본문 바로가기
KERD
논문KCI 등재

Short-term Outcomes of Ceramic Coated Metal-on-Metal Large Head in Total Hip Replacement Arthroplasty

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: This study characterizes the short-term outcomes of ceramic coated metal-on-metal (MoM) large head total hip arthroplasty (THA) in prospectively selected patients aged 70 to 75 years. Materials and Methods: Eighteen patients (18 hips) between the ages of 70 and 75-years old with THA using ceramic-coated MoM large heads between June 2014 and December 2014 were evaluated. We prospectively selected patients younger than 70 years for bipolar hemiarthroplasty and older than 75 years for conventional THA. There were one case of osteoarthritis, 8 cases of femur neck fracture, and 9 cases of intertrochanteric fracture. All patients underwent clinical and radiological follow-up at 6 weeks, 6 and 12 months, and every year postoperatively. The mean duration of follow-up was 24.2 months (range, 18-34 months). Results: The average Harris hip score at the final follow-up was 81.0, except one case which was ultimately converted to conventional THA due to acetabular cup loosening. Radiographically, mean acetabular cup inclination was 45.8。(range, 38-56。) and anteversion was 20.1。(range, 11-25。). The average femoral head size was 48.7 mm. All stems were neutral-positioned except 1 varus-positioned stem. There was 1 case of a soft tissue infection, 3 patients complained of persistent groin pain, and no dislocations occurred. Conclusion: Ceramic coated large MOM articulation (ACCIS) have many complications: cup loosening, groin pain, which can lead to fatal outcomes in the elderly patients. Especially in patients with communicated intertrochanter fracture (AO 31-A22, 23), careful attention should be paid to the choice of surgical option.

Abstract

Purpose: This study characterizes the short-term outcomes of ceramic coated metal-on-metal (MoM) large head total hip arthroplasty (THA) in prospectively selected patients aged 70 to 75 years. Materials and Methods: Eighteen patients (18 hips) between the ages of 70 and 75-years old with THA using ceramic-coated MoM large heads between June 2014 and December 2014 were evaluated. We prospectively selected patients younger than 70 years for bipolar hemiarthroplasty and older than 75 years for conventional THA. There were one case of osteoarthritis, 8 cases of femur neck fracture, and 9 cases of intertrochanteric fracture. All patients underwent clinical and radiological follow-up at 6 weeks, 6 and 12 months, and every year postoperatively. The mean duration of follow-up was 24.2 months (range, 18-34 months). Results: The average Harris hip score at the final follow-up was 81.0, except one case which was ultimately converted to conventional THA due to acetabular cup loosening. Radiographically, mean acetabular cup inclination was 45.8。(range, 38-56。) and anteversion was 20.1。(range, 11-25。). The average femoral head size was 48.7 mm. All stems were neutral-positioned except 1 varus-positioned stem. There was 1 case of a soft tissue infection, 3 patients complained of persistent groin pain, and no dislocations occurred. Conclusion: Ceramic coated large MOM articulation (ACCIS) have many complications: cup loosening, groin pain, which can lead to fatal outcomes in the elderly patients. Especially in patients with communicated intertrochanter fracture (AO 31-A22, 23), careful attention should be paid to the choice of surgical option.

참고문헌 (29)

