본문 바로가기
KERD
논문KCI 등재

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

2

조회

0

다운로드

13

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer)were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect (2.796 ± 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Abstract

Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer)were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect (2.796 ± 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

참고문헌 (20)

  1. Walia HM, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
  2. Glossen CR, "A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments", J Endod, 21, pp.146~151 (1995)
  3. Yun HH, "A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.228~233 (2003)
  4. 하정홍, "COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL", Restorative Dentistry and Endodontics, 35(4), pp.267~272 (2010), 대한치과보존학회
  5. Malueg LA, "Examination of external apical root resorption with scanning electron microscopy", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 82, pp.89~93 (1996)
  6. Sjogren U, "Factors affecting the long-term results of endodontic treatment", J Endod, 16, pp.498~504 (1990)
  7. Smith CS, "Factors influencing the success of conventional root canal therapy-a five-year retrospective study", Int Endod J, 26, pp.321~333 (1993)
  8. Swartz DB, "Twenty years of endodontic success and failure", J Endod, 9, pp.198~202 (1983)
  9. Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
  10. Diemer F, "Effect of pitch length on the behavior of rotary triple helix root canal instruments", J Endod, 30, pp.716~718 (2004)
  11. Berutti E, "Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
  12. Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
  13. Patiño PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
  14. 성헤진, "Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal", Restorative Dentistry and Endodontics, 35(5), pp.380~386 (2010), 대한치과보존학회
  15. Di Fiore PM, "A dozen ways to prevent nickel-titanium rotary instrument fracture", J Am Dent Assoc, 138, pp.196~201 (2007)
  16. Gulabivala K, "The influence of interfacial forces and duration of filing on root canal shaping", Endod Dent Traumatol, 16, pp.166~174 (2000)
  17. Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests", J Endod, 28, pp.448~451 (2002)
  18. Gabel WP, "Effect of rotational speed on nickel-titanium file distortion", J Endod, 25, pp.752~754 (1999)
  19. Gambarini G, "Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors", J Endod, 27, pp.772~774 (2001)
  20. Schrader C, "Analysis of torque and force with differently tapered rotary endodontic instruments in vitro", J Endod, 31, pp.120~123 (2005)

이 간행물의 다른 논문 (9건)