Purpose: This study presents the clinical and radiological outcomes of cementless total hip arthroplasty using the COREN hip system after a minimum duration of follow-up of 5 years. Materials and Methods: We evaluated the results of a consecutive series of the first 200 primary total hip arthroplasties that had been performed in our hospital in 169 patients between February 2007 and April 2011. Six patients (6 hips) had died within 5 years, and 12 patients (13 hips) had been lost to follow-up, leaving a total of 151 patients (181 hips) available for the study. All patients were evaluated clinically and radiologically with special attention to thigh pain, implant fixation, radiolucent line and osteolysis around implants. Results: The mean Harris hip score improved from 59.4 preoperatively to 97.2 postoperatively. No patient complained of thigh pain. All implants demonstrated radiographic evidence of stable fixation by bone ingrowth without any change in position. No implant was loose radiographically or was revised. Eleven hips (7.7%) had a radiolucent line around the femoral stem. Focal osteolytic area was detected in 3 cases (2.1%). An osteolytic lesion was stabilized in 1 case and further observation was needed in 2 cases in which the lesions were detected several years after surgery. Stress shielding was observed in 80.3% of cases (first degree, 35.9%; second degree, 44.4%); there were no cases of third or fourth degree stress shielding. One case was complicated by bacterial infection and repeated dislocation. Conclusion: Mid-term results of total hip arthroplasty using the COREN hip system are very encouraging clinically and radiologically.
Abstract
Purpose: This study presents the clinical and radiological outcomes of cementless total hip arthroplasty using the COREN hip system after a minimum duration of follow-up of 5 years. Materials and Methods: We evaluated the results of a consecutive series of the first 200 primary total hip arthroplasties that had been performed in our hospital in 169 patients between February 2007 and April 2011. Six patients (6 hips) had died within 5 years, and 12 patients (13 hips) had been lost to follow-up, leaving a total of 151 patients (181 hips) available for the study. All patients were evaluated clinically and radiologically with special attention to thigh pain, implant fixation, radiolucent line and osteolysis around implants. Results: The mean Harris hip score improved from 59.4 preoperatively to 97.2 postoperatively. No patient complained of thigh pain. All implants demonstrated radiographic evidence of stable fixation by bone ingrowth without any change in position. No implant was loose radiographically or was revised. Eleven hips (7.7%) had a radiolucent line around the femoral stem. Focal osteolytic area was detected in 3 cases (2.1%). An osteolytic lesion was stabilized in 1 case and further observation was needed in 2 cases in which the lesions were detected several years after surgery. Stress shielding was observed in 80.3% of cases (first degree, 35.9%; second degree, 44.4%); there were no cases of third or fourth degree stress shielding. One case was complicated by bacterial infection and repeated dislocation. Conclusion: Mid-term results of total hip arthroplasty using the COREN hip system are very encouraging clinically and radiologically.
참고문헌 (24)
- Learmonth ID, "The operation of the century: total hip replacement", Lancet, 370, pp.1508~1519 (2007)[DOI]
- Charnley J, "Anchorage of the femoral head prosthesis to the shaft of the femur", J Bone Joint Surg Br, 42-B, pp.28~30 (1960)[DOI]
- Charnley J, "Arthroplasty of the hip. A new operation", Lancet, 1, pp.1129~1132 (1961)
- Jones LC, "Cement disease", Clin Orthop Relat Res, (225), pp.192~206 (1987)
- Sanfilippo JA, "Implants for total hip arthroplasty", Expert Rev Med Devices, 3, pp.769~776 (2006)[DOI]
- Ahn HY, "A case of McKee-Farrar prosthetic replacement of the hip", J Korean Orthop Assoc, 5, pp.29~34 (1970)
- Kim YM, "Clinical study of Kim's femoral stem", J Korean Orthop Assoc, 26, pp.1365~1370 (1991)
- Engh CA, "Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results", J Bone Joint Surg Br, 69, pp.45~55 (1987)
- Gruen TA, ""Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening", Clin Orthop Relat Res, (141), pp.17~27 (1979)
- DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, (121), pp.20~32 (1976)
- Joshi RP, "Osteolysis after Charnley primary low-friction arthroplasty. A comparison of two matched paired groups", J Bone Joint Surg Br, 80, pp.585~590 (1998)[DOI]
- Maloney WJ, "Endosteal erosion in association with stable uncemented femoral components", J Bone Joint Surg Am, 72, pp.1025~1034 (1990)[DOI]
- Brooker AF, "Ectopic ossification following total hip replacement. Incidence and a method of classification", J Bone Joint Surg Am, 55, pp.1629~1632 (1973)[DOI]
- Capello WN, "Ceramic-on-ceramic total hip arthroplasty: update", J Arthroplasty, 23(7 Suppl), pp.39~43 (2008)[DOI]
- 박윤수, "COREN HIP System을 이용한 무시멘트 고관절 전치환술", Hip and Pelvis, 19(4), pp.457~462 (2007), 대한고관절학회
- Lim YW, "Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation: a pilot study", Clin Orthop Relat Res, 467, pp.2251~2258 (2009)[DOI]
- 김상민, "COREN Hip System을 이용한 무시멘트 고관절 전치환술의 최소 7년 추시 결과", Hip and Pelvis, 25(3), pp.173~181 (2013), 대한고관절학회[DOI]
- 이중명, "Bencox® Hip Stem을 이용한 인공 고관절 치환술의 최소 5년 추시 결과", 대한정형외과학회지, 49(2), pp.126~132 (2014), 대한정형외과학회
- 임영욱, "대퇴골두 무혈성 괴사환자에서 시행된 인공 고관절 전치환술에서 두 무시멘트 스템간의 비교 분석 - Summit® 스템과 Bencox® 스템 -", Hip and Pelvis, 24(1), pp.25~31 (2012), 대한고관절학회
- Robinson RP, "Uncemented total hip arthroplasty using the CLS stem: a titanium alloy implant with a corundum blast finish. Results at a mean 6 years in a prospective study", J Arthroplasty, 11, pp.286~292 (1996)[DOI]
- Schramm M, "Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up", Arch Orthop Trauma Surg, 120, pp.407~412 (2000)[DOI]
- Smeekes C, "Long-term results of total hip arthroplasty with the CementLess Spotorno (CLS) system", Hip Int, 27, pp.465~471 (2017)[DOI]
- Yamasaki T, "The Cementless Spotorno stem in THA: 10 year results", Hip Int, 24, pp.98~102 (2014)[DOI]
- Yoo JJ, "Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study", J Bone Joint Surg Am, 87, pp.530~535 (2005)[DOI]