본문 바로가기
KERD
논문KCI 등재

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with α-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

Abstract

PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with α-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

참고문헌 (58)

  1. Miyazaki T, "A review of dental CAD", CAM: current status and future perspectives from 20 years of experience, 2009, pp.28, 44~56
  2. Christensen GJ, "The state of fixed prosthodontic impressions:room for improvement", J Am Dent Assoc, 136, pp.343~346 (2005)
  3. Christensen GJ, "Impressions are changing: deciding on conventional, digital or digital plus in-office milling", J Am Dent Assoc, 140, pp.1301~1304 (2009)
  4. Mörmann WH, "The evolution of the CEREC system", J Am Dent Assoc, 137, pp.7S~13S (2006)
  5. "CAD/CAM dentistry and chairside digital impression making" (2009)[URL]
  6. Henkel GL, "A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions", Compend Contin Educ Dent, 28, pp.422~424 (2007)
  7. Garg AK, "Cadent iTero’s digital system for dental impressions:the end of trays and putty?", Dent Implantol Update, 19, pp.1~4 (2008)
  8. Schwartz IS, "A review of methods and techniques to improve the fit of cast restorations", J Prosthet Dent, 56, pp.279~283 (1986)
  9. Felton DA, "Effect of in vivo crown margin discrepancies on periodontal health", J Prosthet Dent, 65, pp.357~364 (1991)
  10. Grasso JE, "Effect of restoration quality on periodontal health", J Prosthet Dent, 53, pp.14~19 (1985)
  11. Richter WA, "Relationship of crown margin placement to gingival inflammation", J Prosthet Dent, 30, pp.156~161 (1973)
  12. Schwartz NL, "Unserviceable crowns and fixed partial dentures: life-span and causes for loss of serviceability", J Am Dent Assoc, 81, pp.1395~1401 (1970)
  13. Karlsson S, "A clinical evaluation of fixed bridges, 10 years following insertion", J Oral Rehabil, 13, pp.423~432 (1986)
  14. Council on dental materials and devices, "Revised American national standards institute", American dental association specification no. 8 for zinc phosphate cement, 1978, pp.96, 121~123
  15. Sorensen SE, "Gingival and alveolar bone reaction to marginal fit of subgingival crown margins", Scand J Dent Res, 94, pp.109~114 (1986)
  16. Christensen GJ, "Marginal fit of gold inlay castings", J Prosthet Dent, 16, pp.297~305 (1966)
  17. Ostlund LE, "Cavity design and mathematics: their effect on gaps at the margins of cast restorations", Oper Dent, 10, pp.122~137 (1985)
  18. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  19. McLean JW, "Polycarboxylate cements. Five years’ experience in general practice", Br Dent J, 132, pp.9~15 (1972)
  20. Gulker I, "Margins", NY State Dent J, 51, pp.213~215 (1985)
  21. Kydd WL, "Marginal leakage of cast gold crowns luted with zinc phosphate cement:an in vivo study", J Prosthet Dent, 75, pp.9~13 (1996)
  22. Wettstein F, "Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures", Eur J Oral Sci, 116, pp.272~279 (2008)
  23. White SN, "The three-dimensional effects of adjustment and cementation on crown seating", Int J Prosthodont, 6, pp.248~254 (1993)
  24. Grajower R, "Improving the fit of crowns with die spacers", J Prosthet Dent, 61, pp.555~563 (1989)
  25. Syrek A, "Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling", J Dent, 38, pp.553~559 (2010)
  26. Reich S, "Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD", CAM systems, 2005, pp.113, 174~179
  27. Rekow ED, "High-technology innovations-and limitations-for restorative dentistry", Dent Clin North Am, 37, pp.513~ (1993)
  28. Tinschert J, "Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD", CAM system, 2001, pp.26, 367~374
  29. Carter JM, "Punch shear testing of extracted vital and endodontically treated teeth", J Biomech, 16, pp.841~848 (1983)
  30. Strawn SE, "Spectroscopic changes in human dentine exposed to various storage solutions-short term", J Dent, 24, pp.417~423 (1996)
  31. Gemalmaz D, "Marginal fit changes during porcelain firing cycles", J Prosthet Dent, 73, pp.49~54 (1995)
  32. Hamaguchi H, "Marginal distortion of the porcelain- bonded-to-metal complete crown: an SEM study", J Prosthet Dent, 47, pp.146~153 (1982)
  33. Wang CJ, "Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation", J Prosthet Dent, 67, pp.786~790 (1992)
