The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan–Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan–Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.
Abstract
Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan–Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan–Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.
참고문헌 (30)
- Learmonth ID, "The operation of the century : total hip replacement", Lancet, 370, pp.1508~1519 (2007)
- Rajaee SS, "Increasing burden of total hip arthroplasty revisions in patients between 45 and 64 years of age", J Bone Joint Surg Am, 100, pp.449~458 (2018)
- Lachiewicz PF, "Bearing surfaces for total hip arthroplasty", J Am Acad Orthop Surg, 26, pp.45~57 (2018)
- Zagra L, "Bearing surfaces in primary total hip arthroplasty", EFORT Open Rev, 3, pp.217~224 (2018)
- Heckmann ND, "Total hip arthroplasty bearing surface trends in the United States from 2007 to 2014 : the rise of ceramic on polyethylene", J Arthroplasty, 33, pp.1757~1763 (2018)
- Grieco PW, "New alternate bearing surfaces in total hip arthroplasty : a review of the current literature", J Clin Orthop Trauma, 9, pp.7~16 (2018)
- Kim YH, "Eighteen-year results of cementless THA with alumina-on-HXLPE bearings in patients <30 years old : a concise follow-up of a previous report", J Bone Joint Surg Am, 102, pp.1255~1259 (2020)
- 윤필환, "The Epidemiology and National Trends of Bearing Surface Usage in Primary Total Hip Arthroplasty in Korea", Clinics in Orthopedic Surgery, 8(1), pp.029~037 (2016), 대한정형외과학회
- DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, (121), pp.20~32 (1976)
- Gruen TA, ""Modes of failure"of cemented stem-type femoral components : a radiographic analysis of loosening", Clin Orthop Relat Res, (141), pp.17~27 (1979)
- Johnston RC, "Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results", J Bone Joint Surg Am, 72, pp.161~168 (1991)
- Varnum C, "Outcomes of different bearings in total hip arthroplasty-implant survival, revision causes, and patient-reported outcome", Dan Med J, 64, pp.B5350~ (2017)
- Sukur E, "Particle disease : a current review of the biological mechanisms in periprosthetic osteolysis after hip arthroplasty", Open Orthop J, 10, pp.241~251 (2016)
- Peters RM, "The effect of bearing type on the outcome of total hip arthroplasty", Acta Orthop, 89, pp.163~169 (2018)
- Milosˇev I, "Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings", J Bone Joint Surg Am, 94, pp.1756~1763 (2012)
- Min BW, "Highly cross-linked polyethylene in total hip arthroplasty in patients younger than 50 years with osteonecrosis of the femoral head : a minimum of 10 years of follow-up", J Arthroplasty, 35, pp.805~810 (2020)
- Skinner JA, "Ceramics in total hip arthroplasty:a bearing solution?", Bone Joint J, 99-B, pp.993~995 (2017)
- Howard DP, "Ceramic-on-ceramic bearing fractures in total hip arthroplasty:an analysis of data from the National Joint Registry", Bone Joint J, 99-B, pp.1012~1019 (2017)
- 김민욱, "Total Hip Arthroplasty Using Ceramic-on-ceramic Bearing Surfaces: Long-term Assessment of Squeaking Sounds", Hip and Pelvis, 30(1), pp.18~22 (2018), 대한고관절학회[DOI]
- Solarino G, "Results of 200 consecutive ceramic-on-ceramic cementless hip arthroplasties in patients up to 50 years of age : a 5-24 years of follow-up study", J Arthroplasty, 34(7S), pp.S232~S237 (2019)
- Higuchi Y, "Significantly lower wear of ceramic-on-ceramic bearings than metal-on-highly cross-linked polyethylene bearings : a 10-to 14-year follow-up study", J Arthroplasty, 31, pp.1246~1250 (2016)
- Dong YL, "Ceramic on ceramic or ceramic-on-polyethylene for total hip arthroplasty : a systemic review and meta-analysis of prospective randomized studies", Chin Med J(Engl), 128, pp.1223~1231 (2015)
- Amanatullah DF, "Comparison of surgical outcomes and implant wear between ceramic-ceramic and ceramic-polyethylene articulations in total hip arthroplasty", J Arthroplasty, 26(6Suppl), pp.72~77 (2011)
- Kim HS, "Thirdgeneration ceramic-on-ceramic total hip arthroplasty in patients with osteonecrosis of the femoral head: a 10- to 16-year follow-up study", J Bone Joint Surg Am (2021)[DOI]
- Mutimer J, "Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years", Clin Orthop Relat Res, 468, pp.3228~3233 (2010)
- Lee YK, "Effect of neck length on third-generation ceramic head failure; finite element and retrieval analysis", J Orthop Sci, 19, pp.587~597 (2014)
- Lee YK, "Preventing ceramic liner fracture after Delta ceramic-onceramic total hip arthroplasty", Arch Orthop Trauma Surg, 141, pp.1155~1162 (2021)
- Traina F, "Revision of ceramic hip replacements for fracture of a ceramic component : AAOS exhibit selection", J Bone Joint Surg Am, 93, pp.e147~ (2011)
- Blumenfeld TJ, "Fracture of a cross-linked polyethylene liner : a multifactorial issue", J Arthroplasty, 26, pp.666~ (2011)
- Piriou P, "A numerical model to reproduce squeaking of ceramicon-ceramic total hip arthroplasty. Influence of design and material", Orthop Traumatol Surg Res, 102(4 Suppl), pp.S229~S234 (2016)