Primary Total Hip Arthroplasty Using Third Generation Ceramic-Ceramic Articulation: Results after a Minimum of Three-years of Follow-up

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: This study assessed the short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems. Materials and Methods: Two hundred and seventy two patients (294 hips) with primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems who had been followed-up for a minimum of 3 years were included. Clinicoradiological results were analyzed and postoperative complications were observed. Results: At final follow-up, mean Harris hip score was increased from 52 to 94 points. On radiogical evaluation, the average acetabular inclination was 42 degrees and the average acetabular anteversion was 15 degrees. Neither osteolysis nor loosening were observed around the acetabulum or proximal femur. Among 294 acetabular cups, 293 cups (99.66%) achieved stable fixation. Regarding the 294 femoral stems, 286 (97.28%) had bony fixation, 7 (2.38%) had fibrous fixation, and none were found to have unstable stem fixation. Proximal bone resorption was observed in 17 hips (5.78%; only Grade 1) and radiolucent lines were observed in 88 hips (29.93%), however, all were around the distal smooth portion of the stems. Postoperative complications includeddislocation in 6 hips (2.04%), heterotopic ossification in 3 hips (1.02%), ceramic fractures in 4 hips (1.36%), superficial infection in 1 hip (0.34%), and squeaking in 8 hips (2.72%). Conclusion: The short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation and Accolade TMZF femoral stems together with Secur-Fit acetabular cups were satisfactory. However, problems such as ceramic fractures and squeaking after arthroplasty were observed. Additional studies are necessary in order to develop methods that may reduce or eliminate these complications.

Abstract

Purpose: This study assessed the short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems. Materials and Methods: Two hundred and seventy two patients (294 hips) with primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems who had been followed-up for a minimum of 3 years were included. Clinicoradiological results were analyzed and postoperative complications were observed. Results: At final follow-up, mean Harris hip score was increased from 52 to 94 points. On radiogical evaluation, the average acetabular inclination was 42 degrees and the average acetabular anteversion was 15 degrees. Neither osteolysis nor loosening were observed around the acetabulum or proximal femur. Among 294 acetabular cups, 293 cups (99.66%) achieved stable fixation. Regarding the 294 femoral stems, 286 (97.28%) had bony fixation, 7 (2.38%) had fibrous fixation, and none were found to have unstable stem fixation. Proximal bone resorption was observed in 17 hips (5.78%; only Grade 1) and radiolucent lines were observed in 88 hips (29.93%), however, all were around the distal smooth portion of the stems. Postoperative complications includeddislocation in 6 hips (2.04%), heterotopic ossification in 3 hips (1.02%), ceramic fractures in 4 hips (1.36%), superficial infection in 1 hip (0.34%), and squeaking in 8 hips (2.72%). Conclusion: The short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation and Accolade TMZF femoral stems together with Secur-Fit acetabular cups were satisfactory. However, problems such as ceramic fractures and squeaking after arthroplasty were observed. Additional studies are necessary in order to develop methods that may reduce or eliminate these complications.

참고문헌 (35)

