본문 바로가기
KERD
논문KCI 등재

Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Purpose: The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramicon-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. Materials and Methods: We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and risk factors and 25 studies in Western patients were analyzed for squeaking incidence. The data collected were: patient factors, surgical factors and implantation factors. Results: The overall incidence of hip squeaking was 2.7% in Asians and 3.1% in Westerners. This difference was not statistically significant. The only significant risk factor was an increase in the acetabular cup abduction angle. Of the factors, the cup abduction angle was the only significant risk factor for the occurrence rate of squeaking, and the occurrence rate tended to increase with increasing angle. Conclusion: The incidence of squeaking in Asians after primary ceramic-on-ceramic THA is 2.7% and is similar to that in Westerners. The increased cup abduction angle is associated with squeaking; therefore, surgeons should be careful not to implant the cup at a too steep abduction angle.

Abstract

Purpose: The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramicon-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. Materials and Methods: We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and risk factors and 25 studies in Western patients were analyzed for squeaking incidence. The data collected were: patient factors, surgical factors and implantation factors. Results: The overall incidence of hip squeaking was 2.7% in Asians and 3.1% in Westerners. This difference was not statistically significant. The only significant risk factor was an increase in the acetabular cup abduction angle. Of the factors, the cup abduction angle was the only significant risk factor for the occurrence rate of squeaking, and the occurrence rate tended to increase with increasing angle. Conclusion: The incidence of squeaking in Asians after primary ceramic-on-ceramic THA is 2.7% and is similar to that in Westerners. The increased cup abduction angle is associated with squeaking; therefore, surgeons should be careful not to implant the cup at a too steep abduction angle.

참고문헌 (43)

