A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 µm to 91 ± 63 µm)while the worst values were obtained with Trios3 (mean from 42 ± 23 µm to 174 ± 77 µm). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

Abstract

PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 µm to 91 ± 63 µm)while the worst values were obtained with Trios3 (mean from 42 ± 23 µm to 174 ± 77 µm). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

참고문헌 (40)

  1. Jemt T, "Accuracy of implant-supported prostheses in the edentulous jaw : analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a threedimensional photogrammetric technique", Clin Oral Implants Res, 6, pp.172~180 (1995)
  2. Kan JY, "Clinical methods for evaluating implant framework fit", J Prosthet Dent, 81, pp.7~13 (1999)
  3. Christensen GJ, "Marginal fit of gold inlay castings", J Prosthet Dent, 16, pp.297~305 (1966)
  4. Dedmon HW, "Disparity in expert opinions on size of acceptable margin openings", Oper Dent, 7, pp.97~101 (1982)
  5. Jemt T, "Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws : a study of treatment from the time of prosthesis placement to the first annual checkup", Int J Oral Maxillofac Implants, 6, pp.270~276 (1991)
  6. Andriessen FS, "Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles : a pilot study", J Prosthet Dent, 111, pp.186~194 (2014)
  7. Heckmann SM, "Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures", Clin Oral Implants Res, 15, pp.466~473 (2004)
  8. Vandeweghe S, "Accuracy of digital impressions of multiple dental implants : an in vitro study", Clin Oral Implants Res, 28, pp.648~653 (2017)
  9. Kim Y, "Occlusal considerations in implant therapy : clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
  10. Bacchi A, "Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application : 3-D finite element analysis", Acta Odontol Scand, 71, pp.1243~1249 (2013)
  11. Patzelt SB, "Accuracy of full-arch scans using intraoral scanners", Clin Oral Investig, 18, pp.1687~1694 (2014)
  12. Christensen GJ, "Will digital impressions eliminate the current problems with conventional impressions?", J Am Dent Assoc, 139, pp.761~763 (2008)
  13. Christensen GJ, "Impressions are changing: deciding on conventional, digital or digital plus in-office milling", J Am Dent Assoc, 140, pp.1301~1304 (2009)
  14. Richert R, "Intraoral scanner technologies : A review to make a successful impression", J Healthc Eng, 2017, pp.8427595~ (2017)
  15. Ahrberg D, "Evaluation of fit and efficiency of CAD", CAM fabricated all-ceramic restorations based on direct and indirect digitalization : a doubleblinded, randomized clinical trial, 2016, pp.20, 291~300
  16. Gjelvold B, "Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial", J Prosthodont, 25, pp.282~287 (2016)
  17. Lee SJ, "Digital vs. conventional implant impressions:efficiency outcomes", Clin Oral Implants Res, 24, pp.111~115 (2013)
  18. Patzelt SB, "The time efficiency of intraoral scanners : an in vitro comparative study", J Am Dent Assoc, 145, pp.542~551 (2014)
  19. Gallardo YR, "Patient outcomes and procedure working time for digital versus conventional impressions: A systematic review", J Prosthet Dent, 119, pp.214~219 (2018)
  20. Burhardt L, "Treatment comfort, time perception, and preference for conventional and digital impression techniques: A comparative study in young patients", Am J Orthod Dentofacial Orthop, 150, pp.261~267 (2016)
  21. Hack GD, "Evaluation of the accuracy of six intra-oral scanning devices : An in-vitro investigation", American Dent Assoc, 10, pp.1~5 (2015)
  22. Omar Ali A, "Accuracy of digital impressions achieved from five different digital impression system", J Prosthodontics, 5, pp.2~6 (2015)
  23. van der Meer WJ, "Application of intra-oral dental scanners in the digital workflow of implantology", PLoS One, 7, pp.e43312~ (2012)
  24. Fukazawa S, "Investigation of accuracy and reproducibility of abutment position by intraoral scanners", J Prosthodont Res, 61, pp.450~459 (2017)
  25. Güth JF, "Accuracy of five intraoral scanners compared to indirect digitalization", Clin Oral Investig, 21, pp.1445~1455 (2017)
  26. Imburgia M, "Accuracy of four intraoral scanners in oral implantology : a comparative in vitro study", BMC Oral Health, 17, pp.92~ (2017)
  27. Patzelt SB, "Accuracy of computeraided design", computer-aided manufacturing-generated dental casts based on intraoral scanner data, 2014, pp.145, 1133~1140
  28. Ender A, "Accuracy of complete-arch dental impressions : a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)
  29. Ender A, "In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions", Quintessence Int, 46, pp.9~17 (2015)
  30. Güth JF, "A new method for the evaluation of the accuracy of full-arch digital impressions in vitro", Clin Oral Investig, 20, pp.1487~1494 (2016)
  31. Syrek A, "Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling", J Dent, 38, pp.553~559 (2010)
  32. Zarauz C, "Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions", Clin Oral Investig, 20, pp.799~806 (2016)
  33. Ender A, "In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions", J Prosthet Dent, 115, pp.313~320 (2016)
  34. Ender A, "In vivo precision of conventional and digital methods for obtaining quadrant dental impressions", Clin Oral Investig, 20, pp.1495~1504 (2016)
  35. Zimmermann M, "Precision of guided scanning procedures for full-arch digital impressions in vivo", J Orofac Orthop, 78, pp.466~471 (2017)
  36. Zhang F, "Validity of intraoral scans compared with plaster models : An in-vivo comparison of dental measurements and 3D surface analysis", PLoS One, 11, pp.e0157713~ (2016)
  37. Kuhr F, "A new method for assessing the accuracy of full arch impressions in patients", J Dent, 55, pp.68~74 (2016)
  38. Nedelcu R, "Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method", J Dent, 69, pp.110~118 (2018)
  39. Shim JS, "Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD", CAM system, 2015, pp.23, 515~522
  40. Mangano F, "Intraoral scanners in dentistry : a review of the current literature", BMC Oral Health, 17, pp.149~ (2017)

관련 논문AI추천

이 간행물의 다른 논문 (5건)