Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

Abstract

PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

참고문헌 (50)

  1. Hebel KS, "Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry", J Prosthet Dent, 77, pp.28~35 (1997)
  2. Chee W, "Cemented versus screw-retained implant prostheses: which is better?", Int J Oral Maxillofac Implants, 14, pp.137~141 (1999)
  3. Taylor TD, "Prosthodontic considerations", Clin Oral Implants Res, 11, pp.101~107 (2000)
  4. Taylor TD, "Implant prosthodontics: current perspective and future directions", Int J Oral Maxillofac Implants, 15, pp.66~75 (2000)
  5. Taylor TD, "Twenty years of progress in implant prosthodontics", J Prosthet Dent, 88, pp.89~95 (2002)
  6. Michalakis KX, "Cement-retained versus screw-retained implant restorations: a critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
  7. Heckmann SM, "Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures", Clin Oral Implants Res, 15, pp.466~473 (2004)
  8. Vigolo P, "Cemented versus screw-retained implant-supported single-tooth crowns: a 4-year prospective clinical study", Int J Oral Maxillofac Implants, 19, pp.260~265 (2004)
  9. Wood MR, "A review of selected dental literature on evidence-based treatment planning for dental implants: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics", J Prosthet Dent, 92, pp.447~462 (2004)
  10. Taylor PA, "Incorporating retrievability in fixed implant-supported prostheses by transverse fixation in the ITI abutment system", J Can Dent Assoc, 70, pp.459~463 (2004)
  11. Clausen GF, "The lingual locking screw for implant-retained restorations-aesthetics and retrievability", Aust Prosthodont J, 9, pp.17~20 (1995)
  12. McGlumphy EA, "Implant screw mechanics", Dent Clin North Am, 42, pp.71~89 (1998)
  13. Keith SE, "Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments", Int J Oral Maxillofac Implants, 14, pp.369~378 (1999)
  14. Guichet DL, "Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs", Int J Oral Maxillofac Implants, 15, pp.239~246 (2000)
  15. Preiskel HW, "Telescopic prostheses for implants", Int J Oral Maxillofac Implants, 13, pp.352~357 (1998)
  16. Lindström H, "The implant-supported telescopic prosthesis: a biomechanical analysis", Int J Oral Maxillofac Implants, 16, pp.34~42 (2001)
  17. Preiskel HW, "Cement- and screw-retained implantsupported prostheses: up to 10 years of follow-up of a new design", Int J Oral Maxillofac Implants, 19, pp.87~91 (2004)
  18. Kim SG, "In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design", Int J Oral Maxillofac Implants, 24, pp.1061~1067 (2009)
  19. Karl M, "In vitro study on passive fit in implant-supported 5-unit fixed partial dentures", Int J Oral Maxillofac Implants, 19, pp.30~37 (2004)
  20. Guichet DL, "Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs", Int J Oral Maxillofac Implants, 15, pp.239~246 (2000)
  21. Papavasiliou G, "Finite element analysis of ceramic abutment-restoration combinations for osseointegrated implants", Int J Prosthodont, 9, pp.254~260 (1996)
  22. Cantwell A, "Preload loss in gold prosthesis-retaining screws as a function of time", Int J Oral Maxillofac Implants, 19, pp.124~132 (2004)
  23. Jörnéus L, "Loads and designs of screw joints for single crowns supported by osseointegrated implants", Int J Oral Maxillofac Implants, 7, pp.353~359 (1992)
  24. Haack JE, "Elongation and preload stress in dental implant abutment screws", Int J Oral Maxillofac Implants, 10, pp.529~536 (1995)
  25. Bickford JH, "An Introduction to the Design and Behaviour of Bolted Joints", pp.175~212 (1995), Marcel Dekker
  26. Tzenakis GK, "The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws", J Prosthet Dent, 88, pp.183~191 (2002)
  27. Binon PP, "The effect of eliminating implant", abutment rotational misfit on screw joint stability, 1996, pp.9, 511~519
  28. Byrne D, "The fit of cast and premachined implant abutments", J Prosthet Dent, 80, pp.184~192 (1998)