  1. Woo RY, "Dislocations after total hip arthroplasty", J Bone Joint Surg Am, 64, pp.1295~1306 (1982)[DOI]
  2. Turner RS, "Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management", Clin Orthop Relat Res, (301), pp.196~204 (1994)
  3. Eswaramoorthy V, "The Metasul metal-on-metal articulation in primary total hip replacement: clinical and radiological results at ten years", J Bone Joint Surg Br, 90, pp.1278~1283 (2008)
  4. Grubl A, "Long-term follow-up of metal-on-metal total hip replacement", J Orthop Res, 25, pp.841~848 (2007)[DOI]
  5. Leslie I, "Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements-An in vitro study", J Biomed Mater Res B Appl Biomater, 87, pp.163~172 (2008)
  6. Signorello LB, "A nationwide followup study of autoimmune and connective tissue disease among hip and knee implant patients", J Long Term Eff Med Implants, 12, pp.255~262 (2002)
  7. Davies AP, "Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty", J Bone Joint Surg Br, 87, pp.1439~1444 (2005)
  8. Willert HG, "Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study", J Bone Joint Surg Am, 87, pp.28~36 (2005)
  9. Huddleston JI, "Age and obesity are risk factors for adverse events after total hip arthroplasty", Clin Orthop Relat Res, 470, pp.490~496 (2012)[DOI]
  10. Whittle J, "Mortality after elective total hip arthroplasty in elderly Americans. Age, gender, and indication for surgery predict survival", Clin Orthop Relat Res, (295), pp.119~126 (1993)
  11. Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation", J Bone Joint Surg Am, 51, pp.737~755 (1969)[DOI]
  12. [URL]
  13. Widmer KH, "A simplified method to determine acetabular cup anteversion from plain radiographs", J Arthroplasty, 19, pp.387~390 (2004)[DOI]
  14. Lee SW, "Primary total hip arthroplasty using modified posterior approach through quadratus femoris flap osteotomy; comparison with conventional posterior approach", Hip Int, 26, pp.543~549 (2016)[DOI]
  15. Davis FM, "Deep vein thrombosis after total hip replacement. A comparison between spinal and general anaesthesia", J Bone Joint Surg Br, 71, pp.181~185 (1989)
  16. Sikorski JM, "The natural history and aetiology of deep vein thrombosis after total hip replacement", J Bone Joint Surg Br, 63-B, pp.171~177 (1981)[DOI]
  17. Silbersack Y, "Prevention of deep-vein thrombosis after total hip and knee replacement. Low-molecular-weight heparin in combination with intermittent pneumatic compression", J Bone Joint Surg Br, 86, pp.809~812 (2004)
  18. Banerjee S, "Large-diameter femoral heads in total hip arthroplasty: an evidence-based review", Am J Orthop (Belle Mead NJ), 43, pp.506~512 (2014)
  19. Cooper HJ, "Large diameter femoral heads: is bigger always better", Bone Joint J, 96-B(11 Supple A), pp.23~26 (2014)[DOI]
  20. Elkins JM, "Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis", Clin Orthop Relat Res, 472, pp.529~542 (2014)[DOI]
  21. Stroh DA, "Reduced dislocation rates and excellent functional outcomes with largediameter femoral heads", J Arthroplasty, 28, pp.1415~1420 (2013)[DOI]
  22. Cicek H, "Primary metal-on-metal total hip arthroplasty with large-diameter femoral heads: a clinical trial of 59 hips", Acta Orthop Belg, 76, pp.758~765 (2010)
  23. Crowninshield RD, "Biomechanics of large femoral heads: what they do and don't do", Clin Orthop Relat Res, (429), pp.102~107 (2004)
  24. Rodriguez JA, "Large diameter heads: is bigger always better", J Bone Joint Surg Br, 94(11 Suppl A), pp.52~54 (2012)[DOI]
  25. Cooper HJ, "Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty", J Bone Joint Surg Am, 94, pp.1655~1661 (2012)[DOI]
  26. Dyrkacz RM, "The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints", J Arthroplasty, 28, pp.1036~1040 (2013)[DOI]
  27. "Rev Chir Orthop Reparatrice Appar Mot", 2001, 815~819
  28. Browne JA, "Failure of larger-diameter metal-on-metal total hip arthroplasty resulting from anterior iliopsoas impingement", J Arthroplasty, 26, pp.978.e5~978.e8 (2011)
  29. Visuri T, "Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty", Clin Orthop Relat Res, (329 Suppl), pp.S280~S289 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (9건)