Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (μTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55°) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55°) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. μTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest μTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased μTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.
Abstract
PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (μTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55°) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55°) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. μTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest μTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased μTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.
참고문헌 (46)
- Azeem RA, "Clinical performance of direct versus indirect composite restorations in posterior teeth : A systematic review", J Conserv Dent, 21, pp.2~9 (2018)
- Alshehri SA, "An investigation into the role of core porcelain thickness and lamination in determining the flexural strength of In-Ceram dental materials", J Prosthodont, 20, pp.261~266 (2011)
- Mörmann WH, "Wear characteristics of current aesthetic dental restorative CAD", CAM materials: two-body wear, gloss retention, roughness and Martens hardness, 2013, pp.20, 113~125
- Zimmermann M, "Three-dimensional digital evaluation of the fit of endocrowns fabricated from different CAD", CAM materials, 2019, pp.28, e504~e509
- Coldea A, "Mechanical properties of polymer-infiltrated-ceramic-network materials", Dent Mater, 29, pp.419~426 (2013)
- Awada A, "Mechanical properties of resin-ceramic CAD", CAM restorative materials, 2015, pp.114, 587~593
- Lauvahutanon S, "Mechanical properties of composite resin blocks for CAD", CAM, 2014, pp.33, 705~710
- Della Bona A, "Characterization of a polymer-infiltrated ceramic-network material", Dent Mater, 30, pp.564~569 (2014)
- Gracis S, "A new classification system for all-ceramic and ceramic-like restorative materials", Int J Prosthodont, 28, pp.227~235 (2015)
- FDI World Dental Federation, "Repair of restorations: Adopted by the General Assembly: September 2019, San Francisco, United States of America", Int Dent J, 70, pp.7~8 (2020)
- Reston EG, "Repairing ceramic restorations: final solution or alternative procedure?", Oper Dent, 33, pp.461~466 (2008)
- Merve Bankoğlu Güngör, "Effect of surface treatments on shear bond strength of resin composite bonded to CAD", CAM resin-ceramic hybrid materials, 2016, pp.8(4), 259~266[DOI]
- Blum IR, "An in vitro comparison of four intra-oral ceramic repair systems", J Dent, 40, pp.906~912 (2012)
- Stawarczyk B, "Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD", CAM resin nanoceramic, 2015, pp.19, 299~308
- Kimyai S, "Effect of different mechanical and chemical surface treatments on the repaired bond strength of an indirect composite resin", Lasers Med Sci, 30, pp.653~659 (2015)
- Ozcan M, "Effect of surface conditioning methods on the microtensile bond strength of resin composite to composite after aging conditions", Dent Mater, 23, pp.1276~1282 (2007)
- Mehrsima Ghavami-Lahiji, "The effect of thermocycling on the degree of conversion and mechanical properties of a microhybrid dental resin composite", Restorative Dentistry and Endodontics, 43(2), pp.1~12 (2018), 대한치과보존학회
- Gale MS, "Thermal cycling procedures for laboratory testing of dental restorations", J Dent, 27, pp.89~99 (1999)
- Rinastiti M, "Effects of surface conditioning on repair bond strengths of nonaged and aged microhybrid, nanohybrid, and nanofilled composite resins", Clin Oral Investig, 15, pp.625~633 (2011)
- Wendler M, "Repair bond strength of aged resin composite after different surface and bonding treatments", Materials, 9, pp.E547~ (2016)
