Evaluation and comparison of the marginal adaptation of two different substructure materials
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and twoway variance analysis was used for more than two data sets. Pearson’s correlation analysis was also performed to assess relationships between variables. RESULTS. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, 24.47 ± 5.82 μm before and 35.11 ± 6.52 μm after cementation; in the laser-sintered Co-Cr structure, it was, on average, 60.45 ± 8.87 μm before and 69.33 ± 9.03 μm after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.
Abstract
PURPOSE. In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and twoway variance analysis was used for more than two data sets. Pearson’s correlation analysis was also performed to assess relationships between variables. RESULTS. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, 24.47 ± 5.82 μm before and 35.11 ± 6.52 μm after cementation; in the laser-sintered Co-Cr structure, it was, on average, 60.45 ± 8.87 μm before and 69.33 ± 9.03 μm after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.
참고문헌 (41)
- Shillingburg HT, "Fundamentals of fixed prosthodontics", pp.290~ (1997), Quintessence Pub. Co
- Jacobs MS, "An investigation of dental luting cement solubility as a function of the marginal gap", J Prosthet Dent, 65, pp.436~442 (1991)
- 양재호, "Marginal fit of the auro galvano crown system made using the electroforming technique", 대한치과보철학회지, 42(6), pp.679~684 (2004), 대한치과보철학회
- Rudolf R, "Dental materials - Challenge and usage of the latest inventions", Metalurgija - J Metal, 14, pp.135~142 (2008)
- "EÜ Dişhek Fak Derg", 2008, 81~92
- Zhang XH, "Clinical follow-up of ceramic bridges with auro-galvanoforming primary coping and Ni-Cr pontic for restoration of dentition defects", Chin Med J, 122, pp.3007~3010 (2009)
- Setcos JC, "The safety of nickel containing dental alloys", Dent Mater, 22, pp.1163~1168 (2006)
- Wataha JC, "Brushing-induced surface roughness of nickel-, palladium-, and gold-based dental casting alloys", J Prosthet Dent, 99, pp.455~460 (2008)
- Wataha JC, "Biocompatibility of dental casting alloys: a review", J Prosthet Dent, 83, pp.223~234 (2000)
- Rubo JH, "The effect of tin-electroplating on the bond of four dental alloys to resin cement: an in vitro study", J Prosthet Dent, 80, pp.27~31 (1998)
- Covington JS, "Quantization of nickel and beryllium leakage from base metal casting alloys", J Prosthet Dent, 54, pp.127~136 (1985)
- O’brien WJ, "Dental materials and their selection", pp.309~ (2002), Quintessence Pub. Co. Inc
- Naumann M, "Galvanovs. metal-ceramic crowns: up to 5-year results of a randomised split-mouth study", Clin Oral Investig, 15, pp.657~660 (2011)
- Eroglu Z, "Investigation of fracture strength of galvano ceramic, metal ceramic three unit bridges", J Health Sci, 20, pp.92~98 (2011)
- Vence BS, "Electroforming technology for galvanoceramic restorations", J Prosthet Dent, 77, pp.444~449 (1997)
- Weishaupt P, "Clinical and inflammatory effects of galvano-ceramic and metal-ceramic crowns on periodontal tissues", J Oral Rehabil, 34, pp.941~947 (2007)
- Buso L, "Marginal fit of electroformed copings before and after the coction of the porcelain", Braz J Oral Sci, 3, pp.409~413 (2004)
- Stewart RM, "Electroforming as an alternative to full ceramic restorations and cast substructures", Trends Tech Contemp Dent Lab, 11, pp.42~47 (1994)
- Vrijhoef MM, "Electroforming as an alternative to casting: a preliminary report", Restorative Dent, 1, pp.143~ (1985)
- Rogers OW, "The electroformed gold matrix inlay technique", Aust Dent J, 15, pp.316~323 (1970)
- Rogers OW, "The dental application of electroformed pure gold. III. An investigation into an alternative ceramic bonding system for base metal alloys", Aust Dent J, 25, pp.205~208 (1980)
- Hauk V, "Structural and residual stress analysis by nondestructive methods: Evaluation-Application-Assessment", pp.53~72 (1997), Elsevier
- Moneret-Vautrin DA, "Allergy to nickel in dental alloys", Eur Ann Allergy Clin Immunol, 36, pp.311~312 (2004)
- Senkutvan RS, "Evaluation of nickel ion release from various orthodontic arch wires: An in vitro study", J Int Soc Prev Community Dent, 4, pp.12~16 (2014)
- Wataha JC, "Casting alloys", Dent Clin North Am, 48, pp.499~512 (2004)
- Kokubo Y, "Clinical evaluation of porcelain fused to electroformed gold copings: Preliminary results after 30-43 months", Prosthodont Res Pract, 6, pp.50~56 (2007)
- Sönmez A, "In-vitro evaluation of marginal adaptation and porcelain bonding of galvano crowns and comparison with Ni-Cr alloys", 박사, pp.2008
- Oyagüe RC, "Vertical discrepancy and microleakage of lasersintered and vacuum-cast implant-supported structures luted with different cement types", J Dent, 40, pp.123~130 (2012)
- Örtorp A, "The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study", Dent Mater, 27, pp.356~363 (2011)
- Andersson M, "Accuracy of machine milling and spark erosion with a CAD", CAM system, 1996, pp.76, 187~193
- Bindl A, "Fit of all-ceramic posterior fixed partial denture frameworks in vitro", Int J Periodontics Restorative Dent, 27, pp.567~575 (2007)
- Att W, "Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses", J Prosthet Dent, 101, pp.239~247 (2009)
- Albert FE, "Marginal Adaptation and Microleakace of Procem Allceram Copings- an in vitro study", 박사, pp.2001
- Wu JC, "A comparison of the marginal adaptation of cathode-arc vapor-deposited titanium and cast base metal copings", J Prosthet Dent, 105, pp.403~409 (2011)
- Buso L, "Evaluation of the marginal fit of electroformed copings in function of the cervical preparation", Cienc Odontol Bras, 7, pp.14~20 (2004)
- Polansky R, "Comparision of the marginal fit of different all-ceramic and metal-ceramic crown system: an in vitro study", J Stomat Occl Med, 3, pp.106~110 (2010)
- Yeo IS, "In vitro marginal fit of three all-ceramic crown systems", J Prosthet Dent, 90, pp.459~464 (2003)
- Gonzalo E, "A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation", J Prosthet Dent, 102, pp.378~384 (2009)
- Cho L, "Effect of finish line variants on marginal accuracy and fracture strength of ceramic optimized polymer", fiber-reinforced composite crowns, 2004, pp.91, 554~560
- Quintas AF, "Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation", J Prosthet Dent, 92, pp.250~257 (2004)
- Ehrenberg D, "Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: a pilot study", J Prosthet Dent, 95, pp.230~236 (2006)
