Bilateral Catastrophic Acetabular Component Failure after Ceramic-on-Polyethylene Total Hip Arthroplasty -A Case Report-
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Ceramic-on-polyethylene components have better wear characteristics than metal-on-polyethylene components in total hip arthroplasty (THA), and thus, extensive wear resulting in penetration of the femoral head through the acetabular cup is rare after ceramic-on-polyethylene THA. However, several reports have been issued regarding catastrophic polyethylene failure in ceramic-on-polyethylene systems. Here, the authors report the first case of bilateral complete polyethylene wear failure with acetabular cup perforation after ceramic-on-polyethylene THA.
Abstract
Ceramic-on-polyethylene components have better wear characteristics than metal-on-polyethylene components in total hip arthroplasty (THA), and thus, extensive wear resulting in penetration of the femoral head through the acetabular cup is rare after ceramic-on-polyethylene THA. However, several reports have been issued regarding catastrophic polyethylene failure in ceramic-on-polyethylene systems. Here, the authors report the first case of bilateral complete polyethylene wear failure with acetabular cup perforation after ceramic-on-polyethylene THA.
참고문헌 (10)
- Clarke IC, "Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-onpolyethylene wear", Clin Orthop Relat Res, (379), pp.34~40 (2000)
- Min BW, "Polyethylene liner failure in second-generation Harris-Galante acetabular components", J Arthroplasty, 20, pp.717~722 (2005)
- Needham J, "Catastrophic failure of ceramic-polyethylene bearing total hip arthroplasty", J Arthroplasty, 23, pp.627~630 (2008)
- Mariconda M, "Complete polyethylene wear-through and secondary breakage of the expansion cup in a ceramic-polyethylene total arthroplasty", Arch Orthop Trauma Surg, 130, pp.61~64 (2010)
- Khan RJ, "The natural history of metallosis from catastrophic failure of a polyethylene liner in a total hip", J Arthroplasty, 24, pp.1144~ (2009)
- Kim YH, "Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective randomized study", J Bone Joint Surg Am, 87, pp.1769~1776 (2005)
- Kim SY, "Total hip arthroplasty with the use of nonmodular cementless acetabular component", J Arthroplasty, 20, pp.632~638 (2005)
- von Schewelov T, "Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis: an analysis of 154 omnifit prostheses with mean 6-year follow-up", Acta Orthop Scand, 75, pp.283~294 (2004)
- Orishimo KF, "Can component and patient factors account for the variance in wear rates among bilateral total hip arthroplasty patients?", J Arthroplasty, 18, pp.154~160 (2003)
- Wan Z, "The influence of acetabular component position on wear in total hip arthroplasty", J Arthroplasty, 23, pp.51~56 (2008)
