Effect of water storage on flexural strength of silorane and methacrylate-based composite resins
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens (2 × 2 × 25 mm) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.
Abstract
Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens (2 × 2 × 25 mm) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.
참고문헌 (22)
- Scotti N, "Microleakage at enamel and dentin margins with a bulk fills flowable resin", Eur J Dent, 8, pp.1~8 (2014)
- Eick JD, "Stability of silorane dental monomers in aqueous systems", J Dent, 34, pp.405~410 (2006)
- Cramer NB, "Recent advances and developments in composite dental restorative materials", J Dent Res, 90, pp.402~416 (2011)
- Sheikh-Al-Eslamian SM, "Effect of decontamination on micro-shear bond strength of silorane-based composite increments", J Investig Clin Dent, 8, pp.e12196~ (2017)
- 김은하, "Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites", Restorative Dentistry and Endodontics, 40(2), pp.128~135 (2015), 대한치과보존학회
- Czasch P, "In vitro comparison of mechanical properties and degree of cure of bulk fill composites", Clin Oral Investig, 17, pp.227~235 (2013)
- Ilie N, "Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance", Oper Dent, 38, pp.618~625 (2013)
- Hirano S, "Creep on a composite resin in water", Dent Mater J, 8, pp.93~99 (1989)
- Garoushi S, "Creep of experimental short fiber-reinforced composite resin", Dent Mater J, 31, pp.737~741 (2012)
- Porto IC, "Mechanical and physical properties of silorane and methacrylate-based composites", J Dent, 41, pp.732~739 (2013)
- Ito S, "Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity", Biomaterials, 26, pp.6449~6459 (2005)
- Giannini M, "Characterization of water sorption, solubility, and roughness of silorane- and methacrylate-based composite resins", Oper Dent, 39, pp.264~272 (2014)
- Kaleem M, "Effect of filler size and morphology on viscoelastic stability of resin-composites under dynamic loading", J Mater Sci Mater Med, 23, pp.623~627 (2012)
- Zhang Y, "Effect of immersion in various media on the sorption, solubility, elution of unreacted monomers, and flexural properties of two model dental composite compositions", J Mater Sci Mater Med, 19, pp.2477~2483 (2008)
- Schmidt C, "The effect of aging on the mechanical properties of nanohybrid composites based on new monomer formulations", Clin Oral Investig, 17, pp.251~257 (2013)
- Asmussen E, "Influence of selected components on crosslink density in polymer structures", Eur J Oral Sci, 109, pp.282~285 (2001)
- El-Safty S, "Creep deformation of restorative resin-composites intended for bulk-fill placement", Dent Mater, 28, pp.928~935 (2012)
- Arrais CA, "Silorane- and high filled-based “lowshrinkage”resin composites: shrinkage, flexural strength and modulus", Braz Oral Res, 27, pp.97~102 (2013)
- Leprince JG, "Progress in dimethacrylate-based dental composite technology and curing efficiency", Dent Mater, 29, pp.139~156 (2013)
- Garoushi S, "Physical properties and depth of cure of a new short fiber reinforced composite", Dent Mater, 29, pp.835~841 (2013)
- Goracci C, "Polymerization efficiency and flexural strength of low-stress restorative composites", Dent Mater, 30, pp.688~694 (2014)
- Chang M, "Physical property evaluation of four composite materials", Oper Dent, 38, pp.E144~E153 (2013)