Influence of the implant abutment types and the dynamic loading on initial screw loosening
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.
Abstract
PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.
참고문헌 (38)
- Schmitt A, "The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement", Int J Prosthodont, 6, pp.197~202 (1993)
- Wannfors K, "A prospective clinical evaluation of different single-tooth restoration designs on osseointegrated implants. A 3-year follow-up of Brånemark implants", Clin Oral Implants Res, 10, pp.453~458 (1999)
- Laney WR, "Osseointegrated implants for single-tooth replacement: progress report from a multicenter prospective study after 3 years", Int J Oral Maxillofac Implants, 9, pp.49~54 (1994)
- Jemt T, "A 3-year follow-up study on single implant treatment", J Dent, 21, pp.203~208 (1993)
- Kang YM, "A study on the abutment screw loosening of dental implants", J Korean Acad Prosthodont, 34, pp.1~14 (1996)
- Lazzara R, "Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period", Clin Oral Implants Res, 7, pp.73~83 (1996)
- Jörnéus L, "Loads and designs of screw joints for single crowns supported by osseointegrated implants", Int J Oral Maxillofac Implants, 7, pp.353~359 (1992)
- Burguete RL, "Tightening characteristics for screwed joints in osseointegrated dental implants", Prosthet Dent, 71, pp.592~599 (1994)
- Haack JE, "Elongation and preload stress in dental implant abutment screws", Int J Oral Maxillofac Implants, 10, pp.529~536 (1995)
- Martin WC, "Implant abutment screw rotations and preloads for four different screw materials and surfaces", J Prosthet Dent, 86, pp.2432~ (2001)
- Cibirka RM, "Examination of the implant-abutment interface after fatigue testing", J Prosthet Dent, 85, pp.268~275 (2001)
- Sawase T, "Chemical and topographical surface analysis of five different implant abutments", Clin Oral Implants Res, 11, pp.44~50 (2000)
- Heydecke G, "Evolution and use of aluminum oxide single-tooth implant abutments: a short review and presentation of two cases", Int J Prosthodont, 15, pp.488~493 (2002)
- Wood MR, "A review of selected dental literature on evidence-based treatment planning for dental implants: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics", J Prosthet Dent, 92, pp.447~462 (2004)
- Priest G, "Virtual-designed and computer-milled implant abutments", J Oral Maxillofac Surg, 63, pp.22~32 (2005)
- Ortorp A, "Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible", Int J Prosthodont, 16, pp.194~200 (2003)
- Al-Fadda SA, "A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks", Int J Prosthodont, 20, pp.125~131 (2007)
- 오병두, "임플란트 지대주 종류와 동적하중이 고정체와 지대주의 미세간극에 미치는 영향", 구강회복응용과학지, 26(4), pp.389~403 (2010), 대한턱관절교합학회
- Kapos T, "Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry", Int J Oral Maxillofac Implants, 24, pp.110~117 (2009)
- Schwarz MS, "Mechanical complications of dental implants", Clin Oral Implants Res, 11, pp.156~158 (2000)
- Binon PP, "Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs", Int J Prosthodont, 8, pp.162~178 (1995)
- Merz BR, "Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection", Int J Oral Maxillofac Implants, 15, pp.519~526 (2000)
- Norton MR, "An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design", Clin Oral Implants Res, 8, pp.290~298 (1997)
- Weiss EI, "Effect of repeated closures on opening torque values in seven abutment-implant systems", J Prosthet Dent, 84, pp.194~199 (2000)
- Norton MR, "Assessment of cold welding properties of the internal conical interface of two commercially available implant systems", J Prosthet Dent, 81, pp.159~166 (1999)
- Balfour A, "Comparative study of antirotational single tooth abutments", J Prosthet Dent, 73, pp.36~43 (1995)
- Theoharidou A, "Abutment screw loosening in single-implant restorations: a systematic review", Int J Oral Maxillofac Implants, 23, pp.681~690 (2008)
- Jaarda MJ, "Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws", Implant Dent, 3, pp.17~21 (1994)
- Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses", J Oral Implantol, 28, pp.67~73 (2002)
- Tan KB, "Implant-abutment screw joint preload of 7 hex-top abutment systems", Int J Oral Maxillofac Implants, 16, pp.367~377 (2001)
- Binon PP, "The effect of eliminating implant", abutment rotational misfit on screw joint stability, 1996, pp.9, 511~519
- Lee J, "Wave analysis of implant screw loosening using an air cylindrical cyclic loading device", J Prosthet Dent, 88, pp.402~408 (2002)
- Vigolo P, "Evaluation of gold-machined UCLA-type abutments and CAD", CAM titanium abutments with hexagonal external connection and with internal connection, 2008, pp.23, 247~252
- Abduo J, "Fit of screw-retained fixed implant frameworks fabricated by different methods: a systematic review", Int J Prosthodont, 24, pp.207~220 (2011)
- Bates JF, "Masticatory function - a review of the literature. III. Masticatory performance and efficiency", J Oral Rehabil, 3, pp.57~67 (1976)
- Mohl ND, "A textbook of occlusion", pp.148~152 (1998), Quintessence pub
- Gibbs CH, "Limits of human bite strength", J Prosthet Dent, 56, pp.226~229 (1986)
- 배병룡, "임플랜트 지대주 종류가 나사풀림력과 연결부의 안정성에 미치는 영향", 구강회복응용과학지, 26(2), pp.97~109 (2010), 대한턱관절교합학회
