본문 바로가기
KERD
논문KCI 등재

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 µm (group_cer_npl for specimens of Ceramill NPL) and 43 µm (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 µm and 28 µm without the oxide layer. The internal gap varied between 33 µm (group_ti_nem for test samples of Tizian NEM) and 75 µm (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 µm and 76 µm without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

Abstract

PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 µm (group_cer_npl for specimens of Ceramill NPL) and 43 µm (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 µm and 28 µm without the oxide layer. The internal gap varied between 33 µm (group_ti_nem for test samples of Tizian NEM) and 75 µm (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 µm and 76 µm without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

참고문헌 (42)

  1. Hunter AJ, "Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations", J Prosthet Dent, 64, pp.636~642 (1990)
  2. Fusayama T, "Factors and technique of precision casting part II", J Prosthet Dent, 9, pp.486~497 (1959)
  3. Quante K, "Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology", Dent Mater, 24, pp.1311~1315 (2008)
  4. Beuer F, "Marginal and internal fits of fixed dental prostheses zirconia retainers", Dent Mater, 25, pp.94~102 (2009)
  5. Quintas AF, "Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation", J Prosthet Dent, 92, pp.250~257 (2004)
  6. Rai R, "Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques", Indian J Dent Res, 28, pp.291~297 (2017)
  7. Rekow D, "Near-surface damage--a persistent problem in crowns obtained by computer-aided design and manufacturing", Proc Inst Mech Eng H, 219, pp.233~243 (2005)
  8. Ortengren U, "Water sorption and flexural properties of a composite resin cement", Int J Prosthodont, 13, pp.141~147 (2000)
  9. Silva NR, "Effect of water storage time and composite cement thickness on fatigue of a glass-ceramic trilayer system", J Biomed Mater Res B Appl Biomater, 84, pp.117~123 (2008)
  10. Oysaed H, "Composites for use in posterior teeth : mechanical properties tested under dry and wet conditions", J Biomed Mater Res, 20, pp.261~271 (1986)
  11. Siadat H, "Scanning electron microscope evaluation of vertical and horizontal discrepancy in cast copings for single-tooth implant-supported prostheses", Implant Dent, 17, pp.299~308 (2008)
  12. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  13. Iglesias A, "Accuracy of wax, autopolymerized, and light-polymerized resin pattern materials", J Prosthodont, 5, pp.201~205 (1996)
  14. Kohorst P, "Different CAD", CAM-processing routes for zirconia restorations : influence on fitting accuracy, 2011, pp.15, 527~536
  15. Tjan AH, "Marginal accuracy of complete crowns made from alternative casting alloys", J Prosthet Dent, 66, pp.157~164 (1991)
  16. Wassell RW, "Crowns and extra-coronal restorations : materials selection", Br Dent J, 192, pp.199~202 (2002)
  17. Nesse H, "Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques", J Prosthet Dent, 114, pp.686~692 (2015)
  18. Mai HN, "Comparative study of the fit accuracy of full-arch bar frameworks fabricated with different presintered cobalt-chromium alloys", Biomed Res Int, 2018, pp.1962514~ (2018)
  19. Vojdani M, "A Comparison of the marginal and internal fit of cobaltchromium copings fabricated by two different CAD", CAM systems(CAD, Ceramill Sintron), pp.J Dent(Shiraz), 2016[DOI]
  20. Kane LM, "Marginal and internal adaptation of milled cobalt-chromium copings", J Prosthet Dent, 114, pp.680~685 (2015)
  21. Tamac E, "Clinical marginal and internal adaptation of CAD", CAM milling, laser sintering, and cast metal ceramic crowns, 2014, pp.112, 909~913
  22. Ucar Y, "Internal fit evaluation of crowns prepared using a new dental crown fabrication technique : laser-sintered Co-Cr crowns", J Prosthet Dent, 102, pp.253~259 (2009)
  23. Holmes JR, "Marginal fit of castable ceramic crowns", J Prosthet Dent, 67, pp.594~599 (1992)
  24. Kohorst P, "Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design", computer-aided manufacturing systems, 2009, pp.117, 319~325
  25. Mously HA, "Marginal and internal adaptation of ceramic crown restorations fabricated with CAD", CAM technology and the heatpress technique, 2014, pp.112, 249~256
  26. Nawafleh NA, "Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs : a literature review", J Prosthodont, 22, pp.419~428 (2013)
  27. Boening KW, "Clinical fit of Procera AllCeram crowns", J Prosthet Dent, 84, pp.419~424 (2000)
  28. Praça L, "Accuracy of single crowns fabricated from ultrasound digital impressions", Dent Mater, 34, pp.e280~e288 (2018)
  29. Al Hamad KQ, "Comparison of the fit of lithium disilicate crowns made from conventional, digital, or conventional", digital techniques, 2019, pp.28, e580~e586
  30. Harris IR, "A comparison of the fit of sparkeroded titanium copings and cast gold alloy copings", Int J Prosthodont, 7, pp.348~355 (1994)
  31. Zimmermann M, "Digital evaluation of the fit of zirconia-reinforced lithium silicate crowns with a new three-dimensional approach", Quintessence Int, 49, pp.9~15 (2018)
  32. Abduo J, "Fit of zirconia fixed partial denture : a systematic review", J Oral Rehabil, 37, pp.866~876 (2010)
  33. Laurent M, "Clinical evaluation of the marginal fit of cast crowns-validation of the silicone replica method", J Oral Rehabil, 35, pp.116~122 (2008)
  34. Rahme HY, "In vitro evaluation of the"replica technique"in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
  35. Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
  36. Hung SH, "Marginal fit of porcelain-fused-to-metal and two types of ceramic crown", J Prosthet Dent, 63, pp.26~31 (1990)
  37. Goldman M, "Microleakage-full crowns and the dental pulp", J Endod, 18, pp.473~475 (1992)
  38. Bhaskaran E, "Comparative evaluation of marginal and internal gap of Co-Cr copings fabricated from conventional wax pattern, 3D printed resin pattern and DMLS tech: An in vitro study", J Indian Prosthodont Soc, 13, pp.189~195 (2013)
  39. Vojdani M, "Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD", CAM and conventional wax up techniques, 2013, pp.14, 118~129
  40. Striezel R, "The name of publisher is double, so that we can delete one" (2007), Verlag Neuer Merkur
  41. Rosel M, "Investigations of the retention of cast crowns as a function of the cement gap width and type of cement" (2004), Halle-Wittenberg
  42. Gonzalo E, "A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation", J Prosthet Dent, 102, pp.378~384 (2009)

이 간행물의 다른 논문 (7건)