  1. Barrack RL, "Concerns about ceramics in THA", Clin Orthop Relat Res, 429, pp.73~79 (2004)
  2. Dorr LD, "Bilateral total hip arthroplasty comparing hydroxyapatite coating to porouscoated fixation", J Arthroplasty, 13, pp.729~736 (1998)
  3. Engh CA, "Porouscoated total hip replacement", Clin Orthop Relat Res, 298, pp.89~96 (1994)
  4. Gruen TA, "'Modes of failure' of cemented stem-type femoral components : a radiographic analysis of loosening", Clin Orthop Relat Res, 141, pp.17~27 (1979)
  5. Callaghan JJ, "The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series", J Bone Joint Surg Am, 70, pp.337~346 (1988)
  6. Boardman DL, "A simple and reliable method of estimating radiographic acetabular anteversion", Proceedings of the 68th Annual Meeting of the American Academy of Orthopaedic Surgeons, pp.497~ (2001), American Academy of Orthopaedic Surgeons
  7. DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, 121, pp.20~32 (1976)
  8. Engh CA, "Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components", Clin Orthop Relat Res, 257, pp.107~128 (1990)
  9. Brooker AF, "Incidence and a method of classification", J Bone Joint Surg Am, 55, pp.1629~1632 (1973)
  10. Older J, "Charnley low-friction arthroplasty : a worldwide retrospective review at 15 to 20 years", J Arthroplasty, 17, pp.675~680 (2002)
  11. Synder M, "Ceramic-ceramic articulation in uncemented total hip arthroplasty", Wiad Lek, 58, pp.193~197 (2005)
  12. Casper DS, "Primary total hip arthroplasty with an uncemented femoral component five-to nine-year results", J Arthroplasty, 26, pp.838~841 (2011)
  13. Issa K, "Radiographic fit and fill analysis of a new second-generation proximally coated cementless stem compared to its predicate design", J Arthroplasty, 29, pp.192~198 (2014)
  14. McLaughlin JR, "Total hip arthroplasty with an uncemented tapered femoral component", J Bone Joint Surg Am, 90, pp.1290~1296 (2008)
  15. Parvizi J, "Primary total hip arthroplasty with an uncemented femoral component : a long-term study of the Taperloc stem", J Arthroplasty, 19, pp.151~156 (2004)
  16. Woolson ST, "Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation. 3 1", 2-year follow-up, 1992, pp.7, 381~388
  17. Hamilton WG, "THA with Delta ceramic on ceramic : results of a multicenter investigational device exemption trial", Clin Orthop Relat Res, 468, pp.358~366 (2010)
  18. Head WC, "The proximal porous coating alternative for primary total hip arthroplasty", Orthopedics, 22, pp.813~815 (1999)
  19. Heekin RD, "The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study", J Bone Joint Surg Am, 75, pp.77~91 (1993)
  20. Kim YH, "Results of the Harris-Galante cementless hip prosthesis", J Bone Joint Surg Br, 74, pp.83~87 (1992)
  21. Archibeck MJ, "Secondgeneration cementless total hip arthroplasty. Eight to eleven-year results", J Bone Joint Surg Am, 83-A, pp.1666~1673 (2001)
  22. Sporer SM, "Biologic fixation and bone ingrowth", Orthop Clin North Am, 36, pp.105~111 (2005)
  23. Keurentjes JC, "High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings", Clin Orthop Relat Res, 466, pp.1438~1443 (2008)
  24. Yang CC, "The squeaking hip : a cause for concern-disagrees", Orthopedics, 30, pp.739~742 (2007)
  25. Walter WL, "Edge loading in third generation alumina ceramic-on-ceramic bearings : stripe wear", J Arthroplasty, 19, pp.402~413 (2004)
  26. Ranawat AS, "The squeaking hip: a cause for concern-agrees", Orthopedics, 30, pp.738~ (2007)
  27. Morlock M, "Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty", J Arthroplasty, 16, pp.1071~1074 (2001)
  28. Walter WL, "Squeaking in ceramic-on-ceramic hips : the importance of acetabular component orientation", J Arthroplasty, 22, pp.496~503 (2007)
  29. Heck DA, "Prosthetic component failures in hip arthroplasty surgery", J Arthroplasty, 10, pp.575~580 (1995)
  30. Yamaguchi M, "The spatial location of impingement in total hip arthroplasty", J Arthroplasty, 15, pp.305~313 (2000)
  31. Maccauro G, "Fracture of a YTZP ceramic femoral head. Analysis of a fault", J Bone Joint Surg Br, 86, pp.1192~1196 (2004)
  32. Masonis JL, "Zirconia femoral head fractures : a clinical and retrieval analysis", J Arthroplasty, 19, pp.898~905 (2004)
  33. Koo KH, "Isolated fracture of the ceramic head after thirdgeneration alumina-on-alumina total hip arthroplasty", J Bone Joint Surg Am, 90, pp.329~336 (2008)
  34. Min BW, "Delayed fracture of a ceramic insert with modern ceramic total hip replacement", J Arthroplasty, 22, pp.136~139 (2007)
  35. Toni A, "Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience", J Bone Joint Surg Am, 88(4), pp.55~63 (2006)

관련 논문AI추천

이 간행물의 다른 논문 (9건)