본문 바로가기
KERD
논문KCI 등재

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

초록

PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 μm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

Abstract

PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 μm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

참고문헌 (29)

  1. Brecker SC, "Porcelain baked to gold-A new medium in prosthodontics", J Prosthet Dent, 6, pp.801~810 (1956)
  2. Johnston JF, "The use and construction of gold crowns with a fused porcelain veneer-A progress report", J Prosthet Dent, 6, pp.811~821 (1956)
  3. Christensen GJ, "Longevity of posterior tooth dental restorations", J Am Dent Assoc, 136, pp.201~203 (2005)
  4. Miyazaki T, "A review of dental CAD", CAM: current status and future perspectives from 20 years of experience, 2009, pp.28, 44~56
  5. Weiss LE, "Rapid Prototyping in Europe and Japan", pp.5~20 (1997), Loyola College of Maryland
  6. Petzold R, "Rapid protyping technology in medicine-basics and applications", Comput Med Imaging Graph, 23, pp.277~284 (1999)
  7. Yadroitsev I, "Parametric analysis of the selective laser melting process", Appl Surf Sci, 253, pp.8064~8069 (2007)
  8. Gardner FM, "Margins of complete crowns-Literature review", J Prosthet Dent, 48, pp.396~400 (1982)
  9. Wataha JC, "Alloys for prosthodontic restorations", J Prosthet Dent, 87, pp.351~363 (2002)
  10. Wataha JC, "Casting alloys", Dent Clin North Am, 48, pp.499~512 (2004)
  11. Duncan JD, "The casting accuracy of nickel-chromium alloys for fixed prostheses", J Prosthet Dent, 47, pp.63~68 (1982)
  12. Ucar Y, "Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns", J Prosthet Dent, 102, pp.253~259 (2009)
  13. Regish KM, "Evaluation and comparison of the internal fit and marginal accuracy of base metal (nickelchromium) and zirconia copings before and after ceramic veneering: a sem study", Eur J Prosthodont Restor Dent, 21, pp.44~48 (2013)
  14. Eames WB, "Techniques to improve the seating of castings", J Am Dent Assoc, 96, pp.432~437 (1978)
  15. Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
  16. van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
  17. Beuer F, "Digital dentistry: an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
  18. Örtorp A, "The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study", Dent Mater, 27, pp.356~363 (2011)
  19. Quante K, "Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology", Dent Mater, 24, pp.1311~1315 (2008)
  20. Beuer F, "Marginal and internal fits of fixed dental prostheses zirconia retainers", Dent Mater, 25, pp.94~102 (2009)
  21. Laurent M, "Clinical evaluation of the marginal fit of cast crowns-validation of the silicone replica method", J Oral Rehabil, 35, pp.116~122 (2008)
  22. Sorensen JA, "A standardized method for determination of crown margin fidelity", J Prosthet Dent, 64, pp.18~24 (1990)
  23. Pelekanos S, "Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings", Eur J Esthet Dent, 4, pp.278~292 (2009)
  24. Rahme HY, "In vitro evaluation of the “replica technique” in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
  25. Council on Dental Materials and Devices, "Revised American National Standards Instititute", American Dental Association Specification No. 8 for Zinc Phosphate Cement, 1978, pp.96, 121~123
  26. Assif D, "The flow of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application", Quintessence Int, 18, pp.765~774 (1987)
  27. Hung SH, "Marginal fit of porcelain-fused-to-metal and two types of ceramic crown", J Prosthet Dent, 63, pp.26~31 (1990)
  28. Gulker I, "Margins", N Y State Dent J, 51, pp.213~215 (1985)
  29. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)

관련 논문AI추천

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography김동연, 김웅철, 김지환, 김총명, 김혜영대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and threedimensional replica techniques김기백, 김웅철, 김재홍, 김지환, 김혜영대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제2호Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processesFlorian Bernhard, Nadine Freifrau von Maltzahn, Philipp Kohorst대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제2호Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methodsÇağri Ural, Necati Kaleli, Yeşim Ölçer Us대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Comparison of prosthetic models produced by traditional and additive manufacturing methods김웅철, 김재홍, 김지환, 김혜영, 박진영대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems조진현, 하석준대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제6호

이 간행물의 다른 논문 (13건)