  1. Sedel L, "Evolution of alumina-on-alumina implants : a review", Clin Orthop Relat Res, 379, pp.48~54 (2000)
  2. Walter WL, "Squeaking hips", J Bone Joint Surg Am, 90(4), pp.102~111 (2008)
  3. Abdel MP, "Ceramic liner fractures presenting as squeaking after primary total hip arthroplasty", J Bone Joint Surg Am, 96, pp.27~31 (2014)
  4. Ecker TM, "Squeaking in total hip replacement: no cause for concern", Orthopedics, 31, pp.875~876 (2008)
  5. Walter WL, "Squeaking in ceramic-on-ceramic hips : the importance of acetabular component orientation", J Arthroplasty, 22, pp.496~503 (2007)
  6. Baek SH, "Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis", J Bone Joint Surg Am, 90, pp.1314~1320 (2008)
  7. Choi IY, "Incidence and factors associated with squeaking in alumina-on-alumina THA", Clin Orthop Relat Res, 468, pp.3234~3239 (2010)
  8. Kim YH, "Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis", Int Orthop, 34, pp.1123~1127 (2010)
  9. Cai P, "Large-diameter Delta ceramic-onceramic versus common-sized ceramic-on-polyethylene bearings in THA", Orthopedics, 35, pp.e1307~e1313 (2012)
  10. Chen WM, "No significant squeaking in total hip arthroplasty: a series of 413 hips in the Asian people", J Arthroplasty, 27, pp.1575~1579 (2012)
  11. Kuo FC, "Ceramic-on-ceramic total hip arthroplasty: incidence and risk factors of bearing surface-related noises in 125 patients", Orthopedics, 35, pp.e1581~e1585 (2012)
  12. Yoon HJ, "Alumina-onalumina THA performed in patients younger than 30 years:a 10-year minimum followup study", Clin Orthop Relat Res, 470, pp.3530~3536 (2012)
  13. Tsukada S, "Uncemented thirdgeneration ceramic-on-ceramic total hip arthroplasty using metal acetabular shell with direct taper locking liner", Arch Orthop Trauma Surg, 133, pp.861~868 (2013)
  14. Lusty PJ, "Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty", J Bone Joint Surg Am, 89, pp.2676~2683 (2007)
  15. Capello WN, "Ceramic-on-ceramic total hip arthroplasty:update", J Arthroplasty, 23(7), pp.39~43 (2008)
  16. Garcia-Cimbrelo E, "Alumina-on-alumina in THA : a multicenter prospective study", Clin Orthop Relat Res, 466, pp.309~316 (2008)
  17. Keurentjes JC, "High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings", Clin Orthop Relat Res, 466, pp.1438~1443 (2008)
  18. Restrepo C, "The noisy ceramic hip: is component malpositioning the cause?", J Arthroplasty, 23, pp.643~649 (2008)
  19. Greene JW, "Ceramic-on-ceramic total hip arthroplasty", J Arthroplasty, 24(6), pp.15~18 (2009)
  20. Jarrett CA, "The squeaking hip : a phenomenon of ceramic-on-ceramic total hip arthroplasty", J Bone Joint Surg Am, 91, pp.1344~1349 (2009)
  21. Boyer P, "Is alumina-on-alumina ceramic bearings total hip replacement the right choice in patients younger than 50 years of age? A 7-to 15-year follow-up study", Orthop Traumatol Surg Res, 96, pp.616~622 (2010)
  22. Hamilton WG, "THA with Delta ceramic on ceramic : results of a multicenter investigational device exemption trial", Clin Orthop Relat Res, 468, pp.358~366 (2010)
  23. Mai K, "Incidence of ‘squeaking’ after ceramic-onceramic total hip arthroplasty", Clin Orthop Relat Res, 468, pp.413~417 (2010)
  24. Cogan A, "Occurrence of noise in alumina-on-alumina total hip arthroplasty. A survey on 284 consecutive hips", Orthop Traumatol Surg Res, 97, pp.206~210 (2011)
  25. Hsu JE, "Ten-year followup of patients younger than 50 years with modern ceramicon-ceramic total hip arthroplasty", Semin Arthroplasty, 22, pp.229~233 (2011)
  26. Mesko JW, "Ceramic-on-ceramic hip outcome at a 5- to 10-year interval: has it lived up to its expectations?", J Arthroplasty, 26, pp.172~177 (2011)
  27. Parvizi J, "A squeaky reputation : the problem may be design-dependent", Clin Orthop Relat Res, 469, pp.1598~1605 (2011)
  28. Schroder D, "Ceramic-on-ceramic total hip arthroplasty : incidence of instability and noise", Clin Orthop Relat Res, 469, pp.437~442 (2011)
  29. Sexton SA, "The role of patient factors and implant position in squeaking of ceramic-onceramic total hip replacements", J Bone Joint Surg Br, 93, pp.439~442 (2011)
  30. Stafford GH, "Early to mid-term results of ceramic-on-ceramic total hip replacement : analysis of bearing-surface-related complications", J Bone Joint Surg Br, 93, pp.1017~1020 (2011)
  31. Steppacher SD, "Absence of osteolysis in uncemented alumina ceramic-onceramic THA in patients younger than 50 years after two to 14 years", Semin Arthroplasty, 22, pp.248~253 (2011)
  32. Chevillotte C, "Retrieval analysis of squeaking ceramic implants: are there related specific features?", Orthop Traumatol Surg Res, 98, pp.281~287 (2012)
  33. D'Antonio JA, "Ceramic bearings for total hip arthroplasty have high survivorship at 10 years", Clin Orthop Relat Res, 470, pp.373~381 (2012)
  34. Owen D, "The natural history of ceramic-on-ceramic prosthetic hip squeak and its impact on patients", Eur J Orthop Surg Traumatol, 24, pp.57~61 (2014)
  35. Kiyama T, "Can squeaking with ceramic-on-ceramic hip articulations in total hip arthroplasty be avoided?", J Arthroplasty, 28, pp.1015~1020 (2013)
  36. McDonnell SM, "The incidence of noise generation arising from the largediameter Delta Motion ceramic total hip bearing", Bone Joint J, 95-B, pp.160~165 (2013)
  37. Morlock M, "Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty", J Arthroplasty, 16, pp.1071~1074 (2001)
  38. Glaser D, "Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces", J Bone Joint Surg Am, 90(4), pp.112~120 (2008)
  39. Taylor S, "The role of stripe wear in causing acoustic emissions from alumina ceramic-onceramic bearings", J Arthroplasty, 22, pp.47~51 (2007)
  40. Yang CC, "The squeaking hip : a cause for concern-disagrees", Orthopedics, 30, pp.739~742 (2007)
  41. Chevillotte C, "The 2009 Frank Stinchfield Award : "Hip squeaking" : a biomechanical study of ceramic-on-ceramic bearing surfaces", Clin Orthop Relat Res, 468, pp.345~350 (2010)
  42. Stanat SJ, "Squeaking in third-and fourthgeneration ceramic-on-ceramic total hip arthroplasty : meta-analysis and systematic review", J Arthroplasty, 27, pp.445~453 (2012)
  43. Restrepo C, "The effect of stem design on the prevalence of squeaking following ceramicon-ceramic bearing total hip arthroplasty", J Bone Joint Surg Am, 92, pp.550~557 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (9건)