- Ataol AS, "Effects of surface treatments on repair bond strength of a new CAD", CAM ZLS glass ceramic and two different types of CAD, J Oral Sci, pp.2018, 60[DOI]
- Mokhtarpour F, "Effect of hydrofluoric acid surface treatments on micro-shear bond strength of CAD", CAM ceramics, 2017, pp.9, 5487~5493
- Barutcigil K, "Effect of different surface treatments on bond strength of resin cement to a CAD", CAM restorative material, 2019, pp.28, 71~78
- Kirmali O, "Efficacy of ceramic repair material on the bond strength of composite resin to zirconia ceramic", Acta Odontol Scand, 73, pp.28~32 (2015)
- Shiu P, "Effect of feldspathic ceramic surface treatments on bond strength to resin cement", Photomed Laser Surg, 25, pp.291~296 (2007)
- Kara HB, "Effect of different surface treatments on roughness of IPS Empress 2ceramic", Lasers Med Sci, 27, pp.267~272 (2012)
- Pinar Kursoglu, "Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface", The Journal of Advanced of Prosthodontics, 5(2), pp.98~103 (2013), 대한치과보철학회[DOI]
- Meryem Gulce Subası, "Repair bond strengths of non-aged and aged resin nanoceramics", The Journal of Advanced of Prosthodontics, 9(5), pp.364~370 (2017), 대한치과보철학회[DOI]
- Özel Bektas Ö, "Effect of thermocycling on the bond strength of composite resin to bur and laser treated composite resin", Lasers Med Sci, 27, pp.723~728 (2012)
- Demirtag Z, "Surface roughness of ceramicresin composites after femtosecond laser irradiation, sandblasting or acid etching and their bond strength with and without silanization to a resin cement", Oper Dent, 44, pp.156~167 (2019)
- Nihei T, "Dental applications for silane coupling agents", J Oral Sci, 58, pp.151~155 (2016)
- Elsaka SE, "Bond strength of novel CAD", CAM restorative materials to self-adhesive resin cement : the effect of surface treatments, 2014, pp.16, 531~540
- Yoshihara K, "Effectiveness and stability of silane coupling agent incorporated in ‘universal’adhesives", Dent Mater, 32, pp.1218~1225 (2016)
- Murillo-Gómez F, "Short-and long-term bond strength between resin cement and glass-ceramic using a silane-containing universal adhesive", Oper Dent, 42, pp.514~525 (2017)
- Sirisha K, "Validity of bond strength tests : A critical review-Part II", J Conserv Dent, 17, pp.420~426 (2014)
- Armstrong S, "Adhesion to tooth structure: a critical review of “micro” bond strength test methods", Dent Mater, 26, pp.e50~e62 (2010)
- Chaiyabutr Y, "Effect of abutment tooth color, cement color, and ceramic thickness on the resulting optical color of a CAD", CAM glass-ceramic lithium disilicate-reinforced crown, 2011, pp.105, 83~90
- Yilmaz B, "In vitro evaluation of color replication of metal ceramic specimens using visual and instrumental color determinations", J Prosthet Dent, 105, pp.21~27 (2011)
- Sasipin Lauvahutanon, "Discoloration of various CAD", CAM blocks after immersion in coffee, 2017, pp.42(1), 9~18[DOI]
- Alharbi A, "Stain susceptibility of composite and ceramic CAD", CAM blocks versus direct resin composites with different resinous matrices, 2017, pp.105, 162~169
- Acar O, "Color stainability of CAD", CAM and nanocomposite resin materials, 2016, pp.115, 71~75
- Shiozawa M, "Color stability of adhesive resin cements after immersion in coffee", Clin Oral Investig, 19, pp.309~317 (2015)
- Bagheri R, "Influence of food-simulating solutions and surface finish on susceptibility to staining of aesthetic restorative materials", J Dent, 33, pp.389~398 (2005)
- Nguyen JF, "Properties of experimental urethane dimethacrylate-based dental resin composite blocks obtained via thermo-polymerization under high pressure", Dent Mater, 29, pp.535~541 (2013)
- Stawarczyk B, "Discoloration of manually fabricated resins and industrially fabricated CAD", CAM blocks versus glass-ceramic:effect of storage media, duration, and subsequent polishing, 2012, pp.31, 377~383
- Lange RT, "Clinical evaluation of ceramic inlays compared to composite restorations", Oper Dent, 34, pp.263~272 (2009)
