Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals
2
조회
0
다운로드
13
인용
0
참고문헌
키워드
초록
Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer)were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect (2.796 ± 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.
Abstract
Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer)were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect (2.796 ± 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.
참고문헌 (20)
- Walia HM, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
- Glossen CR, "A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments", J Endod, 21, pp.146~151 (1995)
- Yun HH, "A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.228~233 (2003)
- 하정홍, "COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL", Restorative Dentistry and Endodontics, 35(4), pp.267~272 (2010), 대한치과보존학회
- Malueg LA, "Examination of external apical root resorption with scanning electron microscopy", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 82, pp.89~93 (1996)
- Sjogren U, "Factors affecting the long-term results of endodontic treatment", J Endod, 16, pp.498~504 (1990)
- Smith CS, "Factors influencing the success of conventional root canal therapy-a five-year retrospective study", Int Endod J, 26, pp.321~333 (1993)
- Swartz DB, "Twenty years of endodontic success and failure", J Endod, 9, pp.198~202 (1983)
- Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
- Diemer F, "Effect of pitch length on the behavior of rotary triple helix root canal instruments", J Endod, 30, pp.716~718 (2004)
- Berutti E, "Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
- Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
- Patiño PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
- 성헤진, "Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal", Restorative Dentistry and Endodontics, 35(5), pp.380~386 (2010), 대한치과보존학회
- Di Fiore PM, "A dozen ways to prevent nickel-titanium rotary instrument fracture", J Am Dent Assoc, 138, pp.196~201 (2007)
- Gulabivala K, "The influence of interfacial forces and duration of filing on root canal shaping", Endod Dent Traumatol, 16, pp.166~174 (2000)
- Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests", J Endod, 28, pp.448~451 (2002)
- Gabel WP, "Effect of rotational speed on nickel-titanium file distortion", J Endod, 25, pp.752~754 (1999)
- Gambarini G, "Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors", J Endod, 27, pp.772~774 (2001)
- Schrader C, "Analysis of torque and force with differently tapered rotary endodontic instruments in vitro", J Endod, 31, pp.120~123 (2005)
