본문 바로가기
KERD
논문KCI 등재

In-vitro development of a temporal abutment screw to protect osseointegration in immediately loaded implants

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30º in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov–Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student›s t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.

Abstract

PURPOSE. In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30º in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov–Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student›s t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.

참고문헌 (17)

  1. Esposito M, "Interventions for replacing missing teeth: different times for loading dental implants", Cochrane Database Syst Rev, 3, pp.CD003878~ (2013)
  2. Szmukler-Moncler S, "Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature", J Biomed Mater Res, 43, pp.192~203 (1998)
  3. Misch CE, "Rationale for the application of immediate load in implant dentistry: Part I", Implant Dent, 13, pp.207~217 (2004)
  4. Brunski JB, "Avoid pitfalls of overloading and micromotion of intraosseous implants", Dent Implantol Update, 4, pp.77~81 (1993)
  5. Kawahara H, "Osseointegration under immediate loading:biomechanical stress-strain and bone formation-resorption", Implant Dent, 12, pp.61~68 (2003)
  6. Chang PK, "Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study", Int J Oral Maxillofac Implants, 27, pp.e96~e101 (2012)
  7. Javed F, "The role of primary stability for successful immediate loading of dental implants. A literature review", J Dent, 38, pp.612~620 (2010)
  8. Trisi P, "Implant micromotion is related to peak insertion torque and bone density", Clin Oral Implants Res, 20, pp.467~471 (2009)
  9. Wazen RM, "Micromotion-induced strain fields influence early stages of repair at bone-implant interfaces", Acta Biomater, 9, pp.6663~6674 (2013)
  10. Winter W, "Effect of model parameters on finite element analysis of micromotions in implant dentistry", J Oral Implantol, 39, pp.23~29 (2013)
  11. Mericske-Stern R, "Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants", Int J Oral Maxillofac Implants, 10, pp.345~353 (1995)
  12. Waltimo A, "Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients", Acta Odontol Scand, 53, pp.254~258 (1995)
  13. Flanagan D, "Force and movement of non-osseointegrated implants: an in vitro study", J Oral Implantol, 35, pp.270~276 (2009)
  14. Fazel A, "Effect of macro-design of immediately loaded implants on micromotion and stress distribution in surrounding bone using finite element analysis", Implant Dent, 18, pp.345~352 (2009)
  15. Freitas AC Jr, "The effect of implant design on insertion torque and immediate micromotion", Clin Oral Implants Res, 23, pp.113~118 (2012)
  16. Engelke W, "In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy", Implant Dent, 13, pp.88~94 (2004)
  17. Steinebrunner L, "Implantabutment interface design affects fatigue and fracture strength of implants", Clin Oral Implants Res, 19, pp.1276~1284 (2008)

관련 논문AI추천

Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading이주희, 차현석대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제6호Influence of the implant abutment types and the dynamic loading on initial screw loosening김은숙, 신수연대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제1호Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants배지명, 이진한, 조혜원, Hnd Hadi Mohammed대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제1호Mechanical analysis of conventional and small diameter conical implant abutmentsAdriana Cla′udia Lapria Faria, Izabela Cristina Maurl′cio Moris, Maria da Gloria Chiarello de Mattos, Renata Cristina Silveira Rodrigues, Ricardo Faria Ribeiro대한치과보철학회 · The Journal of Advanced of Prosthodontics2012 · 제4권 제3호Effect of cyclic loading and retightening on reverse torque value in external and internal implants박찬진, 조리라, 조웅래, 허윤혁대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호Influence of the implant-abutment connection design and diameter on the screw joint stability신현모, 윤미정, 전영찬, 정창모, 허중보, Brian Myung Chang대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제2호

이 간행물의 다른 논문 (13건)