  34. 성지윤, "CAD", CAM system으로 제작한 zirconia core의 적합도, 2004, pp.42(5), 489~500[DOI]
  35. Gardner FM, "Margins of complete crowns-literature review", J Prosthet Dent, 48, pp.396~400 (1982)
  36. Fusayama T, "Relief of resistance of cement of full cast crowns", J Prosthet Dent, 14, pp.95~106 (1964)
  37. Eames WB, "Techniques to improve the seating of castings", J Am Dent Assoc, 96, pp.432~437 (1978)
  38. Weaver JD, "Marginal adaptation of castable ceramic crowns", J Prosthet Dent, 66, pp.747~753 (1991)
  39. White SN, "Effect of seating force on film thickness of new adhesive luting agents", J Prosthet Dent, 68, pp.476~481 (1992)
  40. Brukl CE, "Crown retention and seating on natural teeth with a resin cement", J Prosthet Dent, 53, pp.618~622 (1985)
  41. Syu JZ, "Influence of finish-line geometry on the fit of crowns", Int J Prosthodont, 6, pp.25~30 (1993)
  42. Pera P, "In vitro marginal adaptation of alumina porcelain ceramic crowns", J Prosthet Dent, 72, pp.585~590 (1994)
  43. Sorensen JA, "A standardized method for determination of crown margin fidelity", J Prosthet Dent, 64, pp.18~24 (1990)
  44. Moon BH, "A study on the marginal fit of all-ceramic crown using CCD camera", J Korean Acad Prosthodont, 36, pp.273~292 (1998)
  45. Leong D, "Marginal fit of machine-milled titanium and cast titanium single crowns", Int J Prosthodont, 7, pp.440~447 (1994)
  46. Molin M, "The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study", Acta Odontol Scand, 51, pp.201~206 (1993)
  47. Laurent M, "Clinical evaluation of the marginal fit of cast crowns-validation of the silicone replica method", J Oral Rehabil, 35, pp.116~122 (2008)
  48. Rahme HY, "In vitro evaluation of the “replica technique” in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
  49. Gassino G, "Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure", Int J Prosthodont, 17, pp.218~223 (2004)
  50. Groten M, "Determination of the minimum number of marginal gap measurements required for practical in-vitro testing", J Prosthet Dent, 83, pp.40~49 (2000)
  51. 윤종욱, "A study on the marginal fit of collarless metal ceramic fixed partial dentures", 대한치과보철학회지, 43(6), pp.707~716 (2005), 대한치과보철학회
  52. Vigolo P, "An in vitro evaluation of fit of zirconiumoxide-based ceramic four-unit fixed partial dentures, generated with three different CAD", CAM systems, before and after porcelain firing cycles and after glaze cycles, 2008, pp.17, 621~626
  53. Gonzalo E, "Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs", Int J Prosthodont, 22, pp.374~377 (2009)
  54. Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
  55. Jørgensen KD, "The relationship between the film thickness of zinc phosphate cement and the retention of veneer crowns", Acta Odontol Scand, 26, pp.169~175 (1968)
  56. Passon C, "The effect of multiple layers of die-spacer on crown retention", Oper Dent, 17, pp.42~49 (1992)
  57. Eames WB, "Elastomeric impression materials: effect of bulk on accuracy", J Prosthet Dent, 41, pp.304~307 (1979)
  58. Kunii J, "Effect of sintering on the marginal and internal fit of CAD", CAM-fabricated zirconia frameworks, 2007, pp.26, 820~826

관련 논문AI추천

Comparison of three-dimensional digital technique with twodimensional replica method for measuring marginal and internal fit of full coverage restorationsMahya Hasanzade, Marzieh Alikhasi, Naeime Moslemian, Soudabeh Koulivand대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicasAntonio Minarro Alonso, Estefania Aranda Yus, Josep Maria Anglada Cantarell대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제3호Evaluation of the marginal and internal fit of a single crown fabricated based on a threedimensional printed model장연, 김웅철, 김지환, 김혜영, 박종경, 심지영대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-freedigital impression techniquesAyşegül Güleryüz Gürbulak, Hasan Kocaağaoğlu, Haydar Albayrak, Sezgi Cinel Sahin대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제5호디지털 방식을 이용하여 제작한 전부지르코니아 수복물의 변연 적합도 평가강은숙, 김소연, 윤미정대한치과의사협회 · 대한치과의사협회지2018 · 제56권 제7호Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis안서영, 이경은, 이규복, 이두형, 이석재, 이청희, 정승미, Hang Nga Mai대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호

이 간행물의 다른 논문 (9건)