본문 바로가기
KERD
논문KCI 등재

Cementless Revision Total Hip Arthroplasty with Ceramic Articulation

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: The results of ceramic-on-ceramic (CoC) bearing surfaces in primary total hip arthroplasty (THA) were well known. However, it was not known in revision THA. The purpose of this study is to report the results of revision THA with ceramic articulation. Materials and Methods: A total of 112 revision THAs were evaluated. The mean age at the time of surgery was 51.6 years (27.7 to 84.2 years). The mean duration of the follow-up periods was 6.3 years (2.3 to 11.4 years). Results: The Harris hip scores improved from an average of 56.2 at the index surgery to an average of 93.3 at the last follow-up (P<0.001). None of hips showed osteolysis or ceramic head fracture. One hip showed aseptic loosening in the acetabular component with squeaking that caused a re-revision. There were nine cases of dislocation. The survivorship at 5 years was 94.5% (95% confidence interval, 87.9% to 97.6%) with revision for any reason as the endpoint and 100% with femoral revision. Conclusion: The ceramic articulation is one of good bearing options for revision THA in patients with a long life expectancy.

Abstract

Purpose: The results of ceramic-on-ceramic (CoC) bearing surfaces in primary total hip arthroplasty (THA) were well known. However, it was not known in revision THA. The purpose of this study is to report the results of revision THA with ceramic articulation. Materials and Methods: A total of 112 revision THAs were evaluated. The mean age at the time of surgery was 51.6 years (27.7 to 84.2 years). The mean duration of the follow-up periods was 6.3 years (2.3 to 11.4 years). Results: The Harris hip scores improved from an average of 56.2 at the index surgery to an average of 93.3 at the last follow-up (P<0.001). None of hips showed osteolysis or ceramic head fracture. One hip showed aseptic loosening in the acetabular component with squeaking that caused a re-revision. There were nine cases of dislocation. The survivorship at 5 years was 94.5% (95% confidence interval, 87.9% to 97.6%) with revision for any reason as the endpoint and 100% with femoral revision. Conclusion: The ceramic articulation is one of good bearing options for revision THA in patients with a long life expectancy.

참고문헌 (28)

  1. Kurtz S, "Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002", J Bone Joint Surg Am, 87, pp.1487~1497 (2005)
  2. Ulrich SD, "Total hip arthroplasties: what are the reasons for revision?", Int Orthop, 32, pp.597~604 (2008)
  3. Pospischill M, "Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years", J Bone Joint Surg Br, 87, pp.1210~1215 (2005)
  4. Zichner L, "In-vivo wear of the slide combinations ceramics-polyethylene as opposed to metalpolyethylene", Orthopade, 26, pp.129~134 (1997)
  5. Amstutz HC, "Mechanism and clinical significance of wear debrisinduced osteolysis", Clin Orthop Relat Res, (276), pp.7~18 (1992)
  6. Brodner W, "Serum cobalt levels after metal-on-metal total hip arthroplasty", J Bone Joint Surg Am, 85(A), pp.2168~2173 (2003)
  7. Hallab N, "Metal sensitivity in patients with orthopaedic implants", J Bone Joint Surg Am, 83(A), pp.428~436 (2001)
  8. Jack CM, "The use of ceramic-on-ceramic bearings in isolated revision of the acetabular component", Bone Joint J, 95(B), pp.333~338 (2013)
  9. Pospischill M, "Strategies for head and inlay exchange in revision hip arthroplasty", Int Orthop, 35, pp.261~265 (2011)
  10. Paprosky WG, "Assessment and classification of bone stock deficiency in revision total hip arthroplasty", Am J Orthop(Belle Mead NJ), 31, pp.459~464 (2002)
  11. Williams VG 2nd, "Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups", J Arthroplasty, 12, pp.25~31 (1997)
  12. Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation", J Bone Joint Surg Am, 51, pp.737~755 (1969)
  13. Jasty M, "Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allografts", J Bone Joint Surg Br, 72, pp.63~67 (1990)
  14. Cadambi A, "Osteolysis of the distal femur after total knee arthroplasty", J Arthroplasty, 9, pp.579~594 (1994)
  15. revisan C, "Bisphosphonate treatment for osteolysis in total hip arthroplasty. A report of four cases", Clin Cases Miner Bone Metab, 10, pp.61~64 (2013)
  16. Tamaki Y, "Massive femoral osteolysis secondary to loosening of a cemented roughened long stem : a case report", Case Rep Orthop, 2014, pp.840267~ (2014)
  17. DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, (121), pp.20~32 (1976)
  18. Engh CA, "Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components", Clin Orthop Relat Res, (257), pp.107~128 (1990)
  19. Melloh M, "Predictors of early stem loosening after total hip arthroplasty : a case-control study", J Orthop Surg(Hong Kong), 19, pp.269~273 (2011)
  20. Lewinnek GE, "Dislocations after total hip-replacement arthroplasties", J Bone Joint Surg Am, 60, pp.217~220 (1978)
  21. Woo RY, "Dislocations after total hip arthroplasty", J Bone Joint Surg Am, 64, pp.1295~1306 (1982)
  22. Murphy SB, "Femoral anteversion", J Bone Joint Surg Am, 69, pp.1169~1176 (1987)
  23. Renkawitz T, "Femoral pinless length and offset measurements during computer-assisted, minimally invasive total hip arthroplasty", J Arthroplasty, 29, pp.1021~1025 (2014)
  24. Murray DW, "Survival analysis of joint replacements", J Bone Joint Surg Br, 75, pp.697~704 (1993)
  25. Han CD, "Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty : minimal 5-year follow-up study", J Arthroplasty, 14, pp.714~723 (1999)
  26. Hooper GJ, "Revision following cemented and uncemented primary total hip replacement : a seven-year analysis from the New Zealand Joint Registry", J Bone Joint Surg Br, 91, pp.451~458 (2009)
  27. Bierbaum BE, "Ceramic-on-ceramic bearings in total hip arthroplasty", Clin Orthop Relat Res, (405), pp.158~163 (2002)
  28. Chang JD, "Thirdgeneration ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty", J Arthroplasty, 24, pp.1231~1235 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (10건)