, 61, pp.1364~1379 (2014)
- Ug˘urbil K, "Imaging at ultrahigh magnetic fields : history, challenges, and solutions", Neuroimage, 168, pp.7~32 (2018)
- He X, "First in-vivo human imaging at 10. 5T : imaging the body at 447 MHz", Magn Reson Med, 84, pp.289~303 (2020)
- Sadeghi-Tarakameh A, "In vivo human head MRI at 10. 5T : a radiofrequency safety study and preliminary imaging results", Magn Reson Med, 84, pp.484~496 (2020)
- Kang CK, "Intracranial microvascular imaging at 7 T MRI with transceiver RF coils", Magn Reson Imaging, 32, pp.1133~1138 (2014)
- Kang CK, "Magnetic resonance imaging apparatus with spirally extended monopole antenna structure", United States patent US 10488474, ~ (2019)
- Moser E, "7-T MR--from research to clinical applications?", NMR Biomed, 25, pp.695~716 (2012)
- Ogawa S, "Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model", Biophys J, 64, pp.803~812 (1993)
- Ogawa S, "An approach to probe some neural systems interaction by functional MRI at neural time scale down to milliseconds", Proc Natl Acad Sci U S A, 97, pp.11026~11031 (2000)
- Ertürk MA, "Toward imaging the body at 10. 5 tesla", Magn Reson Med, 77, pp.434~443 (2017)
- Fujita H, "New horizons in MR technology : RF coil designs and trends", Magn Reson Med Sci, 6, pp.29~42 (2007)
- Balanis CA, "Antenna theory: analysis and design" (2016), John Wiley & Sons
- Nikolova NK, "Introduction to microwave imaging" (2017), Cambridge University Press
- Wang C, "B1 field, SAR, and SNR comparisons for birdcage, TEM, and microstrip coils at 7T", J Magn Reson Imaging, 24, pp.439~443 (2006)
- Adriany G, "A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla", Magn Reson Med, 63, pp.1478~1485 (2010)
- Vaughan JT, "7T vs. 4T : RF power, homogeneity, and signal-to-noise comparison in head images", Magn Reson Med, 46, pp.24~30 (2001)
- Lattanzi R, "Ideal current patterns yielding optimal signal-to-noise ratio and specific absorption rate in magnetic resonance imaging : computational methods and physical insights", Magn Reson Med, 68, pp.286~304 (2012)
- Lattanzi R, "Approaching ultimate intrinsic signal-to-noise ratio with loop and dipole antennas", Magn Reson Med, 79, pp.1789~1803 (2018)
- Raaijmakers AJ, "Design of a radiative surface coil array element at 7 T : the single-side adapted dipole antenna", Magn Reson Med, 66, pp.1488~1497 (2011)
- Raaijmakers AJ, "The fractionated dipole antenna : a new antenna for body imaging at 7 tesla", Magn Reson Med, 75, pp.1366~1374 (2016)
- Avdievich NI, "A 32-element loop", dipole hybrid array for human head imaging at 7 T, 2022, pp.88, 1912~1926
- Avdievich NI, "Bent folded-end dipole head array for ultrahigh-field MRI turns"dielectric resonance"from an enemy to a friend", Magn Reson Med, 84, pp.3453~3467 (2020)
- "29-channel receive-only dense dipole head array for 7T MRI"[URL]
- "A 16-channel transceiver loop+dipole antennas head array for human head imaging at 10.5T"[URL]
- Woo MK, "Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10. 5 tesla", IEEE Access, 8, pp.203555~203563 (2020)
- Woo MK, "Evaluation of 8-channel radiative antenna arrays for human head imaging at 10. 5 tesla", Sensors(Basel), 21, pp.6000~ (2021)
- Woo MK, "A 16-channel dipole antenna array for human head magnetic resonance imaging at 10. 5 tesla", Sensors(Basel), 21, pp.7250~ (2021)
- Woo MK, "A monopole and dipole hybrid antenna array for human brain imaging at 10. 5 tesla", IEEE Antennas Wirel Propag Lett, 21, pp.1857~1861 (2022)
- Woo MK, "Extended monopole antenna array with individual shield(EMAS)coil : an improved monopole antenna design for brain imaging at 7 tesla MRI", Magn Reson Med, 75, pp.2566~2572 (2016)
- Christ A, "The virtual family--development of surface-based anatomical models of two adults and two children for dosimetric simulations", Phys Med Biol, 55, pp.N23~N38 (2010)
- Woo MK, "Comparison of 16-channel asymmetric sleeve antenna and dipole antenna transceiver arrays at 10. 5 tesla MRI", IEEE Trans Med Imaging, 40, pp.1147~1156 (2021)
- "Antenna system guide, NIJ guide 202–00"[URL]
- Lee RF, "Coupling and decoupling theory and its application to the MRI phased array", Magn Reson Med, 48, pp.203~213 (2002)
- Woo MK, "A 32-channel sleeve antenna receiver array for human head MRI applications at 10. 5 T", IEEE Trans Med Imaging, 42, pp.2643~2652 (2023)