  29. Rangert B, "Forces and moments on Branemark implants", Int J Oral Maxillofac Implants, 4, pp.241~247 (1989)
  30. Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses", J Oral Implantol, 28, pp.67~73 (2002)
  31. Khraisat A, "Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system", J Prosthet Dent, 91, pp.326~334 (2004)
  32. Merz BR, "Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection", Int J Oral Maxillofac Implants, 15, pp.519~526 (2000)
  33. Kitamura E, "Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis", Clin Oral Implants Res, 15, pp.401~412 (2004)
  34. Graf H, "Bruxism", Dent Clin North Am, 13, pp.659~665 (1969)
  35. Ongthiemsak C, "The effect of compressive cyclic loading on retention of a temporary cement used with implants", J Oral Implantol, 31, pp.115~120 (2005)
  36. Mericske-Stern R, "In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants", Clin Oral Implants Res, 7, pp.153~161 (1996)
  37. Gervais MJ, "A rationale for retrievability of fixed, implant-supported prostheses: a complication-based analysis", Int J Prosthodont, 20, pp.13~24 (2007)
  38. Binon PP, "Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs", Int J Prosthodont, 8, pp.162~178 (1995)
  39. Binon PP, "The effect of implant", abutment hexagonal misfit on screw joint stability, 1996, pp.9, 149~160
  40. Burguete RL, "Tightening characteristics for screwed joints in osseointegrated dental implants", J Prosthet Dent, 71, pp.592~599 (1994)
  41. Sakaguchi RL, "Nonlinear contact analysis of preload in dental implant screws", Int J Oral Maxillofac Implants, 10, pp.295~302 (1995)
  42. Aboyoussef H, "Effect of an antirotation resistance form on screw loosening for single implantsupported crowns", J Prosthet Dent, 83, pp.450~455 (2000)
  43. Tan BF, "Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter", Int J Oral Maxillofac Implants, 19, pp.648~658 (2004)
  44. Duyck J, "Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study", J Oral Rehabil, 28, pp.226~233 (2001)
  45. Patterson EA, "Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants", Int J Oral Maxillofac Implants, 7, pp.26~33 (1992)
  46. Jaarda MJ, "Geometric comparison of five interchangeable implant prosthetic retaining screws", J Prosthet Dent, 74, pp.373~379 (1995)
  47. Wolfart M, "Retention forces and seating discrepancies of implant-retained castings after cementation", Int J Oral Maxillofac Implants, 21, pp.519~525 (2006)
  48. Mehl C, "Retrievability of implant-retained crowns following cementation", Clin Oral Implants Res, 19, pp.1304~1311 (2008)
  49. Singer A, "Cement-retained implant-supported fixed partial dentures: a 6-month to 3-year follow-up", Int J Oral Maxillofac Implants, 11, pp.645~649 (1996)
  50. Keller W, "Peri-implant microflora of implants with cemented and screw retained suprastructures", Clin Oral Implants Res, 9, pp.209~217 (1998)

관련 논문AI추천

Comparative study of abutment screw loosening with or without adhesive materialGholamreza Shirani, Mahnaz Arshad, Mohammadreza Rahimi Yeganeh, Sina Refoua대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제2호Influence of the implant abutment types and the dynamic loading on initial screw loosening김은숙, 신수연대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제1호Effect of cyclic loading and retightening on reverse torque value in external and internal implants박찬진, 조리라, 조웅래, 허윤혁대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호Influence of misfit direction and abutment type on torque loss and fracture strength of implant-supported fixed dental prosthesesDaniel Kules, Ieva Gendviliene, Ingrida Mischitz, Liudas Auškalnis, Maisa Haiek, Mutlu Özcan, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제6호Comparative study on stress distribution around internal tapered connection implants according to fit of cement-and screw-retained prostheses박은진, 박지만, 이미영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제3호Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading이주희, 차현석대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제6호

이 간행물의 다른 논문 (10건)