The RF shimming technique has been used to improve the transmit RF field homogeneity in highfield MRI. In the RF shimming technique, the amplitude and phase of the driving currents in each coil element are optimized to get homogenous flip angle or uniform image intensity. The inductive and capacitive coupling between the coil elements may degrade the RF field homogeneity if not taken into account in the optimization procedure. In this paper, we have analyzed the coupling effects on the RF shimming using a sixteen-element TEM RF coil model operating at 300 MHz. We have found that the coupling effects on the RF shimming can be reduced by putting high dielectric material between the active rung and the shield.

Abstract

The RF shimming technique has been used to improve the transmit RF field homogeneity in highfield MRI. In the RF shimming technique, the amplitude and phase of the driving currents in each coil element are optimized to get homogenous flip angle or uniform image intensity. The inductive and capacitive coupling between the coil elements may degrade the RF field homogeneity if not taken into account in the optimization procedure. In this paper, we have analyzed the coupling effects on the RF shimming using a sixteen-element TEM RF coil model operating at 300 MHz. We have found that the coupling effects on the RF shimming can be reduced by putting high dielectric material between the active rung and the shield.

참고문헌 (8)

  1. Bottomley P, "RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging", Phys Med Biol, 23, pp.630~643 (1978)
  2. Glover GH, "Comparison of linear and circular-polarization for magnetic-resonance imaging", J Magn Reson, 64, pp.255~270 (1985)
  3. Zhu Y, "Parallel excitation on an eight transmit-channel MRI system", pp.14~ (2005), Proce- edings of the 13th Annual Meeting of the ISMRM, Miami Beach, FL, USA
  4. Adriany G, "Transmit and receive transmission line arrays for 7 Tesla parallel imaging", Magn Reson Med, 53, pp.433~444 (2005)
  5. Hoult DI, "The NMR multi-transmit phased array: a Cartesian feedback approach", J Magn Reson, 171, pp.64~70 (2004)
  6. Collins CM, "Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high freque- ncies", Magn Reson Med, 54, pp.1327~1332 (2005)
  7. Mao W, "Exploring the limits of RF shimming for high-field MRI of the human head", Magn Reson Med, 56, pp.918~922 (2006)
  8. Collins CM, "Array-optimized composite pulse for excellent whole brain homogeneity in high-field MRI", Magn Reson Med, 57, pp.470~474 (2007)