Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구
Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.
Abstract
Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.
참고문헌 (24)
- Schäfer E, "Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study", J Endod, 30, pp.432~435 (2004)
- Cheung GS, "A retrospective study of endodontic treatment outcome between nickeltitanium rotary and stainless steel hand filing techniques", J Endod, 35, pp.938~943 (2009)
- Setzer FC, "Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences", J Endod, 36, pp.1226~1229 (2010)
- Sonntag D, "Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students", Int Endod J, 36, pp.246~255 (2003)
- Pak JG, "Pain prevalence and severity before, during, and after root canal treatment: a systematic review", J Endod, 37, pp.429~438 (2011)
- Reddy SA, "Apical extrusion of debris using two hand and two rotary instrumentation techniques", J Endod, 24, pp.180~183 (1998)
- Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
- Cheung GS, "Instrument fracture: mechanisms, removal of fragments, and clinical outcomes", Endod Topics, 16, pp.1~26 (2009)
- Arbab-Chirani R, "Comparative analysis of torsional and bending behavior through finite-element models of 5Ni-Ti endodontic instruments", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 111, pp.115~121 (2011)
- Tsujimoto M, "Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties", J Endod, 40, pp.1824~1829 (2014)
- Baek SH, "Comparison of torsional stiffness of nickeltitanium rotary files with different geometric characteristics", J Endod, 37, pp.1283~1286 (2011)
- 하정홍, "Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals", Restorative Dentistry and Endodontics, 37(4), pp.215~219 (2012), 대한치과보존학회[DOI]
- Patino PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
- Berutti E, "Use of nickeltitanium rotary PathFile to create the glide path:comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
- Kwak SW, "Effects of Pitch Length and Heat Treatment on the Mechanical Properties of the Glide Path Preparation Instruments", J Endod, 42, pp.788~792 (2016)
- Ha JH, "Debris extrusion by glide-path establishing endodontic instruments with different geometries", J Dent Sci, 11, pp.136~140 (2016)
- Topcuoglu HS, "Influence of a glide path on apical extrusion of debris during canal preparation using single-file systems in curved canals", Int Endod J, 49, pp.599~603 (2016)
- Borges AH, "The Influence of Cervical Preflaring on the Amount of Apically Extruded Debris after Root Canal Preparation Using Different Instrumentation Systems", J Endod, 42, pp.465~469 (2016)
- Tanalp J, "Apical extrusion of debris: a literature review of an inherent occurrence during root canal treatment", Int Endod J, 47, pp.211~221 (2014)
- Berutti E, "Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider", J Endod, 40, pp.2015~2018 (2014)
- Paleker F, "Glide Path Enlargement of Mandibular Molar Canals by Using K-files, the ProGlider File, and G-Files: A Comparative Study of the Preparation Times", J Endod, 43, pp.609~612 (2017)
- D'Amario M, "Evaluation of a new nickeltitanium system to create the glide path in root canal preparation of curved canals", J Endod, 39, pp.1581~1584 (2013)
- Elnaghy AM, "Evaluation of root canal transportation, centering ratio, and remaining dentin thickness associated with ProTaper Next instruments with and without glide path", J Endod, 40, pp.2053~2056 (2014)
- 하정홍, "Effect of repetitive pecking at working length for glide path preparation using G-file", Restorative Dentistry and Endodontics, 40(2), pp.123~127 (2015), 대한치과보존학회
