본문 바로가기
KERD
논문KCI 등재

Influence of a glide path on the dentinal crack formation of ProTaper Next system

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path. Materials and Methods: Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teeth, which were divided into 2 groups (n = 15): Group PG/PTN, glide path was created with ProGlider (PG) and then canals were shaped with PTN system; Group PTN, glide path was not prepared and canals were shaped with PTN system only. All roots were sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the apex, and the sections were observed under a stereomicroscope. The presence/absence of cracks was recorded. Data were analyzed with chi-square tests with Yates correction. Results: There were no significant differences in crack formation between the PTN with and without glide path preparation. The incidence of cracks observed in PG/PTN and PTN groups was 17.8% and 28.9%, respectively. Conclusions: The creation of a glide path with ProGlider before ProTaper Next rotary system did not influence dentinal crack formation in root canals.

Abstract

Objectives: The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path. Materials and Methods: Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teeth, which were divided into 2 groups (n = 15): Group PG/PTN, glide path was created with ProGlider (PG) and then canals were shaped with PTN system; Group PTN, glide path was not prepared and canals were shaped with PTN system only. All roots were sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the apex, and the sections were observed under a stereomicroscope. The presence/absence of cracks was recorded. Data were analyzed with chi-square tests with Yates correction. Results: There were no significant differences in crack formation between the PTN with and without glide path preparation. The incidence of cracks observed in PG/PTN and PTN groups was 17.8% and 28.9%, respectively. Conclusions: The creation of a glide path with ProGlider before ProTaper Next rotary system did not influence dentinal crack formation in root canals.

참고문헌 (22)

  1. Berutti E, "Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
  2. Patiño PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
  3. Berutti E, "Root canal anatomy preservation of WaveOne reciprocating files with or without glide path", J Endod, 38, pp.101~104 (2012)
  4. Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
  5. Elnaghy AM, "Evaluation of root canal transportation, centering ratio, and remaining dentin thickness associated with ProTaper Next instruments with and without glide path", J Endod, 40, pp.2053~2056 (2014)
  6. Uroz-Torres D, "Effectiveness of a manual glide path on the preparation of curved root canals by using Mtwo rotary instruments", J Endod, 35, pp.699~702 (2009)
  7. Zanette F, "Apical root canal transportation and remaining dentin thickness associated with ProTaper Universal with and without PathFile", J Endod, 40, pp.688~693 (2014)
  8. Ehrhardt IC, "Assessment of the separation incidence of mtwo files used with preflaring:prospective clinical study", J Endod, 38, pp.1078~1081 (2012)
  9. Bier CA, "The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation", J Endod, 35, pp.236~238 (2009)
  10. Yoldas O, "Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file", J Endod, 38, pp.232~235 (2012)
  11. Hin ES, "Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall", J Endod, 39, pp.262~264 (2013)
  12. Liu R, "Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths", J Endod, 39, pp.129~132 (2013)
  13. Schäfer E, "Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth", J Endod, 28, pp.211~216 (2002)
  14. Shemesh H, "The effects of canal preparation and filling on the incidence of dentinal defects", Int Endod J, 42, pp.208~213 (2009)
  15. Pasqualini D, "Computed micro-tomographic evaluation of glide path with nickel-titanium rotary PathFile in maxillary first molars curved canals", J Endod, 38, pp.389~393 (2012)
  16. Pasqualini D, "Postoperative pain after manual and mechanical glide path: a randomized clinical trial", J Endod, 38, pp.32~36 (2012)
  17. 하정홍, "Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals", Restorative Dentistry and Endodontics, 37(4), pp.215~219 (2012), 대한치과보존학회[DOI]
  18. Kansal R, "Assessment of dentinal damage during canal preparation using reciprocating and rotary files", J Endod, 40, pp.1443~1446 (2014)
  19. Arslan H, "Effect of ProTaper Universal, Endoflare, Revo-S, HyFlex coronal flaring instruments, and Gates Glidden drills on crack formation", J Endod, 40, pp.1681~1683 (2014)
  20. Capar ID, "Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin", J Endod, 40, pp.1482~1484 (2014)
  21. Karataş E, "Dentinal crack formation during root canal preparations by the twisted file adaptive, ProTaper Next, ProTaper Universal, and WaveOne Instruments", J Endod, 41, pp.261~264 (2015)
  22. Çiçek E, "Evaluation of microcrack formation in root canals after instrumentation with different NiTi rotary file systems:a scanning electron microscopy study", Scanning, 37, pp.49~53 (2015)

관련 논문AI추천

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals박상신, 하정홍대한치과보존학회 · Restorative Dentistry and Endodontics2012 · 제37권 제4호Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instrumentsGülşah Uslu, Koray Yılmaz, Taha Özyürek, Vildan Tek대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제4호Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium filesGülşah Uslu, Uğur İnan대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제2호Effect of repetitive pecking at working length for glide path preparation using G-file김성교, 김현철, 장석우, 전효진, 하정홍, Rashid El Abed대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제2호Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systemsAnand Sherwood Inbaraj, Ernest Prince Prakasam, Ramyadharshini Tamilkumaran, Vaanjay Murugadoss, Vigneshwar V Shanmugham대한치과보존학회 · Restorative Dentistry and Endodontics2020 · 제45권 제2호Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구곽상원, 김현철, 하정홍대한치과의사협회 · 대한치과의사협회지2017 · 제55권 제10호