The Short-term Clinical Outcome of Total Hip Arthroplasty Using Short Metaphyseal Loading Femoral Stem
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to retrospectively evaluate the short-term clinical and radiological outcomes of total hip arthroplasty (THA) with short metaphyseal loading femoral stem. Materials and Methods: We retrospectively reviewed the records of 56 cases in 47 patients who had undergone THA with short metaphyseal loading femoral stem from April 2010 to December 2011. There were 20 males and 27 females. The mean age was 54 years (range, 26-77 years). The average follow up period was 4.6 years. Clinical results were evaluated by Harris hip scores (HHS) before the operation and at the last follow-up. Radiographic analysis was done by evaluating osteolysis, loosening, stress shielding, and alignement. Results: The mean HHS significantly improved from 45 (range, 15-58) preoperatively to 98 (range, 85-100) at the last follow-up. In radiographic analyses, there was no evidence of osteolysis or loosening around the stems and the acetabuluar components. All cases showed rounding off of the calcar, grade 1 bone resorption of the proximal femur. With regard to implant alignment, 51 femoral component (91.1%) were in neutral position, and 5 (8.9%) were in varus position. There was 1 intraoperative fracture treated by cerclage wiring and no case was revised during follow-up period. Conclusion: Although longer follow-up is needed to confirm the durability of the short metaphyseal loading femoral stem, this short stem might provide stable fixation without diaphyseal fixation and demonstrated good clinical result at mean 4.6 year short term follow-up.
Abstract
Purpose: The purpose of this study was to retrospectively evaluate the short-term clinical and radiological outcomes of total hip arthroplasty (THA) with short metaphyseal loading femoral stem. Materials and Methods: We retrospectively reviewed the records of 56 cases in 47 patients who had undergone THA with short metaphyseal loading femoral stem from April 2010 to December 2011. There were 20 males and 27 females. The mean age was 54 years (range, 26-77 years). The average follow up period was 4.6 years. Clinical results were evaluated by Harris hip scores (HHS) before the operation and at the last follow-up. Radiographic analysis was done by evaluating osteolysis, loosening, stress shielding, and alignement. Results: The mean HHS significantly improved from 45 (range, 15-58) preoperatively to 98 (range, 85-100) at the last follow-up. In radiographic analyses, there was no evidence of osteolysis or loosening around the stems and the acetabuluar components. All cases showed rounding off of the calcar, grade 1 bone resorption of the proximal femur. With regard to implant alignment, 51 femoral component (91.1%) were in neutral position, and 5 (8.9%) were in varus position. There was 1 intraoperative fracture treated by cerclage wiring and no case was revised during follow-up period. Conclusion: Although longer follow-up is needed to confirm the durability of the short metaphyseal loading femoral stem, this short stem might provide stable fixation without diaphyseal fixation and demonstrated good clinical result at mean 4.6 year short term follow-up.
참고문헌 (30)
- Kurtz S, "Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002", J Bone Joint Surg Am, 87, pp.1487~1497 (2005)
- Ulrich SD, "Total hip arthroplasties : what are the reasons for revision?", Int Orthop, 32, pp.597~604 (2008)
- Morrey BF, "Short-stemmed uncemented femoral component for primary hip arthroplasty", Clin Orthop Relat Res, 249, pp.169~175 (1989)
- Tóth K, "Early experience with the Depuy Proxima short stem in total hip arthroplasty", Acta Orthop Belg, 76, pp.613~618 (2010)
- Judet J, "The use of an artificial femoral head for arthroplasty of the hip joint", J Bone Joint Surg Br, 32-B, pp.166~173 (1950)
- Fink B, "Midterm results of"thrust plate"prosthesis", J Arthroplasty, 22, pp.703~710 (2007)
- Fottner A, "Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions", Clin Biomech(Bristol, Avon), 24, pp.429~434 (2009)
- Morrey BF, "A conservative femoral replacement for total hip arthroplasty. A prospective study", J Bone Joint Surg Br, 82, pp.952~958 (2000)
- Learmonth ID, "Conservative stems in total hip replacement", Hip Int, 19, pp.195~200 (2009)
- Kim YH, "A prospective shortterm outcome study of a short metaphyseal fitting total hip arthroplasty", J Arthroplasty, 27, pp.88~94 (2012)
- Santori N, "Proximal load transfer with a stemless uncemented femoral implant", J Orthop Traumatol, 7, pp.154~160 (2006)
- Harris WH, "Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation", J Bone Joint Surg Am, 51, pp.737~755 (1969)
- DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, 121, pp.20~32 (1976)
- Dorr LD, "Anatomic Porous Replacement hip arthroplasty : first 100 consecutive cases", Semin Arthroplasty, 1, pp.77~86 (1990)
- Martell JM, "Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement", J Bone Joint Surg Am, 75, pp.554~571 (1993)
- Tanzer M, "The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement", J Bone Joint Surg Am, 74, pp.404~410 (1992)
- Dorr LD, "Structural and cellular assessment of bone quality of proximal femur", Bone, 14, pp.231~242 (1993)
- Ghera S, "The DePuy Proxima hip: a short stem for total hip arthroplasty. Early experience and technical considerations", Hip Int, 19, pp.215~220 (2009)
- Gruen TA, ""Modes of failure"of cemented stem-type femoral components : a radiographic analysis of loosening", Clin Orthop Relat Res, 141, pp.17~27 (1979)
- Kim YH, "Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating", J Bone Joint Surg Am, 85-A, pp.1682~1688 (2003)
- Engh CA Jr, "Longterm results using the anatomic medullary locking hip prosthesis", Clin Orthop Relat Res, 393, pp.137~146 (2001)
- Brooker AF, "Ectopic ossification following total hip replacement. Incidence and a method of classification", J Bone Joint Surg Am, 55, pp.1629~1632 (1973)
- McMinn DJ, "Avascular necrosis in the young patient : a trilogy of arthroplasty options", Orthopedics, 28, pp.945~947 (2005)
- Thomas W, "ESKA(CUT)endoprosthesis", Orthopade, 33, pp.1243~1248 (2004)
- Walker PS, "Stability and bone preservation in custom designed revision hip stems", Clin Orthop Relat Res, 373, pp.164~173 (2000)
- 유주형, "Versys Fiber Metal Midcoat 대퇴스템을 이용한 무시멘트 인공 고관절 전치환술 후 최소 3년 추시 결과", Hip and Pelvis, 22(1), pp.45~51 (2010), 대한고관절학회
- Kim YH, "Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age", J Bone Joint Surg Am, 85-A, pp.109~114 (2003)
- Westphal FM, "Migration and cyclic motion of a new shortstemmed hip prosthesis--a biomechanical in vitro study", Clin Biomech(Bristol, Avon), 21, pp.834~840 (2006)
- Santori FS, "Ultra-short stems with proximal load transfer: clinical and radiographic results at five-year follow-up", Hip Int, 16(Suppl 3), pp.31~39 (2006)
- Kim YH, "Early migration of uncemented porous coated anatomic femoral component related to aseptic loosening", Clin Orthop Relat Res, 295, pp.146~155 (